US$339.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 1878-2023: (Digital technical requirements for positron emission tomography devices) Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YY/T 1878-2023 | English | 339 |
Add to Cart
|
4 days [Need to translate]
|
(Digital technical requirements for positron emission tomography devices)
| Valid |
YY/T 1878-2023
|
Standard similar to YY/T 1878-2023
Basic data Standard ID | YY/T 1878-2023 (YY/T1878-2023) | Description (Translated English) | (Digital technical requirements for positron emission tomography devices) | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | Classification of International Standard | 11.040.50 | Word Count Estimation | 16,137 | Date of Issue | 2023-01-13 | Date of Implementation | 2024-07-15 | Issuing agency(ies) | State Drug Administration | Summary | This standard specifies the digital technical requirements for positron emission tomography devices. This standard applies to positron emission tomography imaging devices using digital technology. |
YY/T 1878-2023: (Digital technical requirements for positron emission tomography devices)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11.040.50
CCSC43
Pharmaceutical Industry Standard of the People's Republic of China
Digital technical requirements for positron emission tomography devices
Released on 2023-01-13
2024-07-15 Implementation
Released by the State Drug Administration
table of contents
Preface I
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Overview 1
5 Test items and test methods 2
5.1 Overview 2
5.2 Energy resolution 2
5.3 Time-of-flight resolution 2
5.4 SUV Accuracy 5
Appendix A (informative) Test methods for some items 8
Reference 14
Fig.1 Placement of time-of-flight resolution phantom 3
Figure 2 The shortest distance between the response line and the line source 4
Figure A.1 Schematic diagram of water model structure 9
Figure A.2 Schematic diagram of the position of the ball in the water mold 9
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by the State Drug Administration.
This document is prepared by the National Medical Electrical Appliances Standardization Technical Committee Radiotherapy, Nuclear Medicine and Radiation Dosimetry Equipment Standardization Sub-Technical Committee
Meeting (SAC/TC10/SC3) centralized.
This document was drafted by. Beijing Institute of Medical Device Inspection, Medical Device Technology Evaluation Center of the State Drug Administration, Hubei
Ruishi Digital Medical Imaging Technology Co., Ltd., Shanghai United Imaging Medical Technology Co., Ltd., Huazhong University of Science and Technology, Suzhou Ruipaining Technology Co., Ltd.
Ltd.
The main drafters of this document. Feng Jian, Gu Xiaofang, Liu Di, Li Bingxuan, Liu Shitao, Xiao Peng, Chen Xin, Zhang Bo.
Digital technical requirements for positron emission tomography devices
1 Scope
This document specifies the digital technical requirements for positron emission tomography (PET) devices.
This document applies to Positron Emission Tomography (hereinafter referred to as Digital PET) using digital technology.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
GB/T 17857-1999 Medical Radiology Terminology (Radiation Therapy, Nuclear Medicine and Radiation Dosimetry Equipment)
GB/T 18988.1-2013 Radionuclide Imaging Equipment Performance and Test Rules Part 1.Positron Emission Tomography
device
3 Terms and Definitions
The terms and definitions defined in GB/T 17857-1999 and GB/T 18988.1-2013 apply to this document.
4 Overview
The digitization mentioned in this document can be described as the conversion of continuous analog quantities into
Process of discrete digital quantities. Digital PET can be described as the energy information, time information and position information of a single event before coincidence.
All information is stored and processed in digitally coded PET.
PET digitization technology is based on digital signal processing hardware as a means to achieve accurate sampling of scintillation pulses.
a series of technologies. It may bring lower power consumption, more stable and superior performance, stronger scalability and adaptability.
PET digital technology is embodied in the process of signal sampling, which can convert the original analog signal into digital signal and output it. According to
The stage of converting the original analog signal into a digital signal in the sample circuit, the digitization of the PET signal is divided into the following two symbolic links. the electrical signal
Generation link (direct digitization after photoelectric conversion), single-event signal transmission link (before event coincidence). PET signal digitization technical requirements to
Meet at least one of the following.
a) Digitalization of single-event signal transmission
After the electrical pulse after photoelectric conversion is processed by analog circuit, the information of single event (position, time, energy, etc.)
Convert to digital signal and output.
b) Digitalization of electrical signal generation
The signal output by the photoelectric conversion device is directly digitized without analog signal processing. There are 4 technical solutions as follows.
---Directly digitize the electric pulse output by the analog optoelectronic device, and obtain the position, time and energy information of a single event;
---Digital sampling of the electrical pulse output by the analog optoelectronic device to obtain the original pulse waveform of a single event;
---Digital optoelectronic devices directly output digital single-event position, time, and energy information;
---Use digital optoelectronic devices to obtain digitized single-event original pulse waveform.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1878-2023_English be delivered?Answer: Upon your order, we will start to translate YY/T 1878-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 1878-2023_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1878-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|