4 days [Need to translate]
|
Guideline for measurement uncertainty evaluation of the certified values using the erythrocytes and leucocytes reference measurement procedures
| Valid |
YY/T 1825-2021
|
PDF similar to YY/T 1825-2021
Basic data | Standard ID | YY/T 1825-2021 (YY/T1825-2021) | | Description (Translated English) | Guideline for measurement uncertainty evaluation of the certified values using the erythrocytes and leucocytes reference measurement procedures | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C44 | | Word Count Estimation | 17,122 | | Issuing agency(ies) | State Drug Administration |
YY/T 1825-2021: Guideline for measurement uncertainty evaluation of the certified values using the erythrocytes and leucocytes reference measurement procedures ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guideline for measurement uncertainty evaluation of the certified values using the erythrocytes and leucocytes reference measurement procedures
ICS 11:100:10
CCSC44
People's Republic of China Pharmaceutical Industry Standard
Red blood cell and white blood cell count reference measurement procedure
Guidelines for the Evaluation of Measurement Uncertainty of Fixed Value Results
Published on 2021-12-06
2022-12-01 Implementation
Released by the State Drug Administration
foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents:
This document is proposed by the State Drug Administration:
This document is under the jurisdiction of the National Standardization Technical Committee for Medical Clinical Laboratory and In Vitro Diagnostic Systems (SAC/TC136):
This document is drafted by: Beijing Medical Device Inspection Institute, National Health Commission Clinical Inspection Center, Shanghai Clinical Inspection Center,
China National Accreditation Center for Conformity Assessment, Sysmex Medical Electronics (Shanghai) Co:, Ltd:, Shenzhen Mindray Biomedical Electronics Co:, Ltd:
Division, Beckman Coulter Trading (China) Co:, Ltd:
The main drafters of this document: Song Wei, Peng Mingting, Xu Chong, Fu Yue, Su Jing, Shi Xiaoyong, Li Jinzhi:
Red blood cell and white blood cell count reference measurement procedure
Guidelines for the Evaluation of Measurement Uncertainty of Fixed Value Results
1 Scope
This document gives guidelines for assessing the measurement uncertainty of the results of a reference measurement procedure for red blood cell and white blood cell counts:
This document applies to the measurement of the results of reference measurement procedures for the evaluation of red blood cell and white blood cell counts by reference measurement laboratories for blood cell analysis:
uncertainty:
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document:
GB/T 29791:1 Information provided by manufacturers of in vitro diagnostic medical devices (labeling) Part 1: Terms, definitions and general
Require
3 Terms and Definitions
The terms and definitions defined in GB/T 29791:1 and the following terms and definitions apply to this document:
3:1
referencemeasurementprocedure
Accepted as a measurement procedure that provides measurement results suitable for its intended use, including the evaluation of other
The correctness of measurement, calibration or assignment of reference substances to the values measured by the measurement procedure:
[Source: ISO 15193:2009, 3:7]
3:2
Type A evaluation of measurement uncertainty typeAevaluationofstandarduncertainty
Type A evaluation typeAevaluation
The evaluation of the measurement uncertainty component by the method of statistical analysis for the quantity measured under the specified measurement conditions:
[Source: JJF1001-2011, 5:20]
3:3
Type B assessment of measurement uncertainty typeBevaluationofstandarduncertainty
Type B evaluation typeBevaluation
An assessment of a measurement uncertainty component by a method other than the Type A assessment of measurement uncertainty:
Example: Rating based on the following information:
--- Quantity values issued by authoritative institutions;
--- Quantity of certified reference substances;
--- Calibration certificate;
--- instrument drift;
--- the accuracy level of the certified measuring instrument;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1825-2021_English be delivered?Answer: Upon your order, we will start to translate YY/T 1825-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 1825-2021_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1825-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|