YY/T 1771-2021: Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1771-2021English229 Add to Cart 3 days [Need to translate] Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery Valid YY/T 1771-2021

PDF similar to YY/T 1771-2021


Standard similar to YY/T 1771-2021

YY/T 1860.1   YY/T 1748   YY/T 1653   YY/T 1776   YY/T 1772   

Basic data

Standard ID YY/T 1771-2021 (YY/T1771-2021)
Description (Translated English) Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Word Count Estimation 12,111
Issuing agency(ies) State Drug Administration

YY/T 1771-2021: Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery ICS 11.040.40 C35 People's Republic of China Pharmaceutical Industry Standards Bend-free recovery method to test the shape of nickel-titanium Memory alloy phase transition temperature Released on 2021-03-09 2022-04-01 implementation Issued by the National Medical Products Administration

Table of contents

Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Abbreviations 2 5 Overview of test methods 2 6 Significance and Application 2 7 Instrument 2 8 Sample 4 9 Metering 4 10 Procedure 4 11 Measurement of phase transition temperature 6 12 Report 7 Appendix A (informative appendix) Theoretical basis 8 Appendix B (informative appendix) Schematic diagram of non-contact vision test system 9

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of the National Standardization Technical Committee for Surgical Implants and Orthopaedic Devices (SAC/TC110). Drafting organizations of this standard. Tianjin Medical Device Quality Supervision and Inspection Center, Medical Device Technology Review under the State Drug Administration Xin, Jiangyin Fastenpel New Material Technology Co., Ltd., Shanghai MicroPort Medical Equipment (Group) Co., Ltd., and Research Medical Equipment (Beijing) have Limited company. The main drafters of this standard. Ma Chunbao, Zhang Chen, Guo Xiaolei, Aruhan, Chen Qingfu, Wang Lingling, Sun Bing, Hu Tianzhou, Yuan Zhishan, Li Juntao. Bend-free recovery method to test the shape of nickel-titanium Memory alloy phase transition temperature

1 Scope

This standard specifies a test method for determining the transformation temperature of martensite to austenite by measuring the deformation recovered during the thermal conversion process. This standard applies to nickel-titanium alloys that are fully annealed or heat-treated. Note. This standard is not an attempt to explain all the safety issues involved, even those related to its use. Establish proper safety and Health regulations, as well as the applicability of clear management restrictions prior to application, are the responsibility of the users of this standard.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. YS/T 1064-2015 Nitinol shape memory alloy terminology

3 Terms and definitions

The terms and definitions defined in YS/T 1064-2015 and the following are applicable to this document. 3.1 Freerecovery The shape memory alloy deformed by the low-temperature phase transforms into austenite during the heating process, and has free and unconstrained recovery action. 3.2 95% recovery deformation austenite finish temperature 95percentrecoverabledeformationaustentitefinishtemperature Af-95 The austenite of the bent and freely recovered finished wire, finished pipe or finished part measured by the method of recoverable deformation up to 95% The end temperature of the transition. 3.3 Tangent method austenite finish temperature tangentmethodaustentitefinishtemperature Af-tan The end temperature of austenite transformation of the finished wire, finished pipe or finished part that is bent and freely recovered by the tangent method. 3.4 R'phase start temperature R'-phasestarttemperature Rs' In the heating process of two-stage transformation, the starting temperature of martensite transformation into R phase. 3.5 R'phase finish temperature R'-phasefinishtemperature Rf' In the heating process of the two-stage transformation, the martensite transforms to the completion temperature of the R phase.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1771-2021_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1771-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1771-2021_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1771-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.