HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY/T 1715-2020 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 1715-2020: Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia(Y-TZP)
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1715-2020English259 Add to Cart 3 days [Need to translate] Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia(Y-TZP) Valid YY/T 1715-2020

PDF similar to YY/T 1715-2020


Standard similar to YY/T 1715-2020

YY/T 1860.1   YY/T 1748   YY/T 1705   YY/T 1706.1   

Basic data

Standard ID YY/T 1715-2020 (YY/T1715-2020)
Description (Translated English) Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia(Y-TZP)
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Classification of International Standard 11.040.40
Word Count Estimation 14,192
Date of Issue 2020-06-30
Date of Implementation 2021-06-01
Issuing agency(ies) State Drug Administration

YY/T 1715-2020: Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia(Y-TZP)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia(Y-TZP) ICS 11.040.40 C35 People's Republic of China Pharmaceutical Industry Standard Yttrium oxide stabilized tetragonal zirconia (Y-TZP) ceramic material for surgical implants 2020-06-30 released 2021-06-01 implementation Issued by the State Drug Administration

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the redrafting method to modify and adopt ISO 13356.2015 "Surgical Implant Yttrium Oxide Stabilized Tetragonal Zirconia (Y-TZP) Ceramic Material". This standard has made editorial changes to the structure of Chapter 3 in accordance with the rules of GB/T 1.1-2009, adding the article number "3.1 General". Compared with ISO 13356.2015, this standard has the following technical differences. --- "Scope" (see Chapter 1) added "This standard applies to yttria stabilized tetragonal zirconia (Y-TZP) ceramic materials for surgical implants"; --- Regarding normative references, this standard has made adjustments with technical differences to adapt to my country's technical conditions and adjustments. The situation is collectively reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows. ● Replace ISO 3310-1 with GB/T 6003.1 modified to adopt international standards; ● Replace ISO 14704 with GB/T 6569 modified to adopt international standards; ● Replace ISO 14705 with GB/T 16534 modified to adopt international standards; ● Replace ISO 7500-1.2004 with GB/T 16825.1-2008 which is equivalent to the international standard; ● Replace ISO 18754 with GB/T 25995 modified to adopt international standards. Please note that certain contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of the National Standardization Technical Committee for Surgical Implants and Orthopedic Devices (SAC/TC110). This standard was drafted. Tianjin Medical Device Quality Supervision and Inspection Center, Tsinghua University Nuclear and New Energy Technology Research Institute, Beijing Gusheng Biotechnology Co., Ltd. The main drafters of this standard. Ma Chunbao, An Junbo, Tian Jimo, Wang Chen, Zhang Lin, Cao Xiaogang. Surgical implants yttria stabilized tetragonal zirconia (Y-TZP) ceramic material

1 Scope

This standard specifies the biocompatible and biostable yttria-stabilized tetragonal zirconia for surgical implants Crystal, Y-TZP) ceramic bone substitute material requirements and corresponding test methods. This standard applies to yttria stabilized tetragonal zirconia (Y-TZP) ceramic materials for surgical implants.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document. GB/T 6003.1 Test sieve technical requirements and inspection Part 1.Metal wire woven mesh test sieve (GB/T 6003.1-2012, ISO 3310-1..2000, MOD) GB/T 6569 Test method for bending strength of fine ceramics (GB/T 6569-2006, ISO 14704.2000, MOD) GB/T 16534 Room temperature hardness test method for fine ceramics (GB/T 16534-2009, ISO 14705.2008, MOD) GB/T 16825.1-2008 Inspection of static uniaxial testing machine Part 1.Inspection and calibration of force measuring system of tensile and (or) compression testing machine (ISO 7500-1.2004, IDT) GB/T 25995 Fine ceramic density and apparent porosity test method (GB/T 25995-2010, ISO 18754.2003, MOD) ISO 3611 Product Geometric Technical Specification (GPS) Dimensional Measuring Equipment. External Micrometer Measurement Design and Metrological Characteristics ISO 13383-1 Fine ceramics (advanced ceramics, high-tech ceramics) Microstructure characteristics Part 1.Determination of grain size and size distribution ISO 17561 Fine ceramics (advanced ceramics, high-tech ceramics) Test method for measuring the elastic modulus of bulk ceramics by acoustic resonance at room temperature ISO 20501 Weibull statistics of the strength data of fine ceramics (advanced ceramics, high-tech ceramics) ISO 22214 Fine ceramics (advanced ceramics, high-tech ceramics) cyclic bending fatigue test method for bulk ceramics at room temperature

3 Physical and chemical properties

3.1 General When performing physical and chemical performance tests according to Chapter 4, its performance should meet the requirements of Table 1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1715-2020_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1715-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1715-2020_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1715-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.