HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY/T 1621-2018 English PDF

US$235.00 · In stock
Delivery: <= 0 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 1621-2018: Medical carbon dioxide incubator
Status: Valid

YY/T 1621: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1621-2018English235 Add to Cart 0--9 seconds. Auto-delivery Medical carbon dioxide incubator Valid YY/T 1621-2018
YY/T 1621-2018English235 Add to Cart 0--9 seconds. Auto-delivery Medical carbon dioxide incubator Valid YY/T 1621-2018

PDF similar to YY/T 1621-2018


Standard similar to YY/T 1621-2018

YY/T 1652   YY/T 1582   YY/T 1200   YY/T 1183   

Basic data

Standard ID YY/T 1621-2018 (YY/T1621-2018)
Description (Translated English) Medical carbon dioxide incubator
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.100
Word Count Estimation 15,146
Date of Issue 2018-09-28
Date of Implementation 2020-04-01
Issuing agency(ies) State Drug Administration
Summary This standard specifies the terms and definitions, requirements, test methods, labels, packaging marks and instructions for use, packaging, transportation and storage of medical carbon dioxide incubators. This standard applies to medical carbon dioxide incubators for culturing human-derived samples such as biological cells, tissues and bacteria in clinical tests. The upper limit of the cultivation temperature of the incubator applicable to this standard is 55��C, the lower limit of the temperature is 3��C to 5��C higher than the ambient temperature, the control range of carbon dioxide concentration is 0% to 20%, and the internal volume is 100L to 300L.

YY/T 1621-2018: Medical carbon dioxide incubator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11:100 C44 Pharmaceutical Industry Standard of the People's Republic of China YY 1621-2018 Medical carbon dioxide incubator According to the State Drug Administration medical device industry Standard Announcement (No: 76 of 2022), this standard is from From September 7, 2022, it will be converted into a recommended standard, no Enforce it again: Released on:2018-09-28 2020-04-01 Implementation Released by the State Drug Administration

table of contents

Preface I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Requirements 1 5 Test method 3 6 Labels, packaging labels and instructions for use 5 7 Packaging, transportation and storage 6 Appendix A (Normative Appendix) Temperature Control Performance Test Method 7 Appendix B (Normative) Carbon dioxide concentration control performance test method 10 YY 1621-2018

foreword

All technical contents of this standard are mandatory: This standard is drafted in accordance with the rules given in GB/T 1:1-2009: Please note that some contents of this document may refer to patents: The issuing agency of this document assumes no responsibility for identifying these patents: This standard was proposed by the State Drug Administration: This standard is prepared by the National Measurement, Control and Laboratory Electrical Equipment Safety Standardization Technical Committee Medical Equipment Sub-Technical Committee (SAC/ TC338/SC1) centralized: This standard was drafted by: Beijing Institute of Medical Device Inspection, Shanghai Lishen Scientific Instrument Co:, Ltd:, Thermo Fisher Scientific (China) Co:, Ltd: Co:, Ltd:, Qingdao Haier Special Electric Co:, Ltd:, Bidi Medical Devices (Shanghai) Co:, Ltd:, Peking University Third Hospital: The main drafters of this standard: Liu Pei, Wu Jun, Shen Ping, Li Chunjing, Peng Xuguang, Cao Qing, Jiang Ahong, Xu Heng: YY 1621-2018 Medical carbon dioxide incubator

1 Scope

This standard specifies the terms and definitions, requirements, test methods, labels, and packaging labels for medical carbon dioxide incubators (hereinafter referred to as incubators): identification and instructions for use, packaging, transport and storage: This standard applies to medical carbon dioxide incubators for culturing human-derived samples such as biological cells, tissues and bacteria in clinical tests: Book The upper limit of the culture temperature of the standard applicable incubator is 55°C, the lower limit of the temperature is 3°C~5°C higher than the ambient temperature, and the carbon dioxide concentration is controlled The range is 0%~20%, and the internal volume is 100L~300L:

2 Normative references

The following documents are indispensable for the application of this document: For dated references, only the dated version applies to this document pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 191 Packaging, storage and transportation icon marks GB 4793:1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements GB 4793:6 Safety requirements for electrical equipment for measurement, control and laboratory use Part 6: Characteristics of laboratory material heating equipment special request GB/T 14710 Environmental requirements and test methods for medical electrical appliances GB/T 18268:1 Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1: General Requirements YY/T 0466:1 Symbols for Medical Device Labeling, Marking and Information Provision for Medical Devices Part 1: General Requirements

3 Terms and Definitions

The following terms and definitions apply to this document: 3:1 The temperature range within which the incubator can be effectively controlled when operating under specified environmental conditions: 3:2 working space working space The space area in the studio that meets the specified technical conditions: 3:3 chamber temperature The temperature at the geometric center of the workspace:

4 requirements

4:1 Working environment conditions If the manufacturer has no special working environment requirements, the working environment of the incubator shall meet the following requirements: a) Ambient temperature: 18°C~30°C; YY 1621-2018

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1621-2018_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1621-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1621-2018_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1621-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY/T 1621-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 1621-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.