HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Sep 2024)

YY/T 1560-2017 English PDF

YY/T 1560-2017 (YY/T1560-2017, YYT 1560-2017, YYT1560-2017)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1560-2017English439 Add to Cart 5 days [Need to translate] Spinal implant—Standard test methods for occipital-cervical and occipital-cervical-thoracic implant constructs in a vertebrectomy model Valid YY/T 1560-2017
Standards related to: YY/T 1560-2017

BASIC DATA
Standard ID YY/T 1560-2017 (YY/T1560-2017)
Description (Translated English) Spinal implant--Standard test methods for occipital-cervical and occipital-cervical-thoracic implant constructs in a vertebrectomy model
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Classification of International Standard 11.040.40
Word Count Estimation 22,246
Date of Issue 2017-03-28
Date of Implementation 2018-04-01
Drafting Organization Tianjin Medical Device Quality Supervision and Inspection Center, Changzhou Osmanthus Medical Devices Co., Ltd., Shandong Weigao Orthopedic Materials Co., Ltd., Medtronic (Shanghai) Management Co., Ltd.
Administrative Organization National Surgical Implants and Orthopedic Instruments Standardization Technical Committee Orthopedic Implants Sub-Technical Committee (AC/TC 110/SC 1)
Proposing organization China Food and Drug Administration
Issuing agency(ies) State Food and Drug Administration

YY/T 1560-2017 Spinal implant-Standard test methods for occipital-cervical and occipital-cervical-thoracic implant constructs in a vertebrectomy model ICS 11.040.40 C35 People's Republic of China pharmaceutical industry standards Spine implants in vertebral body excision models Pillow neck and occipito - cervical implant test methods Spinalimplant-Standardtestmethods foroccipital-cervicaland 2017-03-28 Posted 2018-04-01 implementation State Food and Drug Administration released Foreword This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the State Food and Drug Administration. This standard by the National Surgical implants and orthopedic instruments Standardization Technical Committee Orthopedic Implants Sub-Technical Committee (SAC/TC110 / SC1) centralized. This standard was drafted unit. Tianjin Medical Device Quality Supervision and Inspection Center, Changzhou Osmai Medical Devices Co., Ltd., Shandong Wei high bone Branch Materials Co., Ltd., Medtronic (Shanghai) Management Co., Ltd. The main drafters of this standard. Zhao Binghui, King Ming, Chen Changsheng, Wang Jian, Lu Chenglin, Gu Ying Song, Yang Haijun, Guo Yujia. Spine implants in vertebral body excision models Pillow neck and occipito - cervical implant test methods 1 Scope This standard specifies the materials and methods of static and fatigue tests of the occipitocervix and occipito-cervical implant components in a vertebral body excision model. most The test material for the occipitoccipital and occipito-cervical implant components depends on the intended site of implantation and the method of application. This test method is intended to provide a basis for the comparison of the mechanical properties of occipitoccipital and occipito-cervical implant components in the past, present and future, The method can be used to compare the occipito-cervical and occipito-cervical thoracic implants that are expected for different application sites and methods of application. The purpose of these test methods It is not intended to define the performance level as there is not enough information to predict the outcome of an implant. This standard provides guidelines for loading types and loading methods and provides for the comparative evaluation of occipitoccipital and occipito-cervical implant components three Static test methods and two fatigue test methods. This test method is to measure the displacement, determine the yield load and evaluate the occipital or occipitocervix The rigidity and strength of the implant assembly establish the guiding principle. Some occipito-cervical or occipito-cervical implants may not be suitable for use in accordance with this standard Test configuration for testing. This standard is not intended to address all the safety issues involved, even those related to their use safety issues. establish Appropriate safety and health practices, as well as the applicability of a clear management limit before application, are the sole responsibility of the user of this standard. 2 Normative references The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 16825.1 static uniaxial testing machine test Part 1. Tensile and (or) pressure testing machine testing system and force measurement calibration YY/T 0857 vertebral excision model of spinal implant test methods Spinal implant interbody fusion cage mechanical properties test method 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Longitudinal part of the working length activelengthofthelongitudinalelement The linear distance between the center of rotation of the test block. 3.2 Arm blockmomentarm Vertical line from the point where the screw is inserted to the hinge pin axis. 3.3 Compression or tensile bending stiffness compressiveortensilebendingstiffness Compression or tensile bending yield load divided by the elastic displacement (see Figure 1, the initial slope of BC). ...