YY/T 1448-2016: Lipoprotein(a) test reagent
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1448-2016English179 Add to Cart 3 days [Need to translate] Lipoprotein(a) test reagent Valid YY/T 1448-2016

PDF similar to YY/T 1448-2016


Standard similar to YY/T 1448-2016

YY/T 1515   YY/T 1516   YY/T 1514   YY/T 1443   YY/T 1442   

Basic data

Standard ID YY/T 1448-2016 (YY/T1448-2016)
Description (Translated English) Lipoprotein(a) test reagent
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.110
Word Count Estimation 9,917
Date of Issue 2016-01-26
Date of Implementation 2017-01-01
Quoted Standard YY/T 0466.1
Regulation (derived from) China Food and Drug Administration Bulletin 2016 No.25
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the requirements, test methods, labeling, labeling and instructions for use of the lipoprotein (a) assay kit, packaging, transport and storage requirements. This standard applies to the use of immunoturbidimetry (transmission method) on human serum or plasma lipoprotein (a) quantitative detection of the kit, including manual reagents and semi-automatic, fully automated biochemical analyzer used in the reagent.

YY/T 1448-2016: Lipoprotein(a) test reagent

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Lipoprotein (a) test reagent ICS 11.110 C44 People's Republic of China Pharmaceutical Industry Standard Lipoprotein (a) assay kit 2016-01-26 release 2017-01-01 Implementation State Food and Drug Administration issued

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The release of this document The Agency does not assume responsibility for identifying these patents. This standard is proposed by the State Food and Drug Administration. This standard by the National Medical Laboratory Laboratory and in vitro diagnostic system Standardization Technical Committee (SAC/TC136) centralized. The drafting of this standard. Beijing Medical Devices Testing Institute, Beijing nine strong biotechnology Co., Ltd., Beijing Leadman Biochemical shares Co., Ltd., Zhongsheng North Control Biotechnology Co., Ltd., Sichuan Mike Technology Biology Co., Ltd. The main drafters of this standard. Bi Chunlei, Huang Yan, Liu Bingzhong, Wang Yunfeng, Dragon Teng, Du Haiou. Lipoprotein (a) assay kit

1 Scope

This standard specifies the requirements, test methods, labeling, labeling and instructions for use of the lipoprotein (a) assay kit, packaging, transport and storage And so on. This standard applies to the use of immunoturbidimetry (transmission method) on human serum or plasma lipoprotein (a) quantitative detection kit, package Including hand reagents and reagents used in semi-automatic, fully automated biochemical analyzers.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. YY/T 0466.1 Symbols for medical devices for labeling, labeling and providing information on medical devices - Part 1. General requirements

3 request

3.1 appearance Should specify the normal appearance requirements. 3.2 Capacity Should not be less than the marked value. 3.3 Reagent Blank Absorbance Should specify the reagent blank absorbance requirements. 3.4 Analysis of sensitivity When measuring.200 mg/L lipoprotein (a), the absorbance difference (ΔA) should be not less than 0.04. 3.5 Linearity The linear range of the kit should cover [100,800] mg/L. a) The linear correlation coefficient (r) should be not less than 0.990; b) [100,200] mg/L interval, the linear deviation should not exceed ± 20mg/L; (200,800] mg/L interval, the linear deviation Should not exceed ± 10%. 3.6 precision 3.6.1 Repeatability Repeated test (300 ± 100) mg/L of human serum or control substance, the results of the coefficient of variation CV (%) should not be greater than 4%.