YY/T 1426.2-2016: Implants for surgery. Wear of total knee-joint prostheses. Part 2: Methods of measurement
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1426.2-2016English114 Add to Cart 3 days [Need to translate] Implants for surgery. Wear of total knee-joint prostheses. Part 2: Methods of measurement Valid YY/T 1426.2-2016

PDF similar to YY/T 1426.2-2016


Standard similar to YY/T 1426.2-2016

YY/T 1705   YY/T 1653   YY/T 1137   YY/T 1426.3   YY/T 1428   YY/T 1429   

Basic data

Standard ID YY/T 1426.2-2016 (YY/T1426.2-2016)
Description (Translated English) Implants for surgery. Wear of total knee-joint prostheses. Part 2: Methods of measurement
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Classification of International Standard 11.040.40
Word Count Estimation 6,654
Date of Issue 2016-01-26
Date of Implementation 2017-01-01
Quoted Standard ISO 14243-1
Adopted Standard ISO 14243-2-2009, IDT
Regulation (derived from) China Food and Drug Administration Bulletin 2016 No.25
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the method of assessing the tibial component wear of the general knee joint by weight analysis after total knee prosthesis wear test in accordance with Part 1.

YY/T 1426.2-2016: Implants for surgery. Wear of total knee-joint prostheses. Part 2: Methods of measurement


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Implants for surgery.Wear of total knee-joint prostheses.Part 2. Methods of measurement ICS 11.040.40 C35 People's Republic of China Pharmaceutical Industry Standard Peripheral prosthesis wear in surgical implants Part 2. Methods of measurement Part 2. Methodsofmeasurement (ISO 14243-2..2009, IDT) 2016-01-26 release 2017-01-01 Implementation State Food and Drug Administration issued Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1

4 gravimetric method

5 Test Report 3

Foreword

YY/T 1426 "Surgical implants per knee prosthesis wear" is divided into three parts. - Part 1. Load and displacement parameters of load control wear testing machines and associated test environmental conditions; - Part 2. Methods of measurement; Part 3. Load and displacement parameters of displacement control wear testing machines and associated test environmental conditions. This part is part 2 of YY/T 1426. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the translation method equivalent to ISO 14243-2..2009 "Surgical implants of the knee joint prosthesis wear Part 2. Quantity method ". In this part of the normative reference to the international documents have a consistent correspondence between the following documents. - YY/T 1426.1-2016 Surgical implants for wear of total knee prostheses Part 1. Wear test for wear control Load and displacement parameters of the machine and associated test environmental conditions (ISO 14243-1..2009, IDT). Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This section is proposed by the State Food and Drug Administration. This section is organized by the National Committee for the Standardization of Surgical Implants and Orthopedic Instruments Orthopedic Implants Subcommittee (SAC/TC110 / SC1). This part of the drafting unit. the State Food and Drug Administration Tianjin Medical Device Quality Supervision and Inspection Center, Xi'an Jiaotong University. This part of the main drafters. Jiao Yongzhe, Dong Shuangpeng, Wang Ling, Hou Yinhui. Peripheral prosthesis wear in surgical implants Part 2. Methods of measurement

1 Scope

This part of YY/T 1426 specifies the use of weight analysis to evaluate the total knee after total knee prosthesis wear test in accordance with Part 1 The method of wear of tibial parts of joint prosthesis.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. ISO 14243-1 Surgical implants - Wear of the general knee prosthesis - Part 1. Load and wear of the load - controlled wear test machine. Shift parameters and associated environmental conditions (Implantsforsurgery-Wearoftotalknee-jointprostheses-Part 1. Loadinganddisplacementparametersforwear-testingmachineswithloadcontrolandcorresponding environmentalconditionsfortests

3 terms and definitions

The following terms and definitions apply to this document. 3.1 Wear wear Due to the relative movement between the prosthetic component components and the load caused by the loss of component material.

4 weight analysis

4.1 Principles The test sample is soaked in the lubricating fluid and repeatedly removed from the lubricating fluid, washed, dried and weighed until the liquid absorption rate reaches Stability value. The test sample was mounted on a knee joint simulator for a wear test to measure the quality loss of the test sample due to wear. The control samples were soaked in the same lubricating medium medium with no or no load and no relative motion, so that the control sample was drawn And the same treatment procedure is used to achieve the purpose of the control. 4.2 Reagents and materials 4.2.1 Liquid test media, according to ISO 14243-1. 4.2.2 Control samples according to ISO 14243-1. 4.2.3 isopropanol. 4.3 Instruments 4.3.1 Balance. The range meets the mass range of the test sample with an accuracy of ± 0.1 mg.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1426.2-2016_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1426.2-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1426.2-2016_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1426.2-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.