YY/T 1408-2016: Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1408-2016English259 Add to Cart 3 days [Need to translate] Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph Valid YY/T 1408-2016

PDF similar to YY/T 1408-2016


Standard similar to YY/T 1408-2016

YY/T 1694   YY/T 1711   YY/T 1537   YY/T 1417   YY/T 1407   

Basic data

Standard ID YY/T 1408-2016 (YY/T1408-2016)
Description (Translated English) Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C43
Classification of International Standard 11.040.50
Word Count Estimation 13,124
Date of Issue 2016-03-23
Date of Implementation 2017-01-01
Regulation (derived from) Notice of the General Administration of Food and Drug Administration (No. 74 of 2016)
Issuing agency(ies) State Food and Drug Administration

YY/T 1408-2016: Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Performance characteristics and test methods of imaging system of single photon emission and X-ray computed tomograph ICS 11.040.50 C43 People's Republic of China Pharmaceutical Industry Standard Single photon emission and X - ray computed tomography System performance and test methods Performancecharacteristics andtestmethodsofimagingsystemofsinglephoton 2016-03-23 release 2017-01-01 Implementation State Food and Drug Administration issued Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 Performance and test methods Appendix A (informative) NEMA Standard Publication NU1-2007 "Single Photon Emission Tomography Imaging Performance Test" 8

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This standard is proposed by the State Food and Drug Administration. This standard by the National Medical Electrical Appliances Standardization Technical Committee of Radiation Therapy, Nuclear Medicine and Radiation Dosing Equipment Subcommittee (SAC/TC10/SC3). The drafting of this standard. Beijing Medical Device Testing Institute, Shanghai Yingying Medical Technology Co., Ltd., General Electric Medical System Trade (Shanghai) Co., Ltd., Siemens (China) Co., Ltd., Philips (China) Investment Co., Ltd., Liaoning Province, medical equipment testing. The main drafters of this standard. Feng Jian, Chen Mu, Meng Fanbo, Nie Tao, Yu Bin, Miao Bin, Li Zhizhuo, Wang Yunshan.

Introduction

Performance and test methods for single photon emission tomography in single photon emission and X-ray computed tomography systems GB/T 18989-2013, GB/T 18988.2-2013, GB/T 18988.3-2013 related content, X-ray computed tomography Like part of the performance and test methods cited YY/T 0310-2015 related content. GB/T 18988.2-2013, GB/T 18988.3-2013, GB/T 18989-2013 were modified using IEC 61675-2. 1998, IEC 61675-3..1998, IEC 60789..1992. At present, the production sites of the major manufacturers of radionuclide imaging equipment are located in the United States, its reported parameters, data processing software, Test body are the American Electrical Manufacturers Association (NEMA) as the basis for the design basis, there are manufacturers using IEC standards. For that In the government, enterprises and medical institutions to understand and use these products IEC and NEMA two series of standards, the NEMA standard Publication Contents NU1-2007 "Single Photon Emission Tomography Imaging Performance Test" is included as an informative Appendix A. As the IEC standard and NEMA standards in the test requirements, test methods, there are some differences, the use of the mold, test conditions, testing Location, calculation methods are different, so the two standard test items can not be compared between each other, it is recommended that the standard user a complete reference to two Any kind of method, not cross the use. Single photon emission and X - ray computed tomography System performance and test methods

1 Scope

This standard specifies the performance and testing of single photon emission and X-ray computed tomography systems (hereinafter referred to as "SPECT/CT") method. This standard applies to SPECT/CT, does not apply to independent single photon emission tomography (hereinafter referred to as "SPECT") and independent X-ray computed tomography equipment (hereinafter referred to as "CT").

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 17857-1999 Medical radiology terminology (Radiation therapy, nuclear medicine and radiation dosimetry equipment) GB/T 18988.2-2013 Radionuclide imaging equipment Performance and test rules - Part 2. Single photon emission computed Layer imaging device GB/T 18988.3-2013 Radionuclide imaging equipment Performance and test rules - Part 3. Gamma camera body imaging system GB/T 18989-2013 Radionuclide imaging equipment Performance and test rules Gamma camera General technical requirements for X - ray computed tomography equipment YY/T 0310-2015

3 terms and definitions

GB/T 17857-1999, GB/T 18988.2-2013, GB/T 18988.3-2013, GB/T 18989-2013, YY/T 0310- 2015 and the following terms and definitions apply to this document. 3.1 Image registration imageregistration The process of transforming different image datasets to the same coordinate system. Different image data sets refer to different times and/or different pattern pairs An object is acquired by the acquired data set.

4 performance and test methods

4.1 SPECT performance and test methods 4.1.1 Overview If the user is required to refer to the method of Appendix A, it is recommended that the contents of this chapter and Appendix A should not be cross-referenced. 4.1.2 System plane sensitivity According to GB/T 18989-2013 3.1 in the test method specified.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1408-2016_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1408-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1408-2016_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1408-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.