YY/T 1229-2014: Calcium test reagent kit
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1229-2014English259 Add to Cart 3 days [Need to translate] Calcium test reagent kit Valid YY/T 1229-2014

PDF similar to YY/T 1229-2014


Standard similar to YY/T 1229-2014

YY/T 1232   YY/T 1235   YY/T 1231   YY/T 1233   YY/T 1226   YY/T 1222   

Basic data

Standard ID YY/T 1229-2014 (YY/T1229-2014)
Description (Translated English) Calcium test reagent kit
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.100
Word Count Estimation 11,168
Date of Issue 6/17/2014
Date of Implementation 7/1/2015
Quoted Standard GB 3100; YY/T 0316; YY/T 0466.1
Regulation (derived from) China Food and Drug Administration in 2014 Bulletin No. 30
Issuing agency(ies) State Food and Drug Administration
Summary This Standard applies to the use of calcium Arsenazo �� law, o copper phthalocyanine complex method, methyl thymol blue method for serum, plasma and other body fluids calcium quantitative detection of the assay reagent (box), including manual reagents and

YY/T 1229-2014: Calcium test reagent kit

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calcium test reagent kit ICS 11.100 C44 People's Republic of China pharmaceutical industry standards Calcium assay reagent (kit) Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national medical clinical laboratory testing and in vitro diagnostic systems for Standardization Technical Committee (SAC/TC136) centralized. This standard was drafted. Beijing Medical Device Testing, Shanghai Fuxing Changzheng Medical Science Co., Beckman Coulter commerce (in Country) Co., InTec (Xiamen) Technology Co., Ltd., Hitachi High-Technologies (Shanghai) International Trade Co., Ltd. Beijing Branch. The main drafters of this standard. Yangzong Bing, Wu Jie, Liu Chiu, Du Jiao, Zhang Yongmei, Duhai Ou. Calcium assay reagent (kit)

1 Scope

This standard specifies the calcium assay reagent (kit) requirements, test methods, labels, brochures, packaging, transportation and storage. This standard applies to the use of azo arsenic Ⅲ law, o-cresol copper phthalocyanine complex method, methyl thymol blue method for serum, plasma and other body fluids calcium intake Calcium row quantitative detection assay reagent (kit), including manual reagents and on the semi-automatic biochemical analyzer used. This standard does not apply to dry chemical assay reagents.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 3100 International System of Units and Its Application YY/T 0316 Medical Devices Risk Management for Medical Device Applications Symbols - Part 1 YY/T 0466.1 medical equipment used with medical device labels, labeling and information. General requirements

3 Requirements

3.1 Appearance In line with the provisions of the company's normal appearance requirements. 3.2 PACKING Not less than the indicated value. 3.3 reagent blank absorbance Producers meet the requirements specified. 3.4 Sensitivity Analysis Producers meet the requirements specified. 3.5 Linear Interval Serum samples were tested, o-cresol copper phthalocyanine complex method, methyl thymol blue reagent linear method in [1.00,3.75] mmol/L range, even Nitrogen arsine Ⅲ reagent linear method in [1.00,4.00] mmol/L range. a) The linear correlation coefficient ︱r︱ not less than 0.990; b) in the linear range, linearity deviation should not exceed ± 10.0%. 3.6 Precision 3.6.1 Repeatability Repeat the test concentrations (2.5 ± 0.5) mmol/L in serum control, the results of the repeatability (coefficient of variation, CV) should not exceed

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1229-2014_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1229-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1229-2014_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1229-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.