HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YY/T 1043.1-2022 English PDF

US$399.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 1043.1-2022: Dentistry - Stationary dental units and dental patient chairs - Part 1: General requirements
Status: Valid

YY/T 1043.1: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1043.1-2022English399 Add to Cart 4 days [Need to translate] Dentistry - Stationary dental units and dental patient chairs - Part 1: General requirements Valid YY/T 1043.1-2022
YY/T 1043.1-2016English519 Add to Cart 3 days [Need to translate] Dentistry--Dental units--Part 1: General requirements and test methods Obsolete YY/T 1043.1-2016
YY/T 1043-2004English559 Add to Cart 3 days [Need to translate] Dental units Obsolete YY/T 1043-2004

PDF similar to YY/T 1043.1-2022


Standard similar to YY/T 1043.1-2022

YY 1042   YY/T 0823   YY/T 0824   YY 1045   YY/T 1043.2   

Basic data

Standard ID YY/T 1043.1-2022 (YY/T1043.1-2022)
Description (Translated English) Dentistry - Stationary dental units and dental patient chairs - Part 1: General requirements
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C33
Word Count Estimation 18,116
Date of Issue 2022-10-17
Date of Implementation 2024-04-01
Older Standard (superseded by this standard) YY/T 0058-2015; YY/T 1043.1-2016
Issuing agency(ies) State Drug Administration
Summary This standard specifies the requirements and test methods for non-mobile dental units, dental patient chairs, and combinations of the two, whether or not they are powered. This standard also specifies the requirements for instructions for use, technical instructions, marking and packaging. This standard does not apply to physician chairs, portable dental equipment and dental lights.

YY/T 1043.1-2016: Dentistry--Dental units--Part 1: General requirements and test methods

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Dentistry - Dental units - Part 1. General requirements and test methods ICS 11.060.20 C33 People's Republic of China Pharmaceutical Industry Standard Replacing YY/T 1043-2004 Dental Dental Treatment Machine Part 1. General requirements and test methods (ISO 7494-1..2011, MOD) 2016-03-23 release 2017-01-01 Implementation State Food and Drug Administration issued Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 Category 4 5 request 2 6 sampling 5 7 Test 5 8 Manufacturer's instructions 6 Mark 7 10 Packaging 7 Appendix A (informative appendix) Differences and reasons for this chapter and ISO 7494-1..2011 8 Reference 9

Foreword

YY 1043 "dental dental treatment machine" is divided into two parts. - Part 1. General requirements and test methods; Part 2. Water supply and gas supply. This part is part 1 of YY 1043. YY/T 0630-2008 (ISO 7494-2..2003, IDT) is part 2 of YY 1043 and is subsequently revised. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces YY/T 1043-2004 "dental treatment machine". This section is the main change compared with YY/T 1043-2004 as follows. --- increased the definition and requirements of dental devices and high frequency surgical devices; - increased biocompatibility requirements; --- Increased requirements for the connection of the piping lines; - the need to remove the pressure release; --- updated the technical description and logo requirements; --- Removal of normative Appendix A, test sequence; --- Added information on the differences between Appendix A, this part and ISO 7494-1..2011 Chapter number differences and reasons. This section is modified using ISO 7494-1..2011 "Dental Dental Therapy Machine Part 1. General Requirements and Test Methods" (English Version). The main technical differences between this part and ISO 7494-1..2011 are as follows. --- According to the current domestic medical equipment safety requirements of the implementation of the situation, with GB 9706.1-2007 (IEC 60601-1. 1988 A1..1991 A2..1995, IDT) Replace IEC 60601-1..2005; Similarly, remove IEC 80601-2-60 "Medical electrical equipment Part 2-60. Particular requirements for basic safety and basic performance of dental equipment ", IEC 62366" Medical device availability Procedures in the application of medical devices "and 5.1.4 usability; 5.1.2, 5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.3.6 were followed by YY/T 1043-2004 "dental treatment machine" 5.1.2, 5.3.2, 5.3.10, 5.3.12.2, 5.3.13.2, 5.3.17, 7.3.2, 7.3.3 are followed by YY/T 1043-2004 Section of the treatment machine "7.3.3,7.3.4 test method; - For international standards cited in this section, if converted to our standard, this section will replace the international standard number referenced The corresponding country or industry standard number, and indicate the use of the relationship in Chapter 2; --- Added information on the differences between Appendix A, this part and ISO 7494-1..2011 Chapter number differences and reasons. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This section is proposed by the State Food and Drug Administration. This part of the National Dental Material and Equipment Standardization Technical Committee of Dental Equipment and Instruments Subcommittee (SAC/TC99 SC1). This part of the drafting unit. the State Food and Drug Administration Guangzhou Medical Device Quality Supervision and Inspection Center, Xianyang Northwest Medical Devices (Group) Co., Ltd., Foshan City Shengtian Medical Devices Co., Ltd., Ningbo Lan Ye Medical Equipment Co., Ltd., Taishan City Fu Ken scientific research industry Limited company. This part of the main drafters. Wu Yiming, Li Wei, Zhao Lijun, Li Danrong, Yang Qi, Peng Bo, Lei Kangning. This part was first published in 1965, the second revision in 1989, the third revision in.2004, this time for the fourth revision.

Introduction

This section does not contain qualitative and quantitative test methods for biological hazards, but is recommended when assessing possible biological hazards GB/T 16886.1. Dental Dental Treatment Machine Part 1. General requirements and test methods

1 Scope

This part of YY/T 1043 specifies the requirements and test methods of the dental treatment machine, whether or not it is driven by electricity. This part also specifies the manufacturer's instructions, labeling and packaging requirements.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) GB/T 9937 Oral vocabulary (all parts) [ISO 1942 (all parts), IDT] YY 0058-2015 Dental patient chair (ISO 6875..2011, MOD) Graphical symbols for dental equipment (ISO 9687..1993, IDT) YY/T 0628-2008 Access to Drainage Pipes for Dental Equipment (ISO 11144..1995, IDT) YY/T 0841-2011 Medical electrical equipment Medical electrical equipment Periodic testing and post-repair testing (IEC 62353..1997, IDT) YY/T 1285-2015 Dental Oral Health Care Personnel Dental Equipment Location Information System (ISO 4073. 2009, IDT) ISO 21530..2004 Dentistry-Materialsused Dental Materials Surface Materials Chemical Densitizers (Dentistry-Materialsused fordentalequipmentsurfaces-Determination ofresistancetochemicaldisinfectants)

3 terms and definitions

GB/T 9937, GB 9706.1-2007 and YY/T 1285-2015 and the following terms and definitions apply to this document. 3.1 Dental equipment dentalequipment Facilities, machines, instruments and accessories for dental treatment and/or related procedures. 3.2 Dental treatment machine dentalunit An interconnected dental device and apparatus constitute a functional combination of equipment for dental treatment. 3.3 Dental phone dentalhandpiece Hand-held instruments connected to dental treatment machines for oral treatment. 3.4 High frequency surgical device highfrequencysurgerydevice/HFsurgerydevice A hand-held medical electrical device for cutting or repairing biological tissue and transmitting high frequency current during a surgical procedure.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1043.1-2022_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1043.1-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1043.1-2022_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1043.1-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY/T 1043.1-2022?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 1043.1-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.