Spinal implants. Standard test method for measuring load induced subsidence of intervertebral body fusion device under static axial compression
| Valid |
YY/T 0960-2014
|
PDF similar to YY/T 0960-2014
Basic data | Standard ID | YY/T 0960-2014 (YY/T0960-2014) | | Description (Translated English) | Spinal implants. Standard test method for measuring load induced subsidence of intervertebral body fusion device under static axial compression | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C35 | | Classification of International Standard | 11.040.40 | | Word Count Estimation | 11,187 | | Date of Issue | 6/17/2014 | | Date of Implementation | 7/1/2015 | | Quoted Standard | GB/T 16825.1; YY/T 0959; ASTM F1582; ASTM F1839 | | Adopted Standard | ASTM F2267-2004, NEQ | | Regulation (derived from) | China Food and Drug Administration in 2014 Bulletin No. 30 | | Issuing agency(ies) | State Food and Drug Administration | | Summary | This Standard applies to interbody fusion. This Standard specifies the materials and methods used to promote abiotic interbody fusion in a particular axial compression of the spinal fusion segment subsidence test used. |
YY/T 0960-2014: Spinal implants. Standard test method for measuring load induced subsidence of intervertebral body fusion device under static axial compression ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Spinal implants.Standard test method for measuring load induced subsidence of intervertebral body fusion device under static axial compression
ICS 11.040.40
C35
People's Republic of China pharmaceutical industry standards
Interbody fusion spinal implant Static
Axial Compression Test Method for Subsidence
Issued on. 2014-06-17
2015-07-01 implementation
China Food and Drug Administration released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Summary of Test Method 4
5 meaning and application 4
6 Equipment 4
Selection and preparation of samples 5 7
8 static axial compression test Step 5
9 6 Report
Appendix A (informative) Basic principles 7
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard reference method using redrafted using "Standard Test Method for interbody fusion static axial compression subsidence" ASTMF2267-04
prepared by.
Technical differences between this standard and ASTMF2267-04 follows.
--- On normative references, this standard has been adjusted technical differences, in order to adapt our technical conditions, the adjusted situation
Focus is reflected in the status of Chapter 2, "Normative references", the specific adjustments are as follows.
• with GB/T 16825.1 instead ASTME4;
--- Deleted the Chapter 10, "Precision and Bias";
--- Deleted the Chapter 11 "Keyword";
--- In Appendix X1 to Appendix A, remains unchanged.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard was proposed by the China Food and Drug Administration.
This standard by the national surgical implants and orthopedic instruments Standardization Technical Committee materials and orthopedic implants Technical Committee
(SAC/TC110/SC1) centralized.
This standard was drafted. Tianjin Medical Device Quality Supervision and Inspection Center, Shanghai Medical Technology Co., Ltd. minimally invasive orthopedics.
The main drafters. Zhang Lu, Jiaoyong Zhe, Dongshuang Peng, Wang Guohui, your Haven.
Interbody fusion spinal implant Static
Axial Compression Test Method for Subsidence
1 Scope
The standard provides for the promotion of non-biological fusion cage axially a specific spinal segment fusion compression subsidence test material used
Materials and methods.
This standard is used to compare the mechanical properties of intervertebral fusion cage Interbody Fusion rather than provide performance standards designed to contrast abiotic vertebral
Fusion between the mechanical properties of the establishment of basic principles.
This standard specifies a static test method specifies the type of loading and loading methods. This test method can be used for interbody fusion
Comparative evaluation of the clutch.
This standard has been established test pieces measuring deformation and determine interbody fusion cage subsidence guidelines.
The standard unit of angle measurement in addition to the possibility of using degrees or radians, the other measurements using the International System of Units (SI).
Some require the use of additional interbody fusion implants to improve the stability, and therefore may not be in accordance with the manufacturer's recommended method to test
Such implants.
This standard does not attempt to all the security issues involved elaborate, even those safety issues associated with their use. establish
Appropriate safety and health practices and suitability before applying clear management restrictions, the user of this standard is its own responsibility.
Appendix A of this standard gives the basic principles.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Inspection and correction tension and (or) pressure testing machine force measuring system. GB/T 16825.1 of static uniaxial testing machines - Part 1
Associate (GB/T 16825.1-2008, ISO 7500-1.2004, IDT)
Interbody fusion material mechanical properties test methods YY/T 0959 spinal implant
ASTMF1582 and spinal implant-related terms (Terminologyrelatingtospinalimplants)
ASTMF1839 orthopedic instruments and tools for testing standard material rigid polyurethane foam (Specificationforrigidpolyu-
rethanefoamforuseasastandardmaterialfortestingorthopaedicdevicesandinstruments)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Coordinates/axis coordinatesystem/axes
Based ASTMF1582 defines three orthogonal axes, as shown in Figure 1. Coordinate origin located interbody fusion device geometry
Heart, X-axis along the longitudinal axis of the implant, the forward positive, Y-axis a transverse axis, Z axis indicates a vertical axis.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0960-2014_English be delivered?Answer: Upon your order, we will start to translate YY/T 0960-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0960-2014_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0960-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|