US$1019.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0910.1-2021: Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods Status: Valid YY/T 0910.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YY/T 0910.1-2021 | English | 1019 |
Add to Cart
|
7 days [Need to translate]
|
Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods
| Valid |
YY/T 0910.1-2021
|
| YY/T 0910.1-2013 | English | RFQ |
ASK
|
8 days [Need to translate]
|
Medical electrical equipment. Medical image display systems. Part 1: Evaluation methods
| Obsolete |
YY/T 0910.1-2013
|
PDF similar to YY/T 0910.1-2021
Standard similar to YY/T 0910.1-2021 YY/T 0889 YY/T 0888 YY/T 0890
Basic data | Standard ID | YY/T 0910.1-2021 (YY/T0910.1-2021) | | Description (Translated English) | Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C43 | | Word Count Estimation | 50,596 | | Issuing agency(ies) | State Drug Administration |
YY/T 0910.1-2021: Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Medical electrical equipment medical image display system. Part 1.Evaluation method)
ICS 11.040.50
C43
People's Republic of China Pharmaceutical Industry Standard
Replacing YY/T 0910.1-2013
Medical electrical equipment medical image display system
Part 1.Evaluation Methods
Part 1.Evaluationmethods
Published on 2021-09-06
2022-09-01 Implementation
Released by the State Drug Administration
directory
Preface III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and Definitions, Symbols, Abbreviations 1
3.1 Terms and Definitions 1
3.2 Symbol 3
3.3 Abbreviations 4
4 General 4
5 Prerequisite 5
6 Equipment and tools5
6.1 Luminance meter 5
6.2 Illuminance meter 5
6.3 Colorimeter 5
6.4 Test Template 6
7 Evaluation method7
7.1 Overview 7
7.2 Overview of Evaluation Method Table 7
7.3 Visual Evaluation Methods 8
7.4 Quantitative evaluation methods 14
Appendix A (Informative Appendix) Sample Test Report 19
Appendix B (Informative Appendix) Luminosity Measurement Method 33
Appendix C (Informative Appendix) Test Template Description 36
Reference 44
foreword
YY/T 0910 "Medical Image Display System for Medical Electrical Equipment" includes the following parts.
--- Part 1.Evaluation methods;
--- Part 2.Acceptance and stability tests;
This part is Part 1 of YY/T 0910.
This section is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces YY/T 0910.1-2013 "Medical Image Display System for Medical Electrical Equipment Part 1.Evaluation Method", and
Compared with YY/T 0910.1-2013, the main technical changes other than editorial changes are as follows.
--- Modified the scope (see Chapter 1, Chapter 1 of the.2013 edition);
--- Increased the alternative safety factor (see Table 1);
--- Modified the definition and interpretation of the physical parameter Δu'v' (see Table 1, Table 1 of the.2013 edition);
--- Modified the calculation formula of the maximum deviation of the brightness evaluation of multiple monitors (see 7.4.4, 7.4.4 of the.2013 edition);
--- Increased grayscale chromaticity evaluation (see 7.4.9).
Please note that some content of this document may be patented. The issuing authority of this document assumes no responsibility for identifying these patents.
This part is proposed by the State Drug Administration.
This part is approved by the National Medical Electrical Equipment Standardization Technical Committee Medical X-ray Equipment and Appliances Sub-Technical Committee (SAC/TC10/SC
1) Focal point.
This section was drafted by. Liaoning Provincial Medical Device Inspection and Testing Institute, Suzhou UL Meihua Certification Co., Ltd., Barco Vision (Beijing) Electronics
Co., Ltd. Suzhou Branch, Nanjing Jusha Display Technology Co., Ltd., EIZO Imaging Technology (Suzhou) Co., Ltd.
The main drafters of this section. Meng Zhaoyang, Zhang Bo, Zhou Xu, Zhang Xiaoyuan, Li Luwei, Wang Yue, Jin Yubo.
The previous versions of the standards replaced by this part are as follows.
---YY/T 0910.1-2013.
Introduction
This section provides methods for evaluating image display systems for diagnostic imaging used in testing medical electrical equipment and medical electrical systems.
Two types of tests should be completed at the site of use or after installation. Acceptance test after installation of new video display system or on existing video display
After the system is overhauled. Since the image display system will decay over time, the user conducts a stability test in a fixed period.
to ensure that the performance of the system remains within the expected range of use.
This section describes different evaluation methods, but does not specify which method should be used for acceptance and/or stability testing.
Rather, the purpose of this section is to provide a reference for other standards or to provide a guide for each mode, or
National authorities for evaluation methods in this standard provide a reference for defining limits and frequencies for acceptance and stability testing. See Appendix A
A sample report of such a reference is given.
In order to maintain the consistency of IEC medical electrical equipment standards, IEC 61223-2-5 "Evaluation and Routine Tests of Medical Imaging Sectors No.
Part 2-5.Image Display Device Stability Test" should be re-evaluated.
This amendment was issued to introduce color measurement.
Since IEC 62563-1.2009 has been published, IEC 61223-2-5 "Evaluation and Routine Tests in the Medical Imaging Sector Part 2-5.Figures
Like Display Device Stability Test" has been withdrawn.
Medical electrical equipment medical image display system
Part 1.Evaluation Methods
1 Scope
This section specifies evaluation methods for testing medical imaging display systems.
The scope of this section refers to experiments that can be measured by visual judgment or using basic experimental equipment. with more advanced or
Quantitative equipment tests are not within the scope of this section.
This section applies to medical image display systems that display image information in color or grayscale image display systems. This section applies to
Diagnosis (interpretation of medical images to make a clinical diagnosis) or observation (observation of medical images for medical purposes rather than providing medical images
Therefore, there are special requirements for image quality. Head-fixed image display system and image display system for determining positioning
systems and the video display systems used to operate these systems are not included in the scope of this section. Handheld video display systems may require this
Additional or modified versions of the steps described in subsections.
This section does not include requirements for defining acceptance testing and stability testing or requirements for the frequency of stability testing.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
pieces. For undated references, the latest edition (including all amendments) applies to this document.
finedterms)
ISO 11664-1.2007 Colorimetry Part 1.CIE Standard for Chromaticity Observation (Colorimetry-Part 1.CIE
photometry)
3 Terms and Definitions, Symbols, Abbreviations
3.1 Terms and Definitions
The terms and definitions defined in IEC 60788.2004 and the following terms and definitions apply to this document.
3.1.1
accuracy
The degree of agreement between test results and accepted benchmark values.
[ISO 5725-1.1994, definition 3.6]
3.1.2
Brightness
The brightness of light as perceived by the human visual system.
3.1.3
cathode ray tube cathoderaytube; CRT
Picture tube picturetube
The part of an image display system in which an image defined by an electronic signal is visible by means of an electron beam hitting a phosphor.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0910.1-2021_English be delivered?Answer: Upon your order, we will start to translate YY/T 0910.1-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0910.1-2021_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0910.1-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YY/T 0910.1-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0910.1-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|