US$1414.00 · In stock Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0723-2009: Medical electrical equipment. Digital imaging and communications in medicine (DICOM). Radiotherapy objects Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YY/T 0723-2009 | English | 1414 |
Add to Cart
|
8 days [Need to translate]
|
Medical electrical equipment. Digital imaging and communications in medicine (DICOM). Radiotherapy objects
| Valid |
YY/T 0723-2009
|
PDF similar to YY/T 0723-2009
Basic data | Standard ID | YY/T 0723-2009 (YY/T0723-2009) | | Description (Translated English) | Medical electrical equipment. Digital imaging and communications in medicine (DICOM). Radiotherapy objects | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C43 | | Classification of International Standard | 11.040.60 | | Word Count Estimation | 71,768 | | Date of Issue | 2009-06-16 | | Date of Implementation | 2010-12-01 | | Quoted Standard | GB/T 18987; ICRU 50 Report-1993 | | Adopted Standard | IEC 61852-1998, IDT | | Regulation (derived from) | Industry standard filing Notice 2009 No. 9 | | Issuing agency(ies) | State Food and Drug Administration | | Summary | This standard specifies: 1 Part 3 supplement (the principal, Appendix A, B, C and D extensions). 2 Part 4 supplement (Appendix B for an extension). 3 Part 6 supplement (for the first 6 and Appendix A of the extension). |
YY/T 0723-2009: Medical electrical equipment. Digital imaging and communications in medicine (DICOM). Radiotherapy objects ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Medical electrical equipment.Digital imaging and communications in medicine (DICOM) .Radiotherapy objects
ICS 11.040.60
C43
People's Republic of China pharmaceutical industry standards
YY/T 0723-2009/IEC 61852.1998
Medical electrical equipment - Medical Digital Imaging and Communications
(The DICOM) radiation therapy subject
(IEC 61852.1998, IDT)
Posted 2009-06-16
2010-12-01 implementation
State Food and Drug Administration issued
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
Part 3. Supplementary Information Object Definition 1 Radiation Therapy
1 Scope 1
2 Normative references 1
3. X radiation therapy 1
4 Symbols and abbreviations 2
A. U RT Image Information Object Definition 5
A. U. 1 RT Image IOD Description 5
A. U. 2 RT Image IOD Entity Relationship Model 5
A. U. 3 RT dose IOD Module Table 6
A. V RT dosage information object definitions 7
A. V. 1 RT dose IOD Description 7
A. V. 2 RT dose IOD entity-relationship model 7
A. V. 3 RT dose IOD Module Table 8
A. W RT Structure Set IOD 8
A. W. 1 RT Structure Set IOD definitions 8
A. W. 2 RT Structure Set IOD entity-relationship model 9
A. W. 3 RT Structure Set IOD modules Table 9
A. X RT Plan IOD 10
A. X. 1 RT Plan IOD Description 10
A. X. 2 RT Plan IOD entity-relationship model 10
A. X. 3 RT Plan IOD Module Table 10
A. X. 3.1 RT graded program module 11
A. X. 3.2 RT prescription module 11
A. X. 3.3 RT tolerance table module 11
A. X. 3.4 RT patient setting module 11
C. 7.3.1.1.1 Modal 11
C. 8. X radiation therapy 11
C. 8. X. 1 RT sequence module 12
C. 8. X. 2 RT image module 12
C. 8. X. 3 RT dose module 19
C. 8. X. 4 RTDVH module 21
C. 8. X. 5 structure assembly module 23
C. 8. X. 6 ROI contour module 25
C. 8. X. 7 RT dose ROI module 27
C. 8. X. 8 RTROI observation module 28
C. 8. X. 9 RT GM plans to module 30
YY/T 0723-2009/IEC 61852.1998
C. 8. X. 10 RT prescription module 31
C. 8. X. 11 RT tolerance table module 33
C. 8. X. 12 RT patient setting module 34
C. 8. X. 13 RT graded program module 35
C. 8. X. 14 RT-beam module 38
C. 8. X. 15 RT Proximity setting module 49
C. 8. X. 16 approval module 57
Part 4. Supplementary radiotherapy storage SOP Class 57
B. 5 Standard SOP Class 57
Part 6. Supplementary radiation cure data dictionary 58
YY/T 0723-2009/IEC 61852.1998
Foreword
This standard is No. 11 DICOM standard supplements. DICOM standard is published extended 3,4 and 6 parts of the
DICOM standard includes the following components.
Part 1. Introduction and overview;
Part 2. Compliance;
Part 3. Information Object Definitions;
Part 4. Service Class Specifications;
Part 5. Data Structures and Encoding;
Part 6. Data Dictionary;
Part 7. Message Exchange;
Part 8. Network Communication Support for Message Exchange;
Part 9. Point Communication Support for Message Exchange;
Part 10. Media storage and file format;
Part 11. Media storage applications framework;
Part 12. Media Format and Physical Media;
Part 13. print management point to point communication support.
These parts are related but independent documents. Their development level and approval status may differ. Another part may be added
Into this multi-part standard in the past. PS3.1 should be used as the current standard reference base.
This standard is identical with IEC 61852.1998.
For ease of use, this standard made the following editorial changes.
--- Deleting IEC 61676.2002 Foreword;
--- In Chapter 2, "Normative references", the referenced IEC and ISO standards, who have converted to equivalent national standards (including meter
The amount of test regulations), the references to the national standards.
This standard was proposed by the State Food and Drug Administration.
This standard by the national radiotherapy, nuclear medicine and radiation dosimetry equipment Standardization Technical Committee (SAC/TC10/SC3) centralized.
This standard by MASEP Medical Technology Development (Shenzhen) Co., Ltd., Beijing Medical Device Testing is responsible for drafting.
The main drafters of this standard. Xu Tao, Meng Zhiping.
YY/T 0723-2009/IEC 61852.1998
Introduction
The DICOM standard defines a number of the supplementary information object applies to the field of radiation oncology. The purpose of these is to support the
This radiation therapy department between internal radiation therapy and radiation therapy device transport sector outside the relevant data. But it is not intended to support the preaching
Lose data management, this function may be raised in future revisions of DICOM.
Since radiotherapy departments still lack a consistent process models, especially in an international context, which in the current draft has not yet introduced stream
Process management tasks. Therefore, radiation therapy information object contains a large number of conditional optional data elements. These objects are designed to phase in nature
Off radiation therapy data "container", in which the data object is added in the process.
YY/T 0723-2009/IEC 61852.1998
Medical electrical equipment - Medical Digital Imaging and Communications
(The DICOM) radiation therapy subject
Part 3 of DICOM supplements and/or amendments.
Part 3. Supplementary Information Object Definition Radiation Therapy
1 Scope
The report provides information on the following objects.
Radiotherapy DICOM image information of the object. This object specifies the semantic content of the RT image, usually abbreviated as RT Image IOD.
It also includes the appropriate storage service class, so the IOD can be used for network storage and media exchange. RT Image IOD range is defined by
Radiation therapy image acquired cone beam imaging, such as traditional analog machines and portal imaging device. It can also be applied to the same geometry calculations Figure
Like, such as digital X-ray reconstruction (DRRs).
1) DICOM radiation dose information object. This object specifies the semantic content of RT dose, usually abbreviated as RT dose
IOD. It also includes the appropriate storage service class, so the IOD can be used for network storage and media exchange. RT dose IOD
The range is radiotherapy treatment planning system to calculate the dose distribution, the performance of two or three dimensional dose grid, rename or
Unnamed point dose group, isodose and dose volume histograms (DVHs).
2) DICOM radiotherapy structure information object set. This object specifies the semantic content of the RT structure sets, usually abbreviated as RT knot
Configuration set IOD. It also includes the appropriate storage service class, so the IOD can be used for network storage and media exchange. RT Structure
IOD range set refers to the radiation therapy equipment such as CT scanners, virtual simulation workstation or treatment planning system defined
Related structures set patient.
3) DICOM radiotherapy treatment planning information object. This object specifies the semantic content RT (treatment) program, usually abbreviated as RT
Plan IOD. It also includes the appropriate storage service class, so the IOD can be used for network storage and media exchange. RT Plan
IOD range refers to a predetermined external irradiation and/or geometric and dosimetric data brachytherapy procedure.
This standard includes DICOM supplement the existing part of the many; so readers understand enough to deal with DICOM standards.
1. Part 3 supplement (extension of the body, Appendix A, B, C and D).
2. Part 4 replenishment (extended to appendix B).
3. Part 6 supplement (extension of the Section 6 and Appendix A).
Added to Chapter 2
2 Normative references
GB/T 18987 Radiotherapy equipment Coordinates, movements and scales (GB/T 18987-2003, IEC 61217.1996)
No. ICRU50 Report.1993 "photon beam therapy prescription, recording and reporting" the International Commission on Radiation Units and Measurement
After the following is added to section 3.8
3. X radiation therapy
This part of this standard uses the following terms defined in IEC 61217.
a) the fixed reference frame;
b) coordinate frame;
YY/T 0723-2009/IEC 61852.1998
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0723-2009_English be delivered?Answer: Upon your order, we will start to translate YY/T 0723-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0723-2009_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0723-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|