YY/T 0661-2017: Standard specification for semi - Crystalline poly(lactide) polymer and copolymer resin for surgical implants
Status: Valid

YY/T 0661: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0661-2017English319 Add to Cart 4 days [Need to translate] Standard specification for semi - Crystalline poly(lactide) polymer and copolymer resin for surgical implants Valid YY/T 0661-2017
YY/T 0661-2008English279 Add to Cart 3 days [Need to translate] Standard specification for virgin poly(L-lactic acid) resin for surgical implants Obsolete YY/T 0661-2008

PDF similar to YY/T 0661-2017


Standard similar to YY/T 0661-2017

YY/T 0647   YY/T 0752   YY/T 0695   YY/T 0663.2   YY/T 0651.2   

Basic data

Standard ID YY/T 0661-2017 (YY/T0661-2017)
Description (Translated English) Standard specification for semi - Crystalline poly(lactide) polymer and copolymer resin for surgical implants
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Classification of International Standard 11.040.40
Word Count Estimation 16,157
Date of Issue 2017-09-25
Date of Implementation 2018-10-01
Older Standard (superseded by this standard) YY/T 0661-2008
Regulation (derived from) China Food & Drug Administration Announcement 2017 No. 118
Issuing agency(ies) State Food and Drug Administration

YY/T 0661-2017: Standard specification for semi - Crystalline poly(lactide) polymer and copolymer resin for surgical implants


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard specification for semi-Crystalline poly (lactide) polymer and copolymer resin for surgical implants ICS 11.040.40 C35 People's Republic of China pharmaceutical industry standards Replaced YY/T 0661-2008 Surgical implant semi-crystalline polylactide Polymer and copolymer resins Standardspecification forsemi-Crystalinepoly (lactide) polymerand 2017-09-25 Published 2018-10-01 implementation State Food and Drug Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 materials and manufacturing 2 5 chemical composition 2 6 Physical Properties 6 7 Performance Requirements 6 8 Size, quality and tolerance 7 9 sample preparation 7 10 Supporting Documents 7 11 Package and Package Marking 8 Appendix A (informative) named 9 Appendix B (informative) Principle 10 Appendix C (Normative) Biocompatibility 12 Reference 13

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces YY/T 0661-2008 "surgical implant poly (L-lactic acid) resin standard", and YY/T 0661-2008 In addition, editorial changes in addition to the main technical changes are as follows. --- Increased the scope of the standard (see Chapter 1); --- Added and modified certain physical and chemical performance requirements and the corresponding test methods (see Chapter 5, Chapter 6, Chapter 7); --- Increased size, quality and tolerance (see Chapter 8); --- Increasing the sample preparation (see Chapter 9); --- Increased proof (see Chapter 10); --- Increased naming (see Appendix A) and biocompatibility (see Appendix C). This standard uses redrafted Law reference ASTMF1925-09 "surgical implants semi-crystalline polylactide polymers and copolymers Resin "preparation. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the State Food and Drug Administration. This standard by the National Surgical Implants and Orthopedic Instruments Standardization Technical Committee (SAC/TC110) centralized. This standard was drafted unit. Tianjin Medical Device Quality Supervision and Inspection Center, Le Pu (Beijing) Medical Devices Co., Ltd., Jiangsu 100 Easy Medical Technology Co., Ltd. The main drafters of this standard. Li Yuan, Zhu Jin, Zheng Jun translation, Fang Yuan, Ding Jianzhong, Zou Rongrong. This standard replaces YY/T 0661-2008. YY/T 0661-2008 the previous version of the release. --- YY/T 0661-2008. Surgical implant semi-crystalline polylactide Polymer and copolymer resins

1 Scope

1.1 This standard applies to surgical implants with a native semi-crystalline poly (L-lactide) or poly (D-lactide) homopolymer resin, also applies to L-lactide and other bio-absorbable monomer copolymerized semi-crystalline resin. These monomers include but are not limited to glycolide, D-lactide and DL-lactide. Poly (L-lactide) or poly (D-lactide) homopolymers and copolymers in this standard contain lactide fragments long enough, So after annealing will cause its potential crystallization. This polymer typically has a mole fraction of L-lactide equal to or greater than 50%. This standard It is especially suitable for the production of isotactic lactide-based block copolymers or composites of D-lactide and L-lactide with a total molar difference of more than 1.5% Synthesized polymer or copolymer. This standard includes fully soluble in methylene chloride or chloroform at 30 ° C native semi-crystalline Type polylactic acid based resin. Note. Refer to Appendix A for the nomenclature of polymers. 1.2 This standard does not apply to glycolide molar fraction of greater than or equal to 70% (mass fraction of 65.3%) of lactide - glycolide copolymerization Does not apply to lactide glycolide copolymers that have a glycolide segment of sufficient size to provide a potential glycolide-based crystal, The material needs to be completely dissolved at room temperature using a fluorinated solvent (see ASTM F2313); it also does not apply to amorphous polymers or to total Copolymers of D-lactide and L-lactide complexes with a difference in molar fraction of more than 1.5% (see YY/T 0510). 1.3 This standard, the semi-crystalline resin is annealed by differential scanning calorimetry to determine the glass transition temperature above the heat of crystallization to define of. While fragments of other copolymerization segments may also crystallize upon annealing (eg, glycolide), other than the crystalline structure formed from lactide The specific characterization of the crystal structure is outside the scope of this standard. 1.4 This standard specifies the material properties of primary semi-crystalline polylactide-based resins for surgical implants that are not suitable for use in the manufacture of these materials Packaged sterilized finished implant. Any of the materials, processing techniques used to manufacture parts or equipment (such as molding, extrusion, machining, Assembly, sterilization, etc.) can change its performance. Therefore, the resin processed products, the performance standards involved in this should be used to ensure its safety and Effective test method for evaluation.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1033.2 Determination of density of plastics, non-foamed plastics - Part 2. Density gradient column method GB/T 1632.5 Plastics - Determination of the viscosity of dilute polymer solutions using a capillary viscometer - Part 5. Thermoplastic homopolymerization and copolymerization Polyester (TP) GB/T 6040 General rules of infrared spectroscopy GB/T 6425 thermal analysis terms GB 11998 plastic glass transition temperature measurement method (thermal mechanical analysis) GB/T 19466.3 Plastics - Differential Scanning Calorimetry (DSC) - Part 3. Determination of melting and crystallization temperature and enthalpy GB/T 21864 Polystyrene average molecular weight and molecular weight distribution of the standard test methods High-performance size exclusion chromatography YY/T 0510 surgical implants with amorphous polylactide resin and lactide - glycolide copolymer resin

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0661-2017_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0661-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0661-2017_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0661-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY/T 0661-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0661-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.