US$239.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0625-2016: Dentistry--Wires for use in orthodontics Status: Valid YY/T 0625: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YY/T 0625-2016 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
Dentistry--Wires for use in orthodontics
| Valid |
YY/T 0625-2016
|
YY 0625-2008 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Dentistry. Orthodontic Products: Wires
| Obsolete |
YY 0625-2008
|
PDF similar to YY/T 0625-2016
Basic data Standard ID | YY/T 0625-2016 (YY/T0625-2016) | Description (Translated English) | Dentistry--Wires for use in orthodontics | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | Classification of Chinese Standard | C33 | Classification of International Standard | 11.060.10 | Word Count Estimation | 12,167 | Date of Issue | 2016-03-23 | Date of Implementation | 2017-01-01 | Older Standard (superseded by this standard) | YY 0625-2008 | Regulation (derived from) | Notice of the General Administration of Food and Drug Administration (No. 74 of 2016) | Issuing agency(ies) | State Food and Drug Administration |
YY/T 0625-2016: Dentistry--Wires for use in orthodontics---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Dentistry - Wires for use in orthodontics
ICS 11.060.10
C33
People's Republic of China Pharmaceutical Industry Standard
Replacing YY 0625-2008
Dental Orthodontics
(ISO 15841..2006, MOD)
2016-03-23 release
2017-01-01 Implementation
State Food and Drug Administration issued
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces YY 0625-2008 "orthodontic products. orthodontic silk", compared with YY 0625-2008, the main technical changes
as follows.
--- 3.2 in the definition of bending stiffness, the "dimension of MPa". Change to "unit is N/mm".
--- To the size of 5.2, the "cross-sectional size should be marked in the size of ± 0.01mm" requirements, with "cross-sectional size should be accurate to
0.01mm ".
--- 5.3 Austenite transition in the end of the temperature, the "austenite transition temperature range should be marked to ± 1 ℃" requirements,
Changed to "austenite transition end temperature should be accurate to 1 ℃".
--- cancel the 5.4 mechanical properties, all on the "measurement accuracy of 1%" requirements.
--- In Section 5.4.2, the "permanent flexural deformation rate" is changed to "permanent flexural deformation".
- In the 6.4.1 tensile test, the "elastic modulus is determined by measuring the slope of the stress-strain curve straight line segment" with "6.4.2.3.6
The modulus of elasticity is determined by measuring the slope of the force-displacement curve straight line segment.
This standard is the main difference between ISO 15841..2006 and ISO 15841..2006 for the revision of the ISO 15841..2006 Dental Orthodontic Wire standard.
--- modify Figure 1.
--- increase the type of orthodontic bending stiffness curve of the diagram, "Figure 4 bending stiffness curve", and the back of the drawing number extension.
--- Modify Figure 4 Bend test curve.
--- will be 7.3, "g) for nickel, beryllium products, should contain a warning symbol (including the exclamation point of the triangle) and warning text. 'the
The product contains nickel. 'And/or' this product contains beryllium. '. "Changed to." g) There should be a warning to the harmful elements contained in the product
The appropriate place should be symbolic way). "
And the normative reference in this standard international documents are consistent with the relationship between China's documents are as follows.
GB/T 228.1-2010 Metallic materials - Tensile testing - Part 1. Room temperature test method (ISO 6892-1..2009,
MOD).
GB/T 9937 (all parts) Oral vocabulary [ISO 1942 (all parts), IDT].
This document is as follows. (1) The documents of this paper are as follows.
GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1. Evaluation and testing in risk management
(ISO 10993-1..2009, IDT).
- YY/T 0268-2008 Dental Oral Medical Device Biological Evaluation Unit 1. Evaluation and Test (ISO /FDIS
7405-2008, NEQ).
Please note that some of the contents of this document may involve patents. The issuer of this document shall not be responsible for the identification of such patents.
This standard is proposed by the State Food and Drug Administration.
This standard is nationalized by the National Standardization Technical Committee for Dental Materials and Equipment (SAC/TC99).
The drafting of this standard. the State Food and Drug Administration Peking University Medical Device Quality Supervision and Inspection Center, the research and development of new materials shares
Co., Ltd., Minnesota Mining Manufacturing (Shanghai) International Trade Co., Ltd., Beijing St. Matt Technology Co., Ltd.
The main drafters of this standard. Zheng Gang, Bai Wei, Miao Weidong, Han Jie, Huang Bingmin, Sun Zhihui, Yuan Shenpo.
This standard replaced the previous version of the standard release.
--- YY 0625-2008.
Introduction
It is difficult to effectively compare the development of orthodontic silk.
Dental Orthodontics
1 Scope
This standard specifies the requirements and test methods for the production of orthodontic fibers for fixed and removable orthodontic appliances. This standard applies to preforming
Of the orthodontic arch wire, this standard does not apply to springs and other preforms.
This standard specifies the physical and mechanical properties of the distorted silk, as well as the corresponding requirements for the corresponding test methods, packaging and identification information.
This standard does not contain qualitative and quantitative requirements for possible biological hazards, but it is recommended that in assessing possible biological hazards,
See ISO 7405 and ISO 10993-1.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
ISO 1942 (all parts) oral vocabulary (Dentistry-Vocabulary)
ISO 6892 Metallic materials at room temperature tensile test method (Metalicmaterials-Tensiletestatatambienttemper-
ature
3 terms and definitions
ISO 1942 (all parts) and the following terms and definitions apply to this document.
3.1
Austenite - finishtemperature
Taf
The temperature at which the alloy is converted from the low temperature martensite to the high temperature austenite phase.
3.2
Bending stiffness
Sb
Increase the load value required for the unit deflection in N/mm (for example, in the case where the deflection of the bending test is proportional to the load,
Bending test).
3.3
Descriptor descriptor
According to the accepted orthodontic convention, the identification code for the nominal cross-sectional size of the orthodontic silk, expressed as a thousandth of an inch without unit name
(For example, 16, 18, 17 x 25, 21 x 21).
3.4
Diagonal diagonal
Square wire maximum cross - sectional size.
see picture 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0625-2016_English be delivered?Answer: Upon your order, we will start to translate YY/T 0625-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0625-2016_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0625-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YY/T 0625-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0625-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|