US$219.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0616.6-2021: (The 6th part of the use method of medical gloves: Anti-war drug performance test method) Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YY/T 0616.6-2021 | English | 219 |
Add to Cart
|
3 days [Need to translate]
|
(The 6th part of the use method of medical gloves: Anti-war drug performance test method)
| Valid |
YY/T 0616.6-2021
|
PDF similar to YY/T 0616.6-2021
Basic data Standard ID | YY/T 0616.6-2021 (YY/T0616.6-2021) | Description (Translated English) | (The 6th part of the use method of medical gloves: Anti-war drug performance test method) | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | Classification of Chinese Standard | C48 | Word Count Estimation | 10,191 | Issuing agency(ies) | State Drug Administration |
YY/T 0616.6-2021: (The 6th part of the use method of medical gloves: Anti-war drug performance test method) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(The 6th part of the use method of medical gloves. Anti-war drug performance test method)
ICS 11.140.01
C48
People's Republic of China Pharmaceutical Industry Standard
Disposable medical gloves
Part 6.Evaluation of anti-chemotherapy drug permeability
experiment method
Published on 2021-09-06
2022-09-01 Implementation
Released by the State Drug Administration
foreword
YY/T 0616 "Disposable Medical Gloves", consists of the following parts.
--- Part 1.Biological evaluation requirements and tests;
--- Part 2.Requirements and tests for determining shelf life;
--- Part 3.Method for determining the actual time expiration date with finished gloves in storage;
--- Part 4.Test method for puncture resistance;
--- Part 5.Test method for resistance to chemical penetration and continuous exposure;
--- Part 6.Test method for evaluating the permeability of anti-chemotherapy drugs;
--- Part 7.Immunological determination of antigenic protein content.
This part is part 6 of YY/T 0616.
This section is drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that some content of this document may be patented. The issuing authority of this document assumes no responsibility for identifying these patents.
This part is proposed by the State Drug Administration.
This part is under the jurisdiction of Shandong Medical Device Product Quality Inspection Center.
This section is drafted by. Shandong Medical Device Product Quality Inspection Center, Lanfan Medical Co., Ltd., Shijiazhuang Hongrui Group Co., Ltd.
Ltd.
The main drafters of this section. Zhang Limei, Xu Zhizhou, Guo Lijuan, Liu Wenjing, Liu Guixi.
Introduction
At work, medical staff may come into contact with some chemicals (such as various disinfectants, chemical sterilants,
chemicals, etc.), causing various degrees of damage to the human body, such as acute trauma such as skin irritation or burns, as well as some chronic variable diseases
sick. In order to avoid such hazards, products with corresponding protective properties (such as disposable medical gloves) are required, and the protection category (such as chemical
Medical use) or protection level (such as level 1), so as to better guide medical staff to choose suitable products to wear for effective protection.
YY/T 0616.5 establishes a general test method for chemical penetration resistance of disposable medical glove materials. This section will give specific
Application, that is, a test method for evaluating the anti-chemotherapy drug penetration performance of disposable medical glove materials.
Disposable medical gloves
Part 6.Evaluation of anti-chemotherapy drug permeability
experiment method
1 Scope
This part of YY/T 0616 specifies the evaluation of anti-chemotherapy drug penetration performance of disposable medical gloves under continuous contact conditions.
Test conditions, test procedures and report of results.
This section applies to single-use medical gloves intended for protection against chemotherapeutic drugs.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2941 Rubber Physical Test Methods General Procedures for Specimen Preparation and Conditioning
YY/T 0616.5-2019 Disposable medical gloves-Part 5.Resistance to chemical penetration and continuous exposure test method
3 Terms and Definitions
The terms and definitions defined in YY/T 0616.5-2019 and the following terms and definitions apply to this document.
3.1
The time from the start of the test to the penetration rate just reaching 0.01μg/cm2/min, the unit is min.
Note. Rewrite YY/T 0616.5-2019, definition 3.1.
4 Method overview
4.1 The anti-chemotherapy drug penetration performance of disposable medical gloves is evaluated by measuring the breakthrough detection time of the drug passing through the gloves.
Add the tested chemotherapeutic drug solution to the challenge chamber of the penetration test pool, and add a suitable collection medium to the collection chamber (that is, the collection medium does not affect the test drug).
permeability to substances such as water or other liquids). If the test drug can penetrate the test glove, after the drug has passed through the test material, it will continue to pass through, and its concentration
The degree increases with time. The collection medium is sampled and quantitatively analyzed at specified time intervals to determine the chemotherapeutic agent in the collection medium
content of the substance. According to the test method specified in YY/T 0616.5-2019, the breakthrough detection time and permeability are calculated from the drug content in the collection medium.
penetration rate.
4.2 When evaluating the anti-chemotherapy drug penetration performance of disposable medical gloves, refer to Table A.1 in Appendix A to select 7 kinds of test drugs.
and refer to Table A.2 to select at least 2 more representative clinical drugs.
5 Test device
Closed test test device and test method given in YY/T 0616.5-2019, for single-use medical gloves for anti-chemotherapy drugs
Substance penetration test.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0616.6-2021_English be delivered?Answer: Upon your order, we will start to translate YY/T 0616.6-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0616.6-2021_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0616.6-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|