US$534.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0590.3-2011: Medical electrical equipment. Characteristics of digital X-ray imaging devices. Part 1-3: Determination of the detective quantum efficiency. Detectors used in dynamic imaging Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YY/T 0590.3-2011 | English | 534 |
Add to Cart
|
4 days [Need to translate]
|
Medical electrical equipment. Characteristics of digital X-ray imaging devices. Part 1-3: Determination of the detective quantum efficiency. Detectors used in dynamic imaging
| Valid |
YY/T 0590.3-2011
|
PDF similar to YY/T 0590.3-2011
Basic data | Standard ID | YY/T 0590.3-2011 (YY/T0590.3-2011) | | Description (Translated English) | Medical electrical equipment. Characteristics of digital X-ray imaging devices. Part 1-3: Determination of the detective quantum efficiency. Detectors used in dynamic imaging | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C43 | | Classification of International Standard | 11.040.50 | | Word Count Estimation | 27,250 | | Date of Issue | 2011-12-31 | | Date of Implementation | 2013-06-01 | | Quoted Standard | YY/T 0063; YY/T 0481-2004; ISO 12232-1998; IEC TR 60788-2004 | | Adopted Standard | IEC 62220-1-3-2008, IDT | | Regulation (derived from) | State Food and Drug Administration Notice No. 106 of 2011 | | Issuing agency(ies) | State Food and Drug Administration | | Summary | This standard specifies the requirements on manufacturers of medical work under the conditions of use to air kerma and spatial frequency as a function of digital X-ray imaging apparatus method for measuring the quantum detection efficiency. The intended users of this part of the manufacturer and well-equipped testing laboratory. This section is used to limit the dynamic image digital X-ray imaging apparatus, such as, but not limited to, directly or indirectly based flat panel detector system. Inappropriate to YY/T 0590 used in this part of the X-ray image intensifier-based digital systems. YY/T 0590 This section does not apply to: use in mammography or dental photography, digital X-ray imaging apparatus, computed tomography equipment, scans the patient's X-ray imaging system. |
YY/T 0590.3-2011: Medical electrical equipment. Characteristics of digital X-ray imaging devices. Part 1-3: Determination of the detective quantum efficiency. Detectors used in dynamic imaging
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Medical electrical equipment.Characteristics of digital X-ray imaging devices.Part 1-3. Determination of the detective quantum efficiency.Detectors used in dynamic imaging
ICS 11.040.50
C43
People's Republic of China pharmaceutical industry standards
Medical electrical equipment - Characteristics of digital X-ray imaging apparatus
Part 1-3. Determination of the detective quantum efficiency
Dynamic imaging with detector
Part 1-3. Determinationofthedetectivequantumefficiency-
(IEC 62220-1-3.2008, IDT)
Issued on. 2011-12-31
2013-06-01 implementation
State Food and Drug Administration issued
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
Requirement 3 4
3 4.1 Operating Conditions
4.2 X-ray equipment 4
4.3 quality of the radiation 4
4.4 Experimental Devices 4
4.5 geometry 4
Irradiation conditions 6 4.6
4.6.1 General Conditions 6
Air ratio of kinetic energy release 4.6.2 Measurement 7
4.6.3 lag effect 7
4.6.4 To obtain the conversion function of irradiation 8
4.6.5 Irradiation for measuring noise power spectrum and the lagged effects of 8
4.6.6 radiation beam in irradiated test devices 9
4.6.7 Overview of all necessary irradiated 9
5 9 unprocessed data correction
6 Determination of the quantum detection efficiency of 10
6.1 DQE (u, v) and the definition of formula 10
6.2 10 parameters for evaluation
By the image measuring different parameters 11 6.3
11 6.3.1 Data linearization
Noise power spectrum 6.3.2 lag effect after correction (NPS) 11
6.3.3 Determination of the modulation transfer function (MTF) of 13
Format 7 Declaration of Conformity 14
8 Accuracy 14
Determination of Annex A (informative) Hysteresis 15
Annex B (informative) Calculation of input noise power spectrum 17
References 18
Index 20
Foreword
YY/T 0590 "Medical electrical equipment - Characteristics of digital X-ray imaging apparatus" is divided into the following sections.
--- Part 1. Determination of the detective quantum efficiency;
--- Part 1-2. Determination of the detective quantum efficiency of breast X-ray photography detectors;
--- Part 1-3. Determination of dynamic imaging using quantum detection efficiency of the detector.
This section YY/T Part of 1-30590.
This section drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this section may involve patents, the present document issuing authority does not bear the responsibility to identify these patents.
This section uses the translation method identical with IEC 62220-1-3.2008 "Medical electrical equipment - Characteristics of digital X-ray imaging apparatus section
Part 1-3. Determination of the detective quantum efficiency with dynamic imaging detectors. "
This part made the following editorial changes.
--- Remove the IEC foreword;
--- Some of the statements apply to international standards to apply to our standard formulation.
This part is proposed by the State Food and Drug Administration.
This part of the National Technical Committee of Standardization for medical appliances medical X-ray equipment and utensils Standardization Technical Committee (SAC/TC10 /
SC1) centralized.
This section is drafted. Liaoning Medical Device Control, Space Star Space Technology Applications Co., Hang Wei universal health care system
Limited, Siemens Shanghai Medical Equipment Co., Ltd.
The main drafters of this section. Sun Zhiyong, Zou Yuan, Feng-Chao, Guo Qiang, Shou water.
Introduction
Digital X-ray imaging device is being increasingly widely used in medical diagnostics and gradually replace the traditional screen-film X-ray systems and analog
Image intensifier television system. Therefore, it is necessary to define the description of the digital X-ray imaging apparatus imaging performance parameters and the use of specific measurement procedures standard
Normalized.
In the scientific community is the growing consensus detective quantum efficiency (DQE) is the most appropriate description of the parameters X-ray imaging apparatus imaging performance.
DQE describes an image forming apparatus to maintain the ability to output from the radiation field of digital image data signal to noise ratio. In the X-ray imaging, radiation field
Noise and air kerma levels are closely related, so DQE values can also be used as a digital X-ray imaging device description given
Dose efficiency.
Note 1. Although DQE has been widely used to describe the performance of the image forming apparatus, but the relationship of the physical parameters of the behavior of a human observer has not yet determined
Completely understood [1], [3] 1).
Note 2. YY/T 0457.5-2003 specific description is a method, this approach is mainly used to determine the spatial frequencies close to zero in the X-ray image enhancement
The detective quantum efficiency. It focuses on optoelectronic components research X-ray image intensifier, rather than standard main imaging properties of the present. therefore,
It is a measure of the amount of an optical (brightness), instead of digitized data. In addition, YY/T 0457.5-2003 specifies the radiation source assembly causes
Use, and this standard specifies the use of X-ray tube. Range YY/T 0457.5-2003 is defined in the X-ray image intensifier, and not with
The scope of the standard conflict.
1) The numbers in square brackets reference number.
DQE is already widely used by the manufacturer to characterize the performance of its digital X-ray imaging apparatus, DQE specification also by management (for example,
FDA) as a recognized procedures. However, whether the measurement conditions or the measurement procedure is currently no standard specification, resulting in different
Data sources are not comparable.
Therefore, the enactment of this section in order to standardize the digital X-ray imaging apparatus detective quantum efficiency measurement procedures and compliance statement format.
In the DQE calculation method recommended in this section, the system response is to assume that all the energy is equal attenuation measured [5].
This section would benefit manufacturers, users, vendors, and management. It is a series of three related standards in the third file.
Part 1. suitable for X-ray photography, not including breast X-ray photography and fluoroscopy.
Part 1-2. suitable for breast X-ray photography.
This part is the Part 1-3. suitable for dynamic imaging detector.
Described above can be seen as part of a digital X-ray imaging apparatus related parameters YY/T 0590 the first part of series of standards.
Medical electrical equipment - Characteristics of digital X-ray imaging apparatus
Part 1-3. Determination of the detective quantum efficiency
Dynamic imaging with detector
1 Scope
YY/T 0590 This section specifies the use under medical conditions specified by the manufacturer working to release the kinetic energy of air ratio and spatial frequency
Determination of the detective quantum efficiency of digital X-ray imaging apparatus function. Expected users of this section is the manufacturer and well-equipped test
laboratory.
This section limits for dynamic imaging of digital X-ray imaging apparatus, such as, but not limited to, directly or indirectly, based on flat panel detector
system.
This should not be part of YY/T 0590 is applied based on the X-ray image intensifier digital system.
Note 1. The reason why not is based on the phenomenon of low frequency drop and vignetting and geometric distortion phenomenon appears to consider in these devices, these phenomena may be serious
Limit measuring method described in this section applicability.
YY/T 0590 This section does not apply to.
--- Use of digital X-ray imaging apparatus mammography or dental photography;
--- Computer tomography equipment; and
--- Patient scan imaging X-ray systems;
Note 2. Does not include the above-described means, because they contain a lot different than for dynamic imaging very important parameters (for example, radiation quality, geometry, time
Dependence, etc.). Some of these parameters in other parts (YY/T 0590.1 and YY/T 0590.2) has been specified.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
YY/T 0063 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal (YY/T 0063-2007, IEC 60336.
2005, IDT)
YY/T 0481-20042) medical diagnostic X-ray equipment with radiation characteristic measurement conditions (IEC 61267.1994, IDT)
2) Although the IEC 61267 2nd edition (2005) has been released, but in order to make the IEC 62220 series of standards conformance, to the first edition (IEC 61267.
1994) is also a special reservation throughout this standard.
ISO 12232.1998 Determination of the electronic still photographic images from the camera's ISO speed (Photography-Electronicstil-
picturecameras-DeterminationofISO speed)
IEC TR60788.2004 Medical electrical equipment defined in the glossary (Medicalelectricalequipment-Glossary
ofdefinedterms)
3 Terms and Definitions
IEC 60788 define the following terms and definitions apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0590.3-2011_English be delivered?Answer: Upon your order, we will start to translate YY/T 0590.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0590.3-2011_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0590.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|