YY/T 0273-2022: (dentistry dental amalgam blender)
Status: Valid

YY/T 0273: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0273-2022English329 Add to Cart 4 days [Need to translate] (dentistry dental amalgam blender) Valid YY/T 0273-2022
YY/T 0273-2009English359 Add to Cart 3 days [Need to translate] Dental amalgamators Obsolete YY/T 0273-2009
YY/T 0273-1995English399 Add to Cart 3 days [Need to translate] Dental amalgamators Obsolete YY/T 0273-1995

PDF similar to YY/T 0273-2022


Standard similar to YY/T 0273-2022

YY 0270.1   YY 0304   YY/T 0268   YY 0271.2   YY 0272   

Basic data

Standard ID YY/T 0273-2022 (YY/T0273-2022)
Description (Translated English) (dentistry dental amalgam blender)
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C33
Word Count Estimation 17,133
Issuing agency(ies) State Drug Administration

YY/T 0273-2009: Dental amalgamators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Dental amalgamators ICS 11.060.20 C33 People's Republic of China pharmaceutical industry standards Replacing YY/T 0273-1995 Dental amalgam blending device (ISO 7488.1991, MOD) Posted 2009-11-15 2010-12-01 implementation State Food and Drug Administration issued

Foreword

This revised standard adopts the International Standard ISO 7488.1991 "Dental amalgam blending device." This standard and ISO 7488.1991 The main differences are as follows. The requirements for electrical safety standard GB 4793.1-2007 "measurement, control and laboratory safety requirements for electrical equipment Part 1 Score. General requirements "instead of ISO 7488.1991 is referenced in IEC 335-1. 1976 (IDT, GB 4706.1" Household and similar electrical appliances Safety - Part 1. General requirements "). Instead of the standard YY/T 0273-1995 "dental amalgam blending device." Compared with the standard YY/T 0273-1995 The main changes are as follows. a) The full implementation of electrical safety standard GB 4793.1-2007, YY/T 0273-1995 only in the implementation of GB 9706.1-1995 "Protective grounding impedance, dielectric strength and continuous leakage current" 3; b) The standard delete environmental testing requirements specified by the companies in their product standards; c) The standard delete noise, appearance, inspection rules and other requirements prescribed by enterprises in their product standards. This standard by the National Dental Materials and Devices Equipment Standardization Technical Committee dental equipment and instruments at the Technical Committee. This standard was drafted. State Food and Drug Administration Guangzhou Medical Device Quality Supervision and Inspection Center. The main drafters of this standard. Wu Ming lean, Liwei Song, publicity. This standard by the National Materials and Devices Equipment Standardization Technical Committee dental equipment and instruments at the Technical Committee is responsible for interpretation of the oral cavity. This standard was first released in November 1995.

Introduction

Blending electric amalgam is mainly used to refer to silver alloy powder and mercury are mixed through vibration and provide sufficient mechanical energy to amalgamation, too Dental amalgam to the machine, but will also be used mixed with other dental materials. Some amalgam blending is equipped with a special plastic capsule and repeated use, used to hold silver alloy powder and mercury, although in use or tested Cheng, the plastic capsule itself should be seen as part of the blending, but does not require it relates to this standard in the future, if necessary, may This special capsule separately standards. Some blending amalgam alloy powder or appliance installed partakers mercury or both may dispensing function. This machine in addition to the dispensing part, should also be the root According to the present standards for testing. Dental amalgam blending device

1 Scope

This standard specifies the electrical blending device for mixing silver alloy powder and mercury, amalgam and get through vibration requirements and signs, as well as How to determine the requirements and test methods amalgam blending complies with the above requirements. This standard provides a comparison of these methods work the blending operation and performance consistency, to ensure amalgam blending repeatability.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 4793.1-2007 measurement, control and laboratory use safety requirements for electrical equipment - Part 1. General requirements (IEC 61010-1. 2001, IDT)

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 When the state of all the silver alloy powder and amalgamation into a single homogeneous substance when. Note. small cracks or surface looks dry, etc., are not considered not adjusted Hao. 3.2 Parallel to the direction of movement of the largest interior of the capsule size or in normal operation, the capsules do periodic motion in the plane of motion, flat Line in the direction of the capsule inside the capsule main maximum size. 3.3 Range of motion in the working length of the capsule capsule midpoint millimeters (mm). Category 4 Amalgam blending the following categories. Class 1. Fixed frequency type; Class 2. variable frequency type.

5 Requirements

5.1 Electrical Safety Shall comply with the requirements of GB 4793.1-2007. 5.2 Safety of machinery 5.2.1 capsule blending should be equipped with a protective cover. 5.2.2 The operator often come into contact with moving parts should be smooth, there should be no sharp edges.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0273-2022_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0273-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0273-2022_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0273-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY/T 0273-2022?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0273-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.