HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YY 0803.3-2016 English PDF

US$519.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY 0803.3-2016: Dentistry. Root-canal instruments. Part 3: Condensers
Status: Obsolete

YY 0803.3: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY 0803.3-2016English519 Add to Cart 3 days [Need to translate] Dentistry. Root-canal instruments. Part 3: Condensers Obsolete YY 0803.3-2016
YY/T 0803.3-2016English289 Add to Cart 3 days [Need to translate] Dentistry-Root-canal instruments --Part 3: Codensers Valid YY/T 0803.3-2016

PDF similar to YY 0803.3-2016


Standard similar to YY 0803.3-2016

YY 1042   YY/T 0823   YY/T 0824   YY/T 0803.1   YY/T 0803.2   YY/T 0803.5   

Basic data

Standard ID YY 0803.3-2016 (YY0803.3-2016)
Description (Translated English) Dentistry. Root-canal instruments. Part 3: Condensers
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C33
Classification of International Standard 11.060.20
Word Count Estimation 13,162
Date of Issue 2016-01-26
Date of Implementation 2018-01-01
Quoted Standard GB/T 9937.3-2008; YY 0803.1-2010; YY/T 0873.1; YY/T 0873.2; YY/T 0873.3; YY/T 0873.4; YY/T 0873.5; YY/T 0873.6; YY/T 0873.7
Adopted Standard ISO 3630-3-1994, MOD
Regulation (derived from) China Food and Drug Administration Bulletin 2016 No.25
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the requirements and test methods for the vertical and lateral pressurizers used to compact the root canal filling material. In addition to the standard specifications, also includes the tapered size. This type of taper size is determined by the taper that varies with the size of the instrument.

YY 0803.3-2016: Dentistry. Root-canal instruments. Part 3: Condensers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Dentistry.Root-canal instruments.Part 3. Condensers ICS 11.060.20 C33 People's Republic of China Pharmaceutical Industry Standard Dentistry root canal instruments - Part 3. Pressers (ISO 3630-3..1994 Dentalroot-canalinstruments- Part 3. Condensers, pluggersandspreaders, MOD) 2016-01-26 release 2018-01-01 implementation State Food and Drug Administration issued

Foreword

The technical content of this section is mandatory. The "dental root canal instrument" consists of the following four parts. - Part 1. General requirements and test methods (YY 0803.1); - Part 2. Amplifier (YY/T 0803.2); Part 3. Pressurizer (YY 0803.3); - Part 4. Auxiliary equipment (YY/T 0803.4); - Part 5. Forming and cleaning (YY/T 0803.5). This section is part 3. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section is modified using the ISO 3630-3..1994 "Dental Surgery Root Canal Device Part 3. Press, Vertical Press and Side Press Device ". The main differences between this part and ISO 3630-3..1994 are as follows. --- on the normative reference documents, the standard has done a technical differences in the adjustment to meet the technical conditions of China, the adjustment of the situation Is reflected in Chapter 2, "normative reference documents", the specific adjustments are as follows. • YY 0803.1-2010 "Dentistry Root Canal Instruments Part 1. General Requirements and Test Methods" (ISO 3630-1. 2008, IDT) Replacing ISO 3630-1..1992 "Dental Rotary Instruments Part 1. Root canal files, amplifiers, barbed plucking Needle, rough file, paste conveyor, probe and cotton twist "; • Replacement of ISO 6360-1. 1985 with YY/T 0873 (all parts) "Digital Coding System for Dental Rotary Instruments" Rotating instrument digital coding system - Part 1. General characteristics; - Split ISO 3630-3..1994 Figure 3 into Figures 3 and 4; --- Taper identification is expressed as a percentage. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This section is composed of the National Committee for the Standardization of Dental Materials and Instruments, the Subcommittee on Dental Equipment and Instruments (SAC/TC99 / SC1). This section is composed of the National Committee for the Standardization of Dental Materials and Instruments, the Subcommittee on Dental Equipment and Instruments (SAC/TC99 / SC1). This part of the drafting unit. the State Food and Drug Administration Guangzhou Medical Device Quality Supervision and Inspection Center, Shenzhen speed technology development Limited company. This part of the main drafters. Lu Wenjuan, Wang Zhong, Li Danrong, Yuan Qin.

Introduction

YY 0803 covers important features of hand-held root canal instruments for root canal preparation. In addition to special equipment, YY 0803.1 contains the general characteristics, requirements and test methods for all types of root canal instruments. It is noteworthy that, YY/T 0873 "dental rotary instrument digital coding system" provides a set of digital coding system, provides a 15 digits for distinguishing between various types of dental rotating instruments. Dentistry root canal instruments - Part 3. Pressers

1 Scope

This part of YY 0803 specifies the requirements and test methods for vertical compressors and side compressors used to compact the root canal filling material. In addition to the standard specifications, it also includes tapered specifications. This type of tapered specification is determined by the taper that varies with the size of the instrument.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 9937.3-2008 Oral vocabulary - Part 3. Oral instruments (ISO 1942-3. 1989, IDT) YY 0803.1-2010 Dentistry Root canal equipment - Part 1. General requirements and test methods (ISO 3630-1..2008, IDT) YY/T 0873 (all parts) Dental Rotary Instruments Digital Coding System [ISO 6360 (all parts), IDT]

3 terms and definitions

GB/T 9937.3 Definitions of terms and definitions and the following terms and definitions apply to this document. 3.1 Root canal filling press root-canalfilingcondenser The working part is cylindrical or tapered, rounded hand-held instruments. For vertical and/or lateral compaction of root canal filling material. plus The presses are usually divided into vertical compressors and side compressors. Note. Handheld devices include finger-on devices and hand-held instruments. 3.2 Root canal filling vertical pressureer root-canalfilingplugger The working part is cylindrical or tapered, the cross section is round, the face is the plane hand-held instrument. Mainly used for vertical compaction of root canal filling material. 3.3 Root canal filling lateral pressureer root-canalfilingspreader The working part is a tapered, rounded, rounded hand-held instrument. Mainly used for lateral compaction of root canal filling material.

4 requirements

4.1 Materials The operating part of the instrument should be made of corrosion-resistant material. The type of material and the method of handling are specified by the manufacturer. The handle or rod should be of plastic material or other corrosion resistant material, the material selected by the manufacturer. 4.2 Dimensions of standard vertical presses and standard side compressors General rules Dimensions in millimeters.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY 0803.3-2016_English be delivered?

Answer: Upon your order, we will start to translate YY 0803.3-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY 0803.3-2016_English with my colleagues?

Answer: Yes. The purchased PDF of YY 0803.3-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY 0803.3-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0803.3-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.