YY 0460-2009: Ultrasonics dental descaler equipment
Status: Obsolete

YY 0460: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY 0460-2009English279 Add to Cart 3 days [Need to translate] Ultrasonics dental descaler equipment Obsolete YY 0460-2009
YY 0460-2003English879 Add to Cart 6 days [Need to translate] Ultrasonics dental descaler equipment Obsolete YY 0460-2003

PDF similar to YY 0460-2009


Standard similar to YY 0460-2009

YY/T 0593   YY 0307   YY 0592   YY 0789   YY 0599   YY/T 0458   

Basic data

Standard ID YY 0460-2009 (YY0460-2009)
Description (Translated English) Ultrasonics dental descaler equipment
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C41
Classification of International Standard 11.060.20
Word Count Estimation 7,782
Date of Issue 2009-11-15
Date of Implementation 2010-12-01
Older Standard (superseded by this standard) YY 0460-2003
Quoted Standard GB 9706.1-2007; GB/T 14710; YY/T 0751-2009
Regulation (derived from) Industry standard filing Notice 2010 No. 2 (No. 122 overall)
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the ultrasonic scaler equipment terminology and definitions, requirements, test methods and inspection rules. This standard applies to 18kHz ~ 60kHz frequency range, from the ultrasonic transducer to generate a continuous or quasi- continuous wave ultrasonic energy ultrasonic teeth cleaning device (hereinafter referred to as the instrument).

YY 0460-2009: Ultrasonics dental descaler equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Ultrasonics dental descaler equipment ICS 11.060.20 C41 People's Republic of China pharmaceutical industry standards Replacing YY 0460-2003 Ultrasonic scaler equipment Posted 2009-11-15 2010-12-01 implementation State Food and Drug Administration issued

Foreword

4.5,4.9 and 4.10 of this standard is recommended requirements, the rest is mandatory. This standard replaces YY 0460-2003 "ultrasonic scaler equipment." This standard YY 0460-2003 compared to major changes are as follows. a) delete the original standard Chapter 4, "symbol"; b) In Chapter 4, "Requirements", increasing the main vibrating tip manufacturer's published offset tip vibration frequency and half biasing force three indicators The measured data with a predetermined deviation, an increase of instrument functional requirements; c) simplify the exposition of the test method, the main performance test method of the present standard of a direct reference YY/T 0751-2009 (IEC 61205) "ultrasonic scaler device output characteristic measurement and disclosure"; d) simplifying the Chapter 7, "Inspection Rules" in the factory contents inspection; e) delete the original standard Chapter 8 "signs and instructions for use"; f) Remove the original standard test used to describe the principle of the method and the informative Appendix A, Appendix B and Appendix D; g) fully implement common safety standard GB 9706.1-2007, delete the original standard normative appendix C. This standard by the standardization of medical ultrasound equipment for medical appliances National Standardization Technical Committee Technical Committee (SAC/TC10/SC2) Centralized. This standard was drafted. State Food and Drug Administration of Hubei Medical Device Quality Supervision and Inspection Center. The main drafters of this standard. Wang Zhijian, busy Ashmore. This standard was first released in June 2003. Ultrasonic scaler equipment

1 Scope

This standard specifies the terms and definitions ultrasonic teeth cleaning equipment, requirements, test methods and inspection rules. This standard applies in the 18kHz ~ 60kHz frequency range, by an ultrasonic transducer generates a continuous or quasi-continuous wave Doppler energy ultra Acoustic teeth cleaning device (hereinafter referred to as the instrument).

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) GB/T 14710 medical electrical environmental requirements and test methods YY/T 0751-2009 Ultrasonic Scaling Device Measurement and publish output characteristics (IEC 612051. 1988, IDT)

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Tip must be in contact with the slides, the applied force, so that the tip of the main vibrating 0.15N ± 0.02N offset falling under the conditions of contact force 50% lower. 3.2 In the role of the head from the tip of no more than 1mm from the point of maximum amplitude in the direction of the peak to peak displacement of the application head. 3.3 Effect tip of the fundamental frequency of vibration.

4 Requirements

4.1 main vibrating tip offset Manufacturers should publish the main vibrating tip offset value in the random file. Deviation published with the measured values should be within a range of ± 50% of or compliance with the manufacturer's specifications. 4.2 tip vibration frequency Manufacturers should publish numerical tip vibration frequency in a random file. Deviation published with the measured values should be within a range of ± 10% of or compliance with the manufacturer's specifications. 4.3 Semi-biasing force Manufacturers shall publish half biasing force values in a random file. Deviation published with the measured values should be within a range of ± 50% of or compliance with the manufacturer's specifications. 4.4 The main vibrating tip offset adjustment Main vibrating tip offset should be adjusted, the adjustment range can be reduced to 50% of maximum.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY 0460-2009_English be delivered?

Answer: Upon your order, we will start to translate YY 0460-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY 0460-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YY 0460-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY 0460-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0460-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.