US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 902-2013: Methods for chemical analysis of high purity rhenium and ammonium perrhenate. Determination of beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, ind Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 902-2013 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of high purity rhenium and ammonium perrhenate. Determination of beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, ind
| Valid |
YS/T 902-2013
|
PDF similar to YS/T 902-2013
Basic data | Standard ID | YS/T 902-2013 (YS/T902-2013) | | Description (Translated English) | Methods for chemical analysis of high purity rhenium and ammonium perrhenate. Determination of beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, ind | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H63 | | Classification of International Standard | 77.120.99 | | Word Count Estimation | 6,685 | | Regulation (derived from) | Ministry of Industry and Information Technology Bulletin No. 52, 2013; industry standard for filing Notice No. 1 of 2014 (No. 169 overall) | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies the purity acid by Lai Lai and beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, indium, tin, antimony, barium, tungsten, pl |
YS/T 902-2013: Methods for chemical analysis of high purity rhenium and ammonium perrhenate. Determination of beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, ind
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of high purity rhenium and ammonium perrhenate. Determination of beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, ind
ICS 77.120.99
H63
People's Republic of China Nonferrous Metals Industry Standard
High purity ammonium rhenium and rhenium chemical analysis
Beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium,
Chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium,
Determination of indium, tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth content
Inductively Coupled Plasma Mass Spectrometry
Determinationofberylium, sodium, magnesium, aluminum, potassium, calcium, titanium,
chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium,
indium, tin, antimony, barium, tungsten, platinum, thalium, leadandbismuthcontent-
Issued on. 2014-03-01 2013-10-17 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized.
This standard was drafted. Beijing Nonferrous Metal Research Institute, Zhuzhou Cemented Carbide Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy, jinduicheng
Molybdenum Co., Ltd.
The main drafters of this standard. Li Jidong, Zhang Ying, Wang Changhua, Sun Zeming, Liu Ying, Chenqiu Lian Feng advanced, Wang Guoliang, Tong Jian, Zang Muwen.
High purity ammonium rhenium and rhenium chemical analysis
Beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium,
Chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium,
Determination of indium, tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth content
Inductively Coupled Plasma Mass Spectrometry
1 Scope
This standard specifies the high purity ammonium rhenium and rhenium, beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, indium,
Tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth content determination.
This standard applies to high-purity ammonium rhenium and rhenium, beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, indium,
Tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth content was measured. Measurement range. 0.0001% to 0.0050%.
2 Method summary
The sample is dissolved in nitric acid to rhodium internal standard calibration, inductively coupled plasma mass spectrometry directly determined by the working curve method to calculate each
Mass concentration of the element, expressed in mass fraction measurement results.
3 Reagents
Unless otherwise indicated, reagents were pure class distinctions used in this standard, the use of water as a water.
3.1 Hydrofluoric acid (ρ = 1.16g/mL)
3.2 nitric acid (11).
3.3 nitric acid (19).
3.4 beryllium, sodium, magnesium, aluminum, potassium, calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, rhodium, cadmium, indium, barium, platinum, thallium, lead (nitrate medium); tin, antimony , bismuth (hydrochloric acid
Medium); titanium, molybdenum, tungsten (hydrofluoric acid medium) standard stock solution (National Reference/national standard), the concentration of 1000μg/mL.
3.5 mixed standard solution A. Pipette 10mL each element standard stock solution (except rhodium element) (3.4), respectively, in 1000mL plastic container
Flask, additional 2mL of hydrofluoric acid (3.1), 20mL of nitric acid (3.2), dilute to the mark and mix. This solution 1mL containing beryllium, sodium, magnesium,
Aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium, indium, tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth each 10μg.
3.6 mixed standard solution B. Pipette 10mL to 100mL mixed standard solution A plastic flask supplemented with 2mL nitric acid (3.2),
Dilute with water to volume, and mix. This solution 1mL containing beryllium, sodium, magnesium, aluminum, potassium, calcium, titanium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, molybdenum, cadmium,
Indium, tin, antimony, barium, tungsten, platinum, thallium, lead, bismuth each 1μg, the time is now equipped with.
3.7 rhodium internal standard solution. Pipette 1mL rhodium-element standard stock solution (3.4) in 1000mL plastic flask, nitric acid supplemented with 20mL
(3.2), dilute to the mark and mix. This solution 1mL rhodium-containing 1μg.
4 Instrument
4.1 Inductively coupled plasma mass spectrometry. mass resolution better than 10% of the peak height (0.8 ± 0.1) u; with hydrofluoric acid resistant sample introduction system;
Equipped to eliminate interfering ions such as 38Ar1H, 40Ar and 40Ar16O and other components.
4.2 Determination of isotopes of the elements shown in Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 902-2013_English be delivered?Answer: Upon your order, we will start to translate YS/T 902-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 902-2013_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 902-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|