US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 715.2-2009: Methods for chemical analysis of selenium dioxide. Part 2: Determination of arsenic, cadmium, iron, mercury, lead contents. Inductively coupled plasma-atomic emission spectrometry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 715.2-2009 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of selenium dioxide. Part 2: Determination of arsenic, cadmium, iron, mercury, lead contents. Inductively coupled plasma-atomic emission spectrometry
| Valid |
YS/T 715.2-2009
|
PDF similar to YS/T 715.2-2009
Basic data | Standard ID | YS/T 715.2-2009 (YS/T715.2-2009) | | Description (Translated English) | Methods for chemical analysis of selenium dioxide. Part 2: Determination of arsenic, cadmium, iron, mercury, lead contents. Inductively coupled plasma-atomic emission spectrometry | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H12 | | Classification of International Standard | 77.120.10 | | Word Count Estimation | 7,758 | | Date of Issue | 2009-12-04 | | Date of Implementation | 2010-06-01 | | Regulation (derived from) | MIIT [2009] No. 66 | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies: arsenic, cadmium, iron, mercury, lead volume Determination of selenium dioxide. This standard applies to selenium dioxide (96. 00% to 99. 99%) of arsenic, cadmium, iron, mercury, lead measured. |
YS/T 715.2-2009: Methods for chemical analysis of selenium dioxide. Part 2: Determination of arsenic, cadmium, iron, mercury, lead contents. Inductively coupled plasma-atomic emission spectrometry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of selenium dioxide.Part 2. Determination of arsenic, cadmium, iron, mercury, lead contents.Inductively coupled plasma-atomic emission spectrometry
ICS 77.120.10
H12
People's Republic of China Nonferrous Metals Industry Standard
Methods for chemical analysis of selenium dioxide
Part 2. arsenic, cadmium, iron, mercury, lead and determining the amount of
Inductively coupled plasma atomic emission spectrometry
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 715 "selenium dioxide chemical analysis method" is divided into five parts.
--- Part 1. Determination of the amount of selenium dioxide, sodium thiosulfate titration;
--- Part 2. arsenic, cadmium, iron, mercury, lead content - Inductively coupled plasma atomic emission spectrometry;
--- Part 3. Determination of chlorine content of silver chloride turbidimetric method;
--- Part 4. residue on ignition - Gravimetric method;
--- Part 5. water-insoluble content - Gravimetric method.
This section YS/T Part 2 715.
This section in Appendix A, Appendix B is an informative annex.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This section is responsible for drafting unit. Tongling Nonferrous Metals Group Holdings Limited.
Participated in the drafting of this section. Jiangxi Copper Group Co., Ltd., Guangzhou Nonferrous Metal Research Institute.
The main drafters of this section. Liqin Mei, Jiang Lihong, and from Shao, Chen Huiwen, Luo Suhua, Liutian Ping, Wang Xueping, Dai Fengying.
Methods for chemical analysis of selenium dioxide
Part 2. arsenic, cadmium, iron, mercury, lead and determining the amount of
Inductively coupled plasma atomic emission spectrometry
1 Scope
YS/T in this part 715 provides for arsenic, cadmium, iron, mercury, lead content determination of selenium dioxide.
This section applies to selenium dioxide (96.00% - 99.99%) measurement of arsenic, cadmium, iron, mercury, lead, and measuring range in Table 1.
Table 1 Measuring range
As Cd Fe Hg Pb element
Content /% 0.0010 0.0030 0.0010 0.0050 0.0005 0.0030 0.0010 0.0050 0.0005 0.0050
2 Method summary
Sample dilute nitric acid dissolved in dilute nitric acid medium, using inductively coupled plasma emission spectrometer to measure selenium dioxide, arsenic, cadmium,
Iron, mercury, lead element content.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloric acid (ρ1.19g/mL), pure class distinctions.
3.2 nitrate (ρ1.42g/mL), pure class distinctions.
3.3 nitric acid (1 + 1).
3.4 nitric acid (1 + 9).
3.5 mixed acid. hydrochloric acid + nitric acid (3 + 1).
3.6 arsenic standard stock solution. (100μg/mL) Weigh 0.3300g trioxide (mass fraction of not less than 99.9%) in 100mL
Beaker, was added 5mL sodium hydroxide solution (200g/L), stirring to dissolve, add 20mL water, 2 drops of phenolphthalein ethanol solution (1g/L)
Nitric acid (3.3) and to the red just disappeared, and then excess 2mL, moved with nitric acid (3.4) 250mL volumetric flask and dilute to the mark,
Mix well.
3.7 cadmium standard stock solution. (100μg/mL) were weighed 0.1000g metal cadmium (mass fraction of not less than 99.99%) in a group
100mL beaker were added 30mL of nitric acid (3.3), cover sheet pan, heated until completely dissolved, boiled to remove nitrogen oxides, respectively, shift
Into a 1000mL volumetric flask, dilute with water to volume, and mix.
3.8 lead standard stock solution. (100μg/mL) were weighed 0.1000g metallic lead (mass fraction of not less than 99.99%) in a group
100mL beaker were added 30mL of nitric acid (3.3), cover sheet pan, heated until completely dissolved, boiled to remove nitrogen oxides, respectively, shift
Into a 1000mL volumetric flask, dilute with water to volume, and mix.
3.9 iron standard stock solution. (100μg/mL) Weigh 0.1000g metallic iron (mass fraction of not less than 99.99%) in a 100mL
Beaker, 10mL of nitric acid (3.3), cover sheet pan, on low heat until completely dissolved, remove the cooling transferred 1000mL volumetric flask,
Dilute with water to volume, and mix.
3.10 Mercury standard stock solution. (100μg/mL) Weigh 0.1354g mercury dichloride (mass fraction of not less than 99%) in the 100mL beaker
Added 10mL of nitric acid (3.3), was dissolved and transferred to 1000mL volumetric flask and dilute to volume, and mix.
3.11 Cd, Hg, Pb standard solution. Pipette 15.00mL are cadmium, lead, mercury standard storage solution was placed in 100mL volumetric flask.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 715.2-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 715.2-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 715.2-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 715.2-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|