US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 587.10-2016: Calcined coke for carbon anode--Part 10: Determination of bulk density Status: Valid YS/T 587.10: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 587.10-2016 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Calcined coke for carbon anode--Part 10: Determination of bulk density
| Valid |
YS/T 587.10-2016
|
| YS/T 587.10-2006 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
Calcined coke for prebaked blocks. Testing methods. Part 10: Determination of bulk density (tapped)
| Obsolete |
YS/T 587.10-2006
|
PDF similar to YS/T 587.10-2016
Basic data | Standard ID | YS/T 587.10-2016 (YS/T587.10-2016) | | Description (Translated English) | Calcined coke for carbon anode--Part 10: Determination of bulk density | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | Q52 | | Classification of International Standard | 71.100.10 | | Word Count Estimation | 9,935 | | Date of Issue | 2016-04-05 | | Date of Implementation | 2016-09-01 | | Older Standard (superseded by this standard) | YS/T 587.10-2006 | | Regulation (derived from) | The Ministry of Industry and Notice No. 2016 in 2016; the industry standard for the record 2016 No. 6 | | Issuing agency(ies) | Ministry of Industry and Information Technology |
YS/T 587.10-2016: Calcined coke for carbon anode--Part 10: Determination of bulk density---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calcined coke for carbon anode - Part 10. Determination of bulk density
ICS 71.100.10
Q52
People's Republic of China Nonferrous Metals Industry Standard
Replace YS/T 587.10-2006
Determination of Petroleum Coke in Carbon Anode by Calcined
Part 10. Determination of tap density
Part 10. Determination ofbulkdensity
2016-04-05 release
2016-09-01 implementation
Issued by the Ministry of Industry and Information Technology of the People's Republic of China
Foreword
YS/T 587 "Carbon anode with calcined calcined petroleum coke after the test method" a total of 14 parts.
- Part 1. Determination of ash;
- Part 2. Determination of moisture;
- Part 3. determination of volatiles;
- Part 4. Determination of sulfur;
- Part 5. Determination of trace elements;
- Part 6. Determination of powder resistivity;
- Part 7. Determination of CO2 reactivity - Mass loss method;
- Part 8. Determination of air reactivity - Mass loss method;
- Part 9. Determination of true density;
- Part 10. Determination of tap density;
- Part 11. Determination of particle stability;
- Part 12. Determination of particle size distribution;
- Part 13. Determination of Lc values;
Part 14. Determination of the Hadgrove index.
This section is part 10 of YS/T 587.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section is a revision of YS/T 587.10-2006, compared with YS/T 587.10-2006, the main technical changes are as follows.
- the vibration method (method 2) is added on the basis of the tapping method (method 1);
--- In the case of editorial changes to the tap method, refer to ISO 10236..1995 to modify the repeatability limit from ≤0.02g/cm3
Is ≤ 0.01g/cm3, and the reproducibility limit is changed from ≤0.05g/cm3 to ≤0.02g/cm3.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This part of the main drafting unit. China Aluminum Zhengzhou Nonferrous Metal Research Institute Co., Ltd., nonferrous metals Technology and Economic Research Institute.
This part participates in the drafting unit. Jinan Aohai Carbon Co., Ltd., Ningxia Ningping Carbon Co., Ltd., Zhengzhou Haoyu Carbon Material
Limited company, Shandong Chenyang new carbon materials Co., Ltd., cable-Development Co., Ltd., Shandong Yanzhou Carbon Products Co., Ltd., Feicheng
Prosperity Special Graphite Co., Ltd.
This part of the main drafters. Zhang Shuzhao, Guo Yongheng, Huang Hua, Li Bo, Zhao Chunfang, Lu Hongsen, Yu Lei, Liu Zhen, Cao Peifeng, Xi Zhaoyang, Yu Yiru,
Gao Shuei, Chen Xiaojun, Zhao Qingbo.
This part of the previous version of the standard to replace the release of the situation.
YS/T 587.10-2006.
Determination of Petroleum Coke in Carbon Anode by Calcined
Part 10. Determination of tap density
1 Scope
This part of YS/T 587 specifies the method for determining the true density of petroleum coke after calcination.
This part is suitable for the determination of the real density of petroleum coke after calcination. The method 1 is suitable for the determination of particle size in the range of 0.25mm ~
(TBD); Method 2 is suitable for the use of vibration particle size range of 0.212mm ~ 7.00mm
(VBD) of the 2 kg calcined petroleum coke sample, and the maximum particle size of the particles in the sample was measured within the above particle size range
Degree and minimum particle size ratio should be less than 2 2, should be less than 2.
2 Method 1. Tap method
2.1 Principle of the method
The tap density depends on the size, shape and porosity of the particles. Samples of similar particle size and shape can be obtained by comparing the tap density
And true density to estimate the porosity. Porosity is an important parameter that affects the quality and performance of the prebaked anode.
The volume of the material is determined to be determined after a certain amount of material is determined, and the tap density is calculated from the known mass divided by the measured volume.
2.2 Instruments and devices
2.2.1 Tap method The measuring device of the tap density is shown in Figure 1, which includes.
--- Measuring tube. the quality of 190g ± 5g, scale 0mL ~ 250mL, the accuracy of 1mL.
--- cylinder holder. the quality of 450g ± 5g guide piston.
--- Pincer device. every minute to enhance and drop the guide piston 250 ± 15 times, the height of 3mm ± 0.1mm, with the number of beat
Recorder.
2.2.2 Test sieve. Screen diameter 8.0mm, 4.0mm, 2.0mm, 1.0mm, 0.5mm, 0.25mm.
2.2.3 Oven. temperature can be controlled at 110 ℃ ± 5 ℃.
2.2.4 Feeder. Feed to the measuring tube in a controlled manner.
2.2.5 balance. range of not less than 1000g, accuracy is better than 0.1g.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 587.10-2016_English be delivered?Answer: Upon your order, we will start to translate YS/T 587.10-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 587.10-2016_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 587.10-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 587.10-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 587.10-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|