US$199.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 575.10-2007: Methods for chemical analysis of bauxite. Part10: Determination of manganese oxide content. Flame atomic absorption spectrophotometric method Status: Valid YS/T 575.10: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 575.10-2007 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of bauxite. Part10: Determination of manganese oxide content. Flame atomic absorption spectrophotometric method
| Valid |
YS/T 575.10-2007
|
| YS/T 575.10-2006 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of bauxite. Determination of manganese oxide content. Flame atomic absorption spectrophotometric method
| Obsolete |
YS/T 575.10-2006
|
PDF similar to YS/T 575.10-2007
Basic data | Standard ID | YS/T 575.10-2007 (YS/T575.10-2007) | | Description (Translated English) | Methods for chemical analysis of bauxite. Part10: Determination of manganese oxide content. Flame atomic absorption spectrophotometric method | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | Q52;D42 | | Classification of International Standard | 71.100.10 | | Word Count Estimation | 6,620 | | Date of Issue | 2007-11-14 | | Date of Implementation | 2008-05-01 | | Older Standard (superseded by this standard) | YS/T 575.10-2006 | | Regulation (derived from) | NDRC Notice No. 77 of 2007 | | Issuing agency(ies) | National Development and Reform Commission | | Summary | This standard specifies the content of bauxite Determination of manganese oxide method. This standard applies to bauxite Determination of manganese oxide, measuring range: �� 0. 20%. |
YS/T 575.10-2007: Methods for chemical analysis of bauxite. Part10: Determination of manganese oxide content. Flame atomic absorption spectrophotometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of bauxite.Part 10. Determination of manganese oxide content.Flame atomic absorption spectrophotometric method
ICS 71.100.10
Q52
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 575.10-2006
Methods for chemical analysis of bauxite -
Determination of manganese oxide content. Part 10
Flame Atomic Absorption Spectrometry
Posted 2007-11-14
2008-05-01 implementation
National Development and Reform Commission issued
Foreword
YS/T 575-2007 "chemical analysis of bauxite -" Is the YS/T 575-2006 (formerly GB/T 3257-1999) amendments
A total of 24 parts.
--- Part 1. aluminum oxide content - EDTA titration
--- Part 2. silica content - Gravimetric - molybdenum blue spectrophotometry
--- Part 3. Determination of silica content molybdenum blue photometric
--- Part 4. iron oxide content - Potassium dichromate titration
--- Part 5. Determination of iron oxide content phenanthroline spectrophotometry
--- Part 6. Determination of titanium dioxide content di Zhao DAM spectrophotometry
--- Part 7. calcium oxide content - Flame Atomic Absorption Spectrometry
--- Part 8. magnesium oxide content - Flame Atomic Absorption Spectrometry
--- Part 9. potassium hydroxide, sodium oxide content - Flame Atomic Absorption Spectrometry
--- Part 10. Determination of manganese oxide content by flame atomic absorption spectrometry
--- Part 11. chromium oxide content - Flame Atomic Absorption Spectrometry
--- Part 12. Determination of vanadium pentoxide content of benzoyl phenylhydroxylamine photometric method
--- Part 13. Determination of zinc content by flame atomic absorption spectrometry
--- Part 14. Determination of total rare earth oxide Tribromoarsenazo spectrophotometry
--- Part 15. Determination of gallium oxide content of rhodamine B extraction spectrophotometry
--- Part 16. Determination of phosphorus pentoxide molybdenum blue photometric
--- Part 17. Determination of sulfur content - Combustion - iodometric method
--- Part 18. Determination of total carbon content - Combustion - non-aqueous titration
--- Part 19. Determination of burning weight reduction method
--- Part 20. pre-dried sample preparation
--- Part 21. Determination of organic carbon titration
--- Part 22. Analysis of samples moisture intrudes content - Gravimetric method
--- Part 23. Determination of the chemical composition of the X-ray fluorescence spectrometry
--- Part 24. Determination of carbon and sulfur content infrared absorption method
This section section 10.
The partial replacement of YS/T 575.10-2006 (formerly GB/T 3257.10-1999).
This section is amended to YS/T 575.10-2006, compared with YS/T 575.10-2006, the main changes are as follows.
--- The drying temperature of the sample unified 110 ℃ ± 5 ℃;
--- Increased precision.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This part of the Aluminum Corporation of China Zhengzhou Research Institute is responsible for drafting.
This section drafted by the Aluminum Corporation of China Henan Branch.
The main drafters of this section. Chunchao Li Liang Qian, all jade, Zhou Jianmin, sea victory, Governor tube.
The non-ferrous metal part by the National Standardization Technical Committee responsible for the interpretation.
This part of the standard replaces the previous editions are.
--- YS/T 575.10-2006 (formerly GB/T 3257.10-1999).
Methods for chemical analysis of bauxite -
Determination of manganese oxide content. Part 10
Flame Atomic Absorption Spectrometry
1 Scope
This section specifies the determination method of bauxite manganese oxide content.
This section applies to the determination of bauxite manganese oxide content measurement range. ≤0.20%.
2 principle of the method
Melt Decomposition of samples with sodium hydroxide, extracted into hydrochloric acid solution with water, in the presence of strontium, atomic absorption spectrophotometer wavelength
279.5nm at the air - acetylene flame measured manganese oxide.
3 Reagents
3.1 sodium hydroxide, pure class distinctions.
3.2 hydrochloric acid (6mol/L).
3.3 nitric acid (1 + 1).
3.4 strontium chloride (SrCl2 · 6H2O) solution. 150g/L.
3.5 substrate solution. Weigh 6g sodium hydroxide (3.1) in the 250mL beaker, dissolved in water, add 80mL of hydrochloric acid (3.2), cooled and transferred to
250mL volumetric flask, dilute to the mark, shake.
3.6 manganese oxide standard stock solution. Weigh 0.3098g of manganese metal (accurate to 0.0001g, manganese metal is not less than 99.5%) in 250mL
Beaker, add 5mL nitric acid (3.3) and dissolved and transferred to 1000mL volumetric flask, add 20mL of hydrochloric acid (3.2), dilute to the mark, shake
uniform. This solution 1mL containing 400μg manganese oxide.
3.7 manganese oxide standard solution. dispensing 10.00mL manganese oxide standard stock solution (3.6) in 1000mL volumetric flask, dilute with water to
Mark and shake. 1mL solution containing 4μg manganese oxide.
4 Instrument
4.1 atomic absorption spectrophotometer, with manganese hollow cathode lamp.
Under optimum working conditions, to achieve the following indicators atomic absorption spectrophotometer can be used.
Low sensitivity. the highest concentration of arithmetic concentration of the standard absorbance reading of not less than 0.5 (including post-scale expansion), the ruler extended
Absorbance readings, its stability must comply with the following provisions.
Linear curve. the arithmetic difference between the absorbance readings of the two highest concentration of the standard concentration of the standard solution is not less than the lowest concentration standard
Zero solution concentration of the solution and 0.7 times the light absorbing reading difference.
Minimum stability. absorbance readings the highest concentration of the standard solution with zero concentration of multiple measurements obtained with respect to the highest concentration of the standard solution
Liquid absorbance readings mean coefficient of variation were less than 1.5% and 0.6%.
4.2 silver crucible. 30mL, with a crucible cover.
5 Sample
The sample was ground with a mortar through 74μm sieve, the sample is placed in a good research at 110 ℃ ± 5 ℃ oven drying 2h, placed in a desiccator, cooled
But to room temperature before use.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 575.10-2007_English be delivered?Answer: Upon your order, we will start to translate YS/T 575.10-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 575.10-2007_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 575.10-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 575.10-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 575.10-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|