US$169.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 568.3-2008: Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of silicon content. Spectrophotometric method with the reduced silicomolybdic comples Status: Valid YS/T 568.3: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 568.3-2008 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of silicon content. Spectrophotometric method with the reduced silicomolybdic comples
| Valid |
YS/T 568.3-2008
|
| YS/T 568.3-2006 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
(Zirconium, hafnium silicon oxide measured amount (molybdenum blue photometric method))
| Obsolete |
YS/T 568.3-2006
|
PDF similar to YS/T 568.3-2008
Basic data | Standard ID | YS/T 568.3-2008 (YS/T568.3-2008) | | Description (Translated English) | Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of silicon content. Spectrophotometric method with the reduced silicomolybdic comples | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H63 | | Classification of International Standard | 77.120.99 | | Word Count Estimation | 6,651 | | Date of Issue | 2008-03-12 | | Date of Implementation | 2008-09-01 | | Older Standard (superseded by this standard) | YS/T 568.3-2006 | | Regulation (derived from) | NDRC Notice No. 25 of 2008 | | Issuing agency(ies) | National Development and Reform Commission | | Summary | This standard specifies the hafnium oxide, zirconium oxide and silicon content determination. This standard applies to zirconium oxide and hafnium oxide of silicon content. Measuring range: 0. 005% ~ 0. 7%. |
YS/T 568.3-2008: Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of silicon content. Spectrophotometric method with the reduced silicomolybdic comples ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods for zirconium oxide and hafnium oxide.Determination of silicon content.Spectrophotometric method with the reduced silicomolybdic comples
ICS 77.120.99
H63
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 568.3-2006
Zirconium oxide, hafnium oxide chemical analysis
Determination of silicon content
Molybdenum blue spectrophotometric method
Posted 2008-03-12
2008-09-01 implementation
National Development and Reform Commission issued
Foreword
YS/T 568 "zirconium, hafnium oxide chemical analysis method" is divided into 11 parts.
--- Part 1. Determination of zirconium oxide and hafnium content of mandelic acid gravimetric method;
--- Part 2. Determination of iron content sulfonic acid spectrophotometry;
--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method;
--- Part 4. Determination of aluminum content of chromium azure S- cylpyridinium chloride spectrophotometry;
--- Part 5. Determination of sodium content by flame atomic absorption spectrometry;
--- Part 6. Determination of the amount of titanium di Zhao DAM spectrophotometry;
--- Division 7. Determination of phosphorus content of antimony salt - ascorbic acid - phosphorus molybdenum blue spectrophotometric method;
--- Division 8. zirconia aluminum, calcium, magnesium, manganese, sodium, nickel, iron, titanium, zinc, molybdenum, vanadium, hafnium content - Inductively coupled plasma fat
Emission spectrometry;
--- Part 9. hafnium oxide of aluminum, calcium, magnesium, manganese, sodium, nickel, iron, titanium, zinc, molybdenum, vanadium, zirconium content - Inductively coupled plasma fat
Emission spectrometry;
--- Part 10. Determination of manganese content - Potassium periodate spectrophotometric method;
--- Part 11. Determination of α- linked furoylhydrazone nickel dioxime spectrophotometric method.
This is Part 3.
The partial replacement of YS/T 568.3-2006 "zirconium oxide, hafnium silicon content determination" (formerly GB/T 2590.3-1981).
This portion of YS/T 568.3-2006 compared to the main changes are as follows.
--- Added "7.1 repeatability" clause.
--- Added "8 Quality assurance and control" clause.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This part by the Beijing Nonferrous Metal Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting.
This section was drafted by the Beijing Nonferrous Metal Research Institute.
The main drafters of this section. Zhuo Tong Jian, Hu Zhenping.
This part of the standard replaces the previous editions are.
--- GB/T 2590.3-1981, YS/T 568.3-2006.
Zirconium oxide, hafnium oxide chemical analysis
Determination of silicon content
Molybdenum blue spectrophotometric method
1 Scope
This section specifies the determination method zirconia and hafnium silicon content.
This section applies to the determination of zirconium oxide and hafnium oxide and silicon content. Measurement range. 0.005% to 0.7%.
2 Method summary
Hydrofluoric acid in a high pressure sample Sample Dissolution apparatus dissolved, boric acid, ammonium molybdate after the solution was adjusted to pH 1 to 1.5, silicon to form a silicon
Molybdenum yellow, adding citric acid to eliminate phosphorus, arsenic interference with a 1-2-4 silicon molybdenum yellow acid is reduced to silicon molybdenum blue at 700nm wavelength spectrophotometer at
Measuring the absorbance.
3 Reagents
3.1 boric acid, pure class distinctions.
3.2 hydrofluoric acid (ρ1.15g/mL), pure class distinctions.
3.3 Ammonia (ρ0.90g/mL), pure class distinctions.
3.4 sulfate (ρ1.84g/mL), pure class distinctions.
3.5 ammonium molybdate solution (100g/L), pure class distinctions.
3.6 citric acid solution (200g/L), pure class distinctions.
3.7 amino-2-naphthol-4-sulfonic acid solution (1-2-4 acid). Weigh 0.05g1-2-4 acid, dissolved 100mL100g/L sodium sulfite solution
The time is now equipped with.
3.8 silicon standard stock solution.
Weigh 2.1393g pure silica [(Si) > 99.9%], placed in a platinum crucible, sodium carbonate and potassium carbonate was added 10g of melt mixing
Agent (2 + 1), mix well, on the torch to melt the crucible contents completely melted, continue to melt 10min. Cooling, leaching with hot water, heated to dissolve
Liquid clarification. Cooling water moved into 1000mL volumetric flask, and dilute to the mark. Store in a polyethylene bottle. This solution 1mL
Silicon-containing 1mg.
3.9 Silicon standard solution. Pipette 25.00mL silicon standard stock solution (3.8), placed in 250mL volumetric flask, dilute to the mark, shake
uniform. Store in a polyethylene bottle. This solution 1mL containing 100μg silicon.
4 Instrument
Spectrophotometer;
High pressure sample dissolution apparatus.
Step 5 Analysis
5.1 Sample
Table 1 sample was weighed, accurate to 0.0001g.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 568.3-2008_English be delivered?Answer: Upon your order, we will start to translate YS/T 568.3-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 568.3-2008_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 568.3-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 568.3-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 568.3-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|