US$139.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 556.1-2009: Methods for chemical analysis of antimony concentrates. Part 1: Determination of arsenic content. Cerium sulfate titration method Status: Valid YS/T 556.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 556.1-2009 | English | 139 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of antimony concentrates. Part 1: Determination of arsenic content. Cerium sulfate titration method
| Valid |
YS/T 556.1-2009
|
| YS/T 556.1-2006 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Antimony concentrates. Determination of antimony content
| Obsolete |
YS/T 556.1-2006
|
PDF similar to YS/T 556.1-2009
Basic data | Standard ID | YS/T 556.1-2009 (YS/T556.1-2009) | | Description (Translated English) | Methods for chemical analysis of antimony concentrates. Part 1: Determination of arsenic content. Cerium sulfate titration method | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | D42 | | Classification of International Standard | 73.060 | | Word Count Estimation | 5,547 | | Date of Issue | 2009-12-04 | | Date of Implementation | 2010-06-01 | | Older Standard (superseded by this standard) | YS/T 556.1-2006 | | Regulation (derived from) | MIIT [2009] No. 66 | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies: antimony concentrates Determination of antimony content. This standard applies to the amount of antimony in antimony concentrate measured. Measuring range: 5. 00 % 70. 00%. |
YS/T 556.1-2009: Methods for chemical analysis of antimony concentrates. Part 1: Determination of arsenic content. Cerium sulfate titration method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of antimony concentrates.Part 1. Determination of arsenic content.Cerium sulfate titration method
ICS 73.060
D42
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 556.1-2006
Methods for chemical analysis of antimony concentrates
Part 1. Determination of antimony content
Cerium sulfate titration
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 556-2009 "Methods for chemical analysis of antimony concentrate," a total of 16 parts.
--- Part 1. Determination of antimony content cerium sulfate titration;
--- Part 2. Determination of arsenic content potassium bromate titration;
--- Part 3. Determination of lead content by flame atomic absorption spectrometry;
--- Part 4. Wet water storage Gravimetric method;
--- Part 5. Determination of zinc content - Flame atomic absorption spectrometry;
--- Part 6. Determination of the amount of selenium by hydride generation - atomic fluorescence spectrometry;
--- Part 7. Determination of the amount of mercury atomic fluorescence spectrometry;
--- Part 8. Determination of sulfur content - Combustion neutralization method;
--- Part 9. Determination of the amount of gold fire assay;
--- Part 10. Determination of copper content - Flame atomic absorption spectrometry;
--- Part 11. Determination of cadmium content by flame atomic absorption spectrometry;
--- Part 12. Determination of bismuth content by flame atomic absorption spectrometry;
--- Part 13. Determination of nickel content by flame atomic absorption spectrometry;
--- Part 14. Determination of the amount of silver by flame atomic absorption spectrometry;
--- Part 15. antimony, tin measured by hydride generation - atomic fluorescence spectrometry;
--- Part 16. Determination of antimony metal content by inductively coupled plasma emission spectrometry.
This section YS/T 556 - Part 1.
"Antimony concentrates - Determination of antimony content" in this section instead of YS/T 556.1-2006 (formerly GB/T 15080.1-1994).
Compared with YS/T 556.1-2006, this part of the following changes.
--- Measuring cap extending from 65% to 70%;
--- Text format has been modified;
--- Complements the precision and quality assurance and control provisions.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This section is responsible for drafting unit. tin mine Twinkling Star Antimony Industry Co., Ltd., Beijing General Research Institute of Mining and Metallurgy.
This section is drafted. Tin Mine flash-antimony industry limited liability company.
Participated in the drafting of this section. Beijing Mining Research Institute, Guangzhou Nonferrous Metal Research Institute, Hunan Chenzhou Mining Co., Ltd.
The main drafters of this section. Cuide Hai, Song should ball, Yao Xingnuo, Liao Jingbo, Zhang Wei, Dai Fengying, Wu Shaobo.
This part of the standard replaces the previous editions are.
--- GB/T 15080.1-1994;
--- YS/T 556.1-2006.
Methods for chemical analysis of antimony concentrates
Part 1. Determination of antimony content
Cerium sulfate titration
1 Scope
This section YS/T 556 specifies the method for determination of antimony content in antimony concentrate.
This section applies to the determination of antimony content in antimony concentrate. Measurement range. from 5.00% to 70.00%.
2 Method summary
Samples with sulfuric acid - potassium decomposition filter paper made after carbonation reducing agent and co-solvent, in hydrochloric acid medium, add ferric phosphate masking off
Son, methyl orange as indicator, at 80 ℃ ~ 90 ℃ titration titration with cerium sulfate standard solution to the red end disappears.
3 Reagents
Unless otherwise indicated, the reagents used in this section refer to water and analytical grade and third grade water.
3.1 potassium sulfate.
3.2 sulfate (ρ1.84g/mL).
3.3 hydrochloride (ρ1.19g/mL).
3.4 Hydrogen peroxide (30%).
3.5 phosphoric acid (ρ1.70g/mL).
3.6 HCl (1 + 1).
3.7 methyl orange indicator (1g/L).
3.8 cerium sulfate standard titration solution [Ba Ce (SO4) 2 about 0.1mol/L].
3.8.1 preparation. Weigh 40.50g cerium sulfate [Ce (SO4) 2 · 4H2O], placed in 1000mL beaker, add 30mL sulfuric acid
(3.2), stir, gradually warming on a hot plate heated solvent into a paste, and take the white smoke of sulfuric acid for about 20min, remove the cooled, sulfur 140mL
Acid (3.2), and then slowly added 400mL of water, and stirred to dissolve clear, cooled and transferred to 1000mL volumetric flask, dilute to the mark with water,
Mix well.
3.8.2 Calibration. Weigh 0.2500g three pure antimony (Sb≥99.99%), were placed in 300mL Erlenmeyer flask with a small amount of water wet, add
Into 12mL sulfuric acid (3.2), heated and dissolved to clear, remove the cooling. The following operations carried out by 5.4.2,5.4.3.
Along with the calibration blank test.
According to equation (1) calculate the cerium sulfate standard titration solution (3.8) of the actual concentration.
ρ =
Vp 1- Vp () 0 × 121.76
(1)
Where.
ρ --- cerium sulfate standard titration solution (3.8) of the actual concentration in units of moles per liter (mol/L);
Vp 1 --- cerium sulfate titration antimony consumption standard titration solution (3.8) the volume in milliliters (mL);
V0 --- calibration blank solution volume consumed cerium sulfate standard titration solution (3.8) in milliliters (mL);
121.76 --- antimony molar mass in grams per mole (g/mol).
Average the three calibration results as cerium sulfate standard titration solution (3.8) of the actual concentration. Cerium sulfate standard parallel calibration consumed
Titration solution (3.8) very poor value does not exceed the volume of 0.10mL.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 556.1-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 556.1-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 556.1-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 556.1-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 556.1-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 556.1-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|