US$179.00 · In stock Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 534.1-2007: Chemical analysis methods of aluminium hydroxide. Part 1: Determination of moisture. Gravimetric method YS/T 534.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 534.1-2007 | English | 179 |
Add to Cart
|
2 days [Need to translate]
|
Chemical analysis methods of aluminium hydroxide. Part 1: Determination of moisture. Gravimetric method
| |
YS/T 534.1-2007
|
| YS/T 534.1-2006 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Chemical analysis methods of aluminium hydroxide. Determination of moisture. Gravimetric method
| Obsolete |
YS/T 534.1-2006
|
PDF similar to YS/T 534.1-2007
Basic data | Standard ID | YS/T 534.1-2007 (YS/T534.1-2007) | | Description (Translated English) | Chemical analysis methods of aluminium hydroxide. Part 1: Determination of moisture. Gravimetric method | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H12 | | Classification of International Standard | 71.060.40 | | Word Count Estimation | 5,544 | | Date of Issue | 2007-11-14 | | Date of Implementation | 2008-05-01 | | Older Standard (superseded by this standard) | YS/T 534.1-2006 | | Regulation (derived from) | NDRC Notice No. 77 of 2007 | | Issuing agency(ies) | National Development and Reform Commission | | Summary | This standard specifies the determination of moisture in aluminum hydroxide method. This standard applies to the determination of aluminum hydroxide in water. Measuring range: from 1. 00% to 20. 00%. |
YS/T 534.1-2007: Chemical analysis methods of aluminium hydroxide. Part 1: Determination of moisture. Gravimetric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods of aluminium hydroxide.Part 1. Determination of moisture.Gravimetric method
ICS 71.060.40
H12
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 534.1-2006
Methods for chemical analysis of aluminum hydroxide
Part 1. Determination of moisture content - Gravimetric method
Posted 2007-11-14
2008-05-01 implementation
National Development and Reform Commission issued
Foreword
YS/T 534-2007 "chemical analysis of aluminum hydroxide" is YS/T 534-2006 (formerly GB/T 6610-2003) amendments
It is divided into five parts.
--- Part 1. Determination of moisture content - Gravimetric method
--- Part 2. loss on ignition - Gravimetric method
--- Part 3. Determination of silica content molybdenum blue photometric
--- Part 4. Determination of iron oxide content phenanthroline spectrophotometry
Determination of sodium oxide content. Part 5 ---
This is Part 1.
The partial replacement of YS/T 534.1-2006 (formerly GB/T 6610.1-2003).
This part is YS/T 534.1-2006 "Chemical analysis methods of aluminum hydroxide - Part 1. Determination of moisture weight method," the editor
Finishing.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This part of the Aluminum Corporation of China Zhengzhou Research Institute is responsible for drafting.
This section drafted by the Aluminum Corporation of China Shandong Branch.
The main drafters of this section. Chengya Juan, Zhang Wencheng.
This part of the standard replaces the previous editions are.
--- YS/T 534.1-2006 (formerly GB/T 6610.1-2003).
Methods for chemical analysis of aluminum hydroxide
Part 1. Determination of moisture content - Gravimetric method
1 Scope
This section provides the determination of aluminum hydroxide in water.
This section applies to the determination of aluminum hydroxide in water. Measuring range. 1.00% to 20.00%.
2 principle of the method
Sample at 110 ℃ ± 5 ℃ drying 2h, to lose mass calculated moisture content.
3 Instrument
3.1 Analytical balance. accuracy 0.0001mg.
3.2 vacuum dryer. with the new desiccant activated alumina, the same vacuum dryer while cooling the appropriate number of weighing bottle. For example, the inner diameter
21cm vacuum dryer, while cooling the weighing bottle not more than six.
3.3 Oven. temperature can be controlled at 110 ℃ ± 5 ℃, can not be simultaneously dried in an oven other materials.
4 Sample
4.1 sample container should be filled with sealed, formerly known sample and mix well.
4.2 activated alumina activated. will be filled with activated alumina beaker was placed in an oven with a blower, drying at 300 ℃ ~ 350 ℃
3h ~ 4h, removed, and immediately placed in a vacuum desiccator (3.2), cooled to room temperature before use. Activated activated alumina is generally used 6 times
Determination of moisture.
Step 5 Analysis
5.1 Sample
Weigh 5.0g sample (4.1), accurate to 0.0001g.
5.2 Determination of the number of
Independently measured twice and averaged.
5.3 Determination
5.3.1 The weighing bottle opening portion, placed in an oven at 110 ℃ ± 5 ℃ of (3.3), the drying 1h, taken out, placed in a vacuum desiccator (3.2)
Cooled 30min, weighing, accurate to 0.0001g, repeat weighed to constant weight.
5.3.2 The sample (5.1) into the weighing bottle (5.3.1), and capped weighing, accurate to 0.0001g, partially open the cap, placed in drying
Box (3.3), the control temperature of 110 ℃ ± 5 ℃, drying 2h, taken in a vacuum dryer (3.2), cooled 30min, reclosable bottle weighing,
Accurate to 0.0001g, repeat weighed to constant weight.
Calculation results of the analysis of 6
According to a formula of moisture content (%).
100%
Where.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 534.1-2007_English be delivered?Answer: Upon your order, we will start to translate YS/T 534.1-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 534.1-2007_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 534.1-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 534.1-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 534.1-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|