HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YS/T 360.4-2011 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 360.4-2011: Methods of chemical analysis for ilmenite concentrate. Part 4: Determination of aluminum oxide content. EDTA titration
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 360.4-2011English189 Add to Cart 3 days [Need to translate] Methods of chemical analysis for ilmenite concentrate. Part 4: Determination of aluminum oxide content. EDTA titration Valid YS/T 360.4-2011

PDF similar to YS/T 360.4-2011


Standard similar to YS/T 360.4-2011

GB/T 2524   GB/T 3620.1   YS/T 298   YS/T 360.2   YS/T 360.3   YS/T 360.1   

Basic data

Standard ID YS/T 360.4-2011 (YS/T360.4-2011)
Description (Translated English) Methods of chemical analysis for ilmenite concentrate. Part 4: Determination of aluminum oxide content. EDTA titration
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H64
Classification of International Standard 77.120.90
Word Count Estimation 7,797
Date of Issue 2011-12-20
Date of Implementation 2012-07-01
Older Standard (superseded by this standard) YS/T 360-1994
Regulation (derived from) ?MIIT Announcement 2011 No.43
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the determination of the amount of alumina, ilmenite concentrates. This standard applies to the determination of the amount of alumina ilmenite concentrates. Measuring range of 0. 50% to 5. 00%.

YS/T 360.4-2011: Methods of chemical analysis for ilmenite concentrate. Part 4: Determination of aluminum oxide content. EDTA titration


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of chemical analysis for ilmenite concentrate.Part 4. Determination of aluminum oxide content.EDTA titration ICS 77.120.90 H64 People's Republic of China Nonferrous Metals Industry Standard Chemical analysis of ilmenite concentrates Part 4. determination of the amount of alumina EDTA titration Part 4. Determination ofaluminumoxidecontent- EDTAtitration 2011-12-20 release 2012-07-01 Implementation Issued by the Ministry of Industry and Information Technology of the People's Republic of China

Foreword

YS/T 360 "ilmenite concentrate chemical analysis method" is divided into six parts. - Part 1. Determination of titanium dioxide - Ammonium sulfate titration; - Part 2. Determination of total iron content - Potassium dichromate titration; - Part 3. Determination of the amount of ferrous oxide - Potassium dichromate titration; - Part 4. Determination of the amount of alumina - EDTA titration; - Part 5. Determination of silicon dioxide - Mo - Mo - blue spectrophotometric method; Part 6. Determination of calcium oxide, magnesium oxide, and phosphorus content - Plasma emission spectrometric method. This section is part 3 of YS/T 360. This standard is owned by the National Committee for the Standardization of Nonferrous Metals (SAC/TC243). The drafting unit of this standard. Zunyi Titanium Industry Co., Ltd., Jinchuan Group Co., Ltd., Yunnan Xinli Nonferrous Metals Co., Ltd., Fushun Titanium Industry Co., Ltd., China Nonferrous Metals Industry Standard Measurement Quality Institute. The main drafters of this standard. to Lun Qiang, Luo Lin, Yang Xuexin, Yu Shengjie, Zhang Jiangfeng, Zhang Jian, Zhuang Jun. Chemical analysis of ilmenite concentrates Part 4. determination of the amount of alumina EDTA titration

1 Scope

This part of YS/T 360 specifies the determination method for the amount of alumina in ilmenite concentrates. This part is applicable to the determination of alumina in ilmenite concentrate, the determination range is 0.50% ~ 5.00%.

2 method summary

The sample was melted with sodium hydroxide and extracted with dilute hydrochloric acid. Hexamethylenetetramine precipitates aluminum, titanium and iron, and the separation of magnesium, calcium and manganese and other elements. Will precipitate low temperature ashing, and then melted by sodium hydroxide, hot water leaching. Separation and removal of titanium and other elements. Remove part of the test solution, in weak acid solution, Addition of excess EDTA complex aluminum. At pH 6.0 or so, with excess xylenol orange as an indicator, excess EDTA was titrated with a zinc standard solution. Then After replacing the EDTA in the complex with sodium fluoride, titration with zinc standard titration to stabilize the purple is the end point, so that oxygen The amount of aluminum. Tin content of less than 0.2mg, chromium less than 1mg, vanadium less than 0.05mg does not affect the determination. When the amount of vanadium is more than 0.05 mg, sulfuric acid is used Ferrous ammonium elimination interference.

3 reagent

3.1 sodium hydroxide, excellent grade pure. 3.2 Sodium peroxide. 3.3 Ethanol. 3.4 ammonia (ρ about 0.90g/mL). 3.5 Ammonia (1 1). 3.6 Hydrochloric acid (1 1). 3.7 hexamethylenetetramine solution (250 g/L). 3.8 Ammonium chloride wash solution (20g/L). Add 1 to 2 drops of ammonia (3.5) per 100mL of washing solution. 3.9 ammonium ferrous sulfate solution (1g/L). When used with the current allocation. 3.10 Ethylenediamine tetraacetic acid disodium (EDTA) solution (0.02 mol/L). Weigh 3.72 g of disodium ethylenediaminetetraacetate (Na2C10H16O8N2 · 2H2O), dissolved in 1000 mL of water and mixed. 3.11 methyl orange solution (1g/L). 3.12 xylenol orange solution (2g/L). stored in a brown bottle, effective within a week. 3.13 Sodium fluoride solution (40 g/L). 3.14 Acetic acid monoacetate buffer solution (pH 6.0 ± 0.2). 300 g of ammonium acetate was weighed in 500 mL of water, filtered, 12.3 mL Glacial acetic acid, diluted with water to 1000mL, mix well. (Corrected with acidity meter). 3.15 zinc standard titration solution (0.01000mol/L). Weigh 1.6276g zinc oxide (spectral purity or reference reagent), placed in 300mL Beaker, wet with water, add 20mL hydrochloric acid (3.6), slowly dissolve the heat and evaporate to a volume of 3mL ~ 5mL, into the.2000mL

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 360.4-2011_English be delivered?

Answer: Upon your order, we will start to translate YS/T 360.4-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 360.4-2011_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 360.4-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.