HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YS/T 325.5-2009 English PDF

US$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 325.5-2009: Methods for chemical analysis of nickel-copper alloy. Part 5: Determination of aluminum content. The Na2EDTA titrimetric method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 325.5-2009English159 Add to Cart 3 days [Need to translate] Methods for chemical analysis of nickel-copper alloy. Part 5: Determination of aluminum content. The Na2EDTA titrimetric method Valid YS/T 325.5-2009

PDF similar to YS/T 325.5-2009


Standard similar to YS/T 325.5-2009

YS/T 252.6   GB/T 3884.2   GB/T 3884.1   YS/T 325.3   YS/T 325.4   YS/T 325.1   

Basic data

Standard ID YS/T 325.5-2009 (YS/T325.5-2009)
Description (Translated English) Methods for chemical analysis of nickel-copper alloy. Part 5: Determination of aluminum content. The Na2EDTA titrimetric method
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H13
Classification of International Standard 77.120.40
Word Count Estimation 6,673
Date of Issue 2009-12-04
Date of Implementation 2010-06-01
Older Standard (superseded by this standard) YS/T 325-1994
Regulation (derived from) MIIT [2009] No. 66
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies: nickel-copper alloy aluminum content measurement methods. This standard applies to the amount of nickel- copper aluminum alloy measurement, measuring range: from 1. 00% to 7. 00%.

YS/T 325.5-2009: Methods for chemical analysis of nickel-copper alloy. Part 5: Determination of aluminum content. The Na2EDTA titrimetric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of nickel-copper alloy.Part 5. Determination of aluminum content.The Na2EDTA titrimetric method ICS 77.120.40 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 325-1994 Nickel-copper alloys - Part 5. Determination of aluminum content N Rao 2EDTA titration Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 325-2009 "nickel-copper alloy chemical analysis method" a total of six sections. --- Part 1. Determination of nickel content Na2EDTA titration --- Part 2. Determination of copper content - Gravimetric method electrolysis --- Part 3. Determination of iron content by flame atomic absorption spectrometry --- Part 4. Determination of manganese content by flame atomic absorption spectrometry --- Part 5. Determination of aluminum content Na2EDTA titration --- Part 6. Determination of the amount of titanium di Zhao DAM spectrophotometry This section YS/T Part 5 325. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This section is responsible for drafting unit. aluminum Shenyang Nonferrous Metals Processing Co., Ltd. Participated in the drafting of this section. Baoji Titanium Group Limited, CRIMM. The main drafters of this section. Hao Zhang, Li Yamin, Liu Yan, Liu Ting, Xiao Xiang, Yang Weiwei, Yang Lin. Nickel-copper alloys - Part 5. Determination of aluminum content N Rao 2EDTA titration

1 Scope

YS/T of the provisions of the section 325 determination of the amount of nickel and copper in aluminum alloys. This section applies to the determination of the amount of nickel and copper in aluminum alloys. Measuring range. 1.00% - 7.00%.

2 principle of the method

Sample dissolved in nitric acid, the solution was adjusted pH4.2 ~ pH4.4, the hydroxylamine hydrochloride, bitter almond presence of an acid, ammonium benzoate and aluminum generate Shen precipitate. The precipitate was dissolved with hydrochloric acid, an excess of Na2EDTA, so that the aluminum complex. Zinc standard solution titration titration of excess Na2EDTA. Sodium fluoride, zinc standard titration solution and then titrated been released Na2EDTA.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 sodium fluoride. 3.2 nitric acid (1 + 1). 3.3 HCl (1 + 1). 3.4 hydrochloric acid (1 + 2). 3.5 hydrochloride [Ba (HCl) = 1mol/L]. 3.6 Ammonia (ρ0.90g/mL). 3.7 buffer solution. 125g of anhydrous sodium acetate is dissolved in water, was added 130mL of hydrochloric acid (3.3), diluted with water to 1000mL, mixed uniform. This solution is approximately pH4.5. 3.8 hydroxylamine hydrochloride solution (100g/L). 3.9 mandelic acid solution (100g/L). 3.10 ammonium benzoate solution (80g/L). 3.11 Ammonium benzoate lotion. A 400mL water, 50mL ammonium benzoate solution (3.10) and 50mL hydroxylamine hydrochloride (3.8) and mix. 3.12 hexamethylenetetramine solution (300g/L). 3.13 acetic acid (1 + 1). with 36% acetic acid preparation. 3.14 pairs nitrophenol solution (2g/L). 3.15 XO solution (2g/L). 3.16 disodium ethylenediaminetetraacetate (by Na2EDTA) standard solution [Ba (C10H14N2O8Na2 · 2H2O) = 0.025mol/L]. will 9.3gNa2EDTA dissolved in 200mL hot water, cooling transferred to 1000mL volumetric flask, dilute with water to volume, and mix. 3.17 aluminum standard solution. Weigh 1.0000g of aluminum (aluminum mass fraction ≥99.95%) placed in 150mL Teflon beaker, 20mL was added sodium hydroxide solution (300g/L), heated slowly to dissolve completely cooled. With hydrochloric acid (3.3) adjusted to precipitate disappeared, clear solution Che, then the solution is acidic, cooled and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg Aluminum (ρ). 3.18 Zinc Standard Solution [Ba (Zn) = 0.020mol/L]