US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 281.2-2011: Methods for chemical analysis of cobalt. Part 2: Determination of aluminum content. Chromeazurol S spectrophotometry Status: Valid YS/T 281.2: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 281.2-2011 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of cobalt. Part 2: Determination of aluminum content. Chromeazurol S spectrophotometry
| Valid |
YS/T 281.2-2011
|
YS/T 281.2-1994 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Cobalt - Determination of aluminium content - Chromazurol S-P-octyl polyethylene glycol phenyl ether-tetradecyl phridinium bromine mixed micellar solubilization spectrophotometric method
| Obsolete |
YS/T 281.2-1994
|
PDF similar to YS/T 281.2-2011
Basic data Standard ID | YS/T 281.2-2011 (YS/T281.2-2011) | Description (Translated English) | Methods for chemical analysis of cobalt. Part 2: Determination of aluminum content. Chromeazurol S spectrophotometry | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H13 | Classification of International Standard | 77.120.70 | Word Count Estimation | 7,754 | Date of Issue | 2011-12-20 | Date of Implementation | 2012-07-01 | Older Standard (superseded by this standard) | YS/T 281.2-1994 | Regulation (derived from) | ?MIIT Announcement 2011 No.43 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the method for the determination of cobalt in aluminum content. This standard applies to the determination of cobalt in aluminum content. Measuring range: 0. 00030% to 0. 0050%. |
YS/T 281.2-2011: Methods for chemical analysis of cobalt. Part 2: Determination of aluminum content. Chromeazurol S spectrophotometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of cobalt.Part 2. Determination of aluminum content.Chromeazurol S spectrophotometry
ICS 77.120.70
H13
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 281.2-1994
Methods for chemical analysis of cobalt - Part 2. Determination of aluminum content
Chromium Azure S Spectrophotometry
Part 2. Determinationofaluminumcontent-
Issued on. 2011-12-20
2012-07-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 281 "cobalt chemical analysis method" is divided into the following 20 sections.
--- Part 1. Determination of iron content sulfonic acid spectrophotometry
--- Part 2. Determination of the amount of chrome aluminum Azure S Spectrophotometry
--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method
--- Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method
--- Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method
--- Part 6. Determination of magnesium content - Flame atomic absorption spectrometry
--- Part 7. Determination of zinc content - Flame atomic absorption spectrometry
--- Part 8. Determination of cadmium content by flame atomic absorption spectrometry
--- Part 9. Determination of lead content - flame atomic absorption spectrometry
--- Part 10. Determination of nickel content by flame atomic absorption spectrometry
--- Part 11. Flame atomic copper, manganese content absorption spectrometry
--- Part 12. arsenic, antimony, bismuth, tin, lead and determining the amount of electrothermal atomic absorption spectrometry
--- Part 13. Determination of sulfur content high frequency induction furnace combustion infrared absorption method
--- Part 14. Determination of the amount of carbon high-frequency induction furnace combustion infrared absorption method
--- Part 15. arsenic, antimony, bismuth contents - Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 16. Determination of DC arc atomic arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum, magnesium content of the emitted light
Spectroscopy
--- Part 17. aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead, bismuth content - Inductively Coupled Plasma Mass Spectrometry
--- Part 18. Determination of sodium content by flame atomic absorption spectrometry
--- Part 19. calcium, magnesium, manganese, iron, cadmium, zinc content - Inductively coupled plasma atomic emission spectrometry
--- Part 20. Determination of oxygen content - Impulse - infrared absorption method
This section YS/T 281 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The partial replacement of YS/T 281.2-1994 "Methods for chemical analysis of cobalt chrome azure S spectrophotometric determination of aluminum content." versus
YS/T 281.2-1994 compared, this section there are major changes as follows.
--- Measured by the scope of 0.0003% ~ 0.002% revised to 0.00030% to 0.0050%;
--- Text format has been modified, supplemented with quality assurance and control provisions, increase the repeatability limit and reproducibility limit;
--- Complement the test reporting requirements.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
This standard is drafted by. Jinchuan Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy.
This section is responsible for drafting unit. Jinchuan Group Limited.
Participated in the drafting of this section. Beijing Mining Research Institute, Zhejiang Huayou Cobalt Co. Ltd..
The main drafters of this section. hair Zhang Zhi, Li Xikai, Lvqing Cheng, Dong Liping, Pan Meirong, Feng advanced color Ruan Gui Li Gram.
This part of the standard replaces the previous editions are.
--- YS/T 281.2-1994.
Methods for chemical analysis of cobalt - Part 2. Determination of aluminum content
Chromium Azure S Spectrophotometry
Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Make
With those who have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This section YS/T 281 provides for determination of cobalt in aluminum content.
This section applies to the determination of cobalt in aluminum content. Measurement range. 0.00030% to 0.0050%.
2 Method summary
Sample was dissolved in nitric acid at pH4.6 ~ 5.2, the use of ethyl benzoate and aluminum benzoate cobalt extraction separation. With hydrochloric acid trans
The organic phase was extracted aluminum. Aluminum and CAS S- bromo emulsifier OP- cylpyridinium form a complex at 610nm wavelength spectrophotometer
Measured absorbance.
3 Reagents
Unless otherwise specified, the reagents were analytical reagent solution preparation and analysis are secondary distilled water or equivalent purity test
Room with water.
3.1 hydrochloric acid (ρ = 1.19g/mL) of high purity.
3.2 nitric acid (ρ = 1.42g/mL) of high purity.
3.3 ammonium hydroxide (ρ = 0.90g/mL) of high purity.
3.4 hydrochloride (11).
3.5 hydrochloric acid (119).
3.6 ammonium hydroxide solution (120), stored in a plastic bottle.
3.7 nitric acid (32).
3.8 Chromium Azure S solution (1g/L). Weigh 0.20g Chromium Azure S dissolved in 100mL of water, diluted to 200mL with ethanol.
3.9 polyethylene glycol octylphenyl ether (emulsifier OP) solution (1999).
Bromo cylpyridinium 3.10 (TPB) solution (4g/L).
3.11 acetic acid - ammonium acetate buffer solution. A 485mL solution of ammonium acetate (4mol/L) was diluted to 500mL with acetic acid (4mol/L),
Mix well.
3.12 ammonium benzoate solution (120g/L). Weigh 12g of ammonium benzoate was dissolved in water, adding 2 to 3 drops of ammonium hydroxide (3.3) dissolved End
Full, dilute with water to 100mL.
3.13 Ammonium benzoate lotion (20g/L). Weigh 2g ammonium benzoate was dissolved in 100mL of water, carefully adjust the pH with dilute hydrochloric acid on pH meter
Is between 4.6 to 4.8.
3.14 benzoic acid - ethyl acetate solution (50g/L). Weigh 25g of benzoic acid dissolved in ethyl acetate, diluted to 500mL with ethyl acetate.
3.15 hydroxylamine hydrochloride solution (100g/L). the time is now equipped with.
3.16 ascorbic acid solution (10g/L). the time is now equipped with.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 281.2-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 281.2-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 281.2-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 281.2-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 281.2-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 281.2-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|