US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 281.11-2011: Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry Status: Valid YS/T 281.11: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 281.11-2011 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry
| Valid |
YS/T 281.11-2011
|
YS/T 281.11-1994 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Cobalt - Determination of copper and manganese contents - Flame atomic absorption spectrophotometric method
| Obsolete |
YS/T 281.11-1994
|
PDF similar to YS/T 281.11-2011
Basic data Standard ID | YS/T 281.11-2011 (YS/T281.11-2011) | Description (Translated English) | Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H13 | Classification of International Standard | 77.120.70 | Word Count Estimation | 6,687 | Date of Issue | 2011-12-20 | Date of Implementation | 2012-07-01 | Older Standard (superseded by this standard) | YS/T 281.11-1994 | Regulation (derived from) | ?MIIT Announcement 2011 No.43 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the cobalt copper, Determination of manganese content. This standard applies to cobalt copper, Determination of manganese content. Measuring range: 0. 00050% to 0. 30%. |
YS/T 281.11-2011: Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of cobalt.Part 11. Determination of copper and manganese contents.Flame atomic absorption spectrometry
ICS 77.120.70
H13
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 281.11-1994
Methods for chemical analysis of cobalt
Part 11. copper, manganese contents
Flame Atomic Absorption Spectrometry
Part 11. Determinationofcopperandmanganesecontents-
Issued on. 2011-12-20
2012-07-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 281 "cobalt chemical analysis method" is divided into the following 20 sections.
--- Part 1. Determination of iron content sulfonic acid spectrophotometry
--- Part 2. Determination of the amount of chrome aluminum Azure S Spectrophotometry
--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method
--- Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method
--- Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method
--- Part 6. Determination of magnesium content - Flame atomic absorption spectrometry
--- Part 7. Determination of zinc content - Flame atomic absorption spectrometry
--- Part 8. Determination of cadmium content by flame atomic absorption spectrometry
--- Part 9. Determination of lead content - flame atomic absorption spectrometry
--- Part 10. Determination of nickel content by flame atomic absorption spectrometry
--- Part 11. Flame atomic copper, manganese content absorption spectrometry
--- Part 12. arsenic, antimony, bismuth, tin, lead and determining the amount of electrothermal atomic absorption spectrometry
--- Part 13. Determination of sulfur content high frequency induction furnace combustion infrared absorption method
--- Part 14. Determination of the amount of carbon high-frequency induction furnace combustion infrared absorption method
--- Part 15. arsenic, antimony, bismuth contents - Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 16. Determination of DC arc atomic arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum, magnesium content of the emitted light
Spectroscopy
--- Part 17. aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead, bismuth content - Inductively Coupled Plasma Mass Spectrometry
--- Part 18. Determination of sodium content by flame atomic absorption spectrometry
--- Part 19. calcium, magnesium, manganese, iron, cadmium, zinc content - Inductively coupled plasma atomic emission spectrometry
--- Part 20. Determination of oxygen content - Impulse - infrared absorption method
This section YS/T 281 Part 11.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The partial replacement of YS/T 281.11-1994 "cobalt chemical analysis by flame atomic absorption spectrometric method for the determination of copper, manganese content." versus
YS/T 281.11-1994 compared, this section there are major changes as follows.
--- Measured by the scope of 0.0005% to 0.15% revised to 0.00050% to 0.30%;
--- Text format has been modified, supplemented with quality assurance and control provisions, increase the repeatability limit and reproducibility limit;
--- Complement the test reporting requirements.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
This standard is drafted by. Jinchuan Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy.
This section is responsible for drafting unit. Jinchuan Group Limited.
Participated in the drafting of this section. Beijing Mining Research Institute, Shenzhen High-tech Co., Ltd. Grammy.
The main drafters of this section. Wen Jie accounted for, Lvqing Cheng, Zhang Jihong, Zhu Yujiang, advanced Feng, Jiang Tao seeking, pear Yan, He Xianda.
This part of the standard replaces the previous editions are.
--- YS/T 281.11-1994.
Methods for chemical analysis of cobalt
Part 11. copper, manganese contents
Flame Atomic Absorption Spectrometry
Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Make
With those who have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This section YS/T 281 provides for determination of copper, cobalt, manganese content.
This section applies to cobalt Determination of copper, manganese content. Measurement range. 0.00050% to 0.30%.
2 principle of the method
Sample decomposition with nitric acid, in dilute nitric acid medium, using air - acetylene flame atomic absorption spectrometer, respectively, at a wavelength of 324.7nm
Absorbance was measured at copper, manganese absorbance was measured at 279.5nm.
In the standard solution and sample solution should contain the same concentration of cobalt matrix.
3 Reagents
Unless otherwise specified, the reagents were analytical reagent solution preparation and analysis are secondary distilled water or equivalent purity test
Room with water.
3.1 cobalt (wCo≥99.98%, wCu < 0.0001%, wMn < 0.0001%).
3.2 nitric acid (ρ = 1.42g/mL), pure class distinctions.
3.3 nitric acid (11).
3.4 nitric acid (119).
3.5 copper, manganese standard stock solution. Weigh copper (wCu > 99.95), manganese metal (wMn > 99.95) each 0.8000g, were placed
Two 400mL beaker, 40mL of nitric acid was added each (3.3), cover sheet pan and heated until complete dissolution, micro-boiling rid of nitrogen oxides, taking
Under water and dish washing table Beibi, cooled to room temperature. They were transferred to 1000mL volumetric flask with water to volume, and mix. The solution 1mL
Respectively containing 800μg copper, manganese.
3.6 mixed standard solution. Pipette each 10.00mL copper, manganese standard stock solution (3.5) in 100mL flask with water to volume, and mix.
This solution 1mL containing 80μg respectively, copper, manganese.
4 Instrument
Atomic absorption spectrometer, with copper, manganese hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Sensitivity. basically the same test solution and measurement solution, characteristic concentration copper, manganese should not exceed 0.05μg/mL.
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance;
The lowest concentration of standard solution used (instead of "zero" standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum concentration
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 281.11-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 281.11-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 281.11-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 281.11-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 281.11-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 281.11-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|