US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 276.7-2011: Methods for chemical analysis of indium. Part 7: Determination of lead content. Flame atomic absorption spectrometry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 276.7-2011 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of indium. Part 7: Determination of lead content. Flame atomic absorption spectrometry
| Valid |
YS/T 276.7-2011
|
PDF similar to YS/T 276.7-2011
Basic data | Standard ID | YS/T 276.7-2011 (YS/T276.7-2011) | | Description (Translated English) | Methods for chemical analysis of indium. Part 7: Determination of lead content. Flame atomic absorption spectrometry | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H13 | | Classification of International Standard | 77.120.99 | | Word Count Estimation | 7,765 | | Date of Issue | 2011-12-20 | | Date of Implementation | 2012-07-01 | | Older Standard (superseded by this standard) | YS/T 276.6-1994 | | Regulation (derived from) | ?MIIT Announcement 2011 No.43 | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies the determination of the amount of indium in the lead. This standard applies to the determination of the amount of indium lead. Measuring range: 0. 00030% to 0. 200%. |
YS/T 276.7-2011: Methods for chemical analysis of indium. Part 7: Determination of lead content. Flame atomic absorption spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of indium.Part 7. Determination of lead content.Flame atomic absorption spectrometry
ICS 77.120.99
H13
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 276.6-1994
Methods for chemical analysis of indium
Part 7. Determination of lead content
Flame Atomic Absorption Spectrometry
Part 7. Determinationofleadcontent-
Issued on. 2011-12-20
2012-07-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 276 "indium chemical analysis methods," including a total of 11 parts.
--- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;
--- Part 2. Determination of tin content Phenylfluorone - bromo cetyl trimethylamine spectrophotometry;
--- Part 3. Determination of the amount of thallium methyl green spectrophotometry;
--- Part 4. Determination of the amount of chrome aluminum Azure S Spectrophotometry;
--- Part 5. Determination of iron content of 1. electrothermal atomic absorption spectrometry
Method 2. Flame atomic absorption spectrometry;
--- Part 6. copper, cadmium, zinc content - Flame atomic absorption spectrometry;
--- Part 7. Determination of lead content by flame atomic absorption spectrometry;
--- Part 8. Determination of bismuth content 1. Hydride Generation - Atomic Fluorescence Spectrometry
Method 2. Flame atomic absorption spectrometry;
--- Part 9. Determination of the amount of indium Na2EDTA titration;
--- Part 10. bismuth, aluminum, lead, iron, copper, cadmium, tin, thallium content - Inductively coupled plasma atomic emission spectrometry;
--- Part 11. arsenic, aluminum, lead, iron, copper, cadmium, tin, thallium, zinc, bismuth content - Inductively Coupled Plasma Mass Spectrometry.
This section drafted in accordance with the rules of GB/T 1.1 is given.
This section YS/T Section 7276 of.
The partial replacement of YS/T 276.6-1994 "Methods for chemical analysis of indium atomic absorption spectrophotometry lead content", and YS/T 276.6
-1994 Compared to the main changes are as follows.
--- Changed the extracting agent, with butyl acetate instead of methyl isobutyl ketone;
--- Measuring range extended from 0.0010% - from 0.025 to 0.00030% - 0.200%;
--- Complements the precision, quality assurance and control provisions;
--- Complements the "test report" requirement.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This standard is drafted by. Zhuzhou Smelter Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy.
This section is drafted. Guangxi China Tin Group Co., Ltd.
Participated in the drafting of this section. Zhuzhou Smelter Group Co., Ltd., MCC Huludao Nonferrous Metals Group Co., Ltd.
Drafters of this section. Tan Zuo Ming Yang concept of new, Luopei Zhen, Liang Bowen, Zhang Zhizhong, Zhao Shu Mei, Luo Gan, Zhu-fan, Liu Jihong, the more segments.
This part of the standard replaces the previous editions are.
--- YS/T 276.6-1994;
--- GB 8221.6-1987.
Methods for chemical analysis of indium
Part 7. Determination of lead content
Flame Atomic Absorption Spectrometry
Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues.
Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This section provides the determination of indium in lead content.
This section applies to the determination of indium in lead content. Determination of the range of 0.00030% to 0.200%.
2 principle of the method
Sample decomposition with hydrobromic acid, butyl acetate, indium extraction and separation, the aqueous phase atomic absorption spectrometer at a wavelength of 283.3nm, Determination of lead
Absorbance.
3 Reagents
Unless otherwise indicated, used in the analysis confirmed only for the gifted class pure reagents and distilled or deionized water or equivalent purity.
3.1 butyl acetate.
3.2 hydrochloride (ρ1.19g/mL).
3.3 hydrobromide (ρ1.42g/mL).
Nitrate 3.4 (ρ1.42g/mL).
3.5 hydrobromic acid solution (5.5mol/L). Pipette 404mL hydrobromide (3.3) in 500mL volumetric flask, dilute with water to volume, and mix.
3.6 nitric acid solution (14).
3.7 lead standard stock solution. Weigh 1.0000g cleaned surface of metallic lead (w≥99.99%) placed in 250mL beaker, add
10mL of nitric acid (3.6), at low temperature to dissolve completely get rid of nitrogen oxides boiling, cooling is removed and transferred to 1000mL volumetric flask, washed with water
Dilute to volume, and mix. 1mL solution containing 1mg lead.
3.8 Lead standard solution. Pipette 20.00mL lead standard stock solution (3.7) placed in 200mL flask, add 10mL of nitric acid
(3.6), dilute to the mark and mix. This solution 1mL containing 100μg lead.
4 Instrument
Atomic absorption spectrometer, with a lead hollow cathode lamp.
Under instrument conditions, who can achieve the following indicators atomic absorption spectrometer can be used.
--- Characteristic concentration. In line with the measurement of the sample solution matrix solution, characterized in lead concentration should not exceed 0.25μg/mL.
--- Precision. measuring the absorbance of 11 with the highest concentration of the standard solution, the relative standard deviation should not exceed 1.0%; the lowest concentration
Degree standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the relative standard deviation should not exceed 0.5%.
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 276.7-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 276.7-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 276.7-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 276.7-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|