US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 254.6-2011: Methods for chemical analysis of beryllium concentrate and beryl. Part 6: Determination of calcium oxide content. Flame atomic absorption spectrometry Status: Valid YS/T 254.6: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 254.6-2011 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of beryllium concentrate and beryl. Part 6: Determination of calcium oxide content. Flame atomic absorption spectrometry
| Valid |
YS/T 254.6-2011
|
YS/T 254.6-1994 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods for chemical analysis of beryllium concentrates-beryl The atomic absorption spectrophotometric method for the determination of calcium oxide content
| Obsolete |
YS/T 254.6-1994
|
PDF similar to YS/T 254.6-2011
Basic data Standard ID | YS/T 254.6-2011 (YS/T254.6-2011) | Description (Translated English) | Methods for chemical analysis of beryllium concentrate and beryl. Part 6: Determination of calcium oxide content. Flame atomic absorption spectrometry | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | D43 | Classification of International Standard | 73.060 | Word Count Estimation | 6,648 | Date of Issue | 2011-12-20 | Date of Implementation | 2012-07-01 | Older Standard (superseded by this standard) | YS/T 254.6-1994 | Regulation (derived from) | ?MIIT Announcement 2011 No.43 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the beryllium ore, Determination of calcium oxide content of beryl. This standard applies to beryllium ore, determination of beryl calcium oxide. Measuring range: 0. 05% to 2. 00%. |
YS/T 254.6-2011: Methods for chemical analysis of beryllium concentrate and beryl. Part 6: Determination of calcium oxide content. Flame atomic absorption spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of beryllium concentrate and beryl.Part 6. Determination of calcium oxide content.Flame atomic absorption spectrometry
ICS 73.060
D43
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 254.6-1994
Beryllium ore, beryl chemical analysis
Part 6. Determination of calcium oxide content
Flame Atomic Absorption Spectrometry
Part 6. Determinationofcalciumoxidecontent-
Issued on. 2011-12-20
2012-07-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 254 "of beryllium ore, beryl chemical analysis method" is divided into seven parts.
--- Part 1. Determination of the amount of beryllium oxide phosphate gravimetric method;
--- Part 2. iron oxide contents - EDTA titration sulfosalicylic acid spectrophotometric method;
--- Part 3. Determination of phosphorus content Molybdovanadophosphoric acid spectrophotometry;
--- Part 4. Determination of the amount of lithium oxide flame atomic absorption spectrometry;
--- Part 5. Determination of the amount of fluorine ion selective electrode method;
--- Part 6. Determination of calcium oxide content by flame atomic absorption spectrometry;
--- Part 7. moisture content - Gravimetric method.
This section YS/T Part 6 254.
The partial replacement of YS/T 254.6-1994 "beryllium concentrates - beryl chemical analysis by flame atomic absorption spectrometry determination of calcium oxide
Amount "(formerly GB/T 5870.6-1986).
Section compared with YS/T 254.6-1994 The main changes are as follows.
--- The "lanthanum - strontium mixed solution" to "lanthanum solution";
--- Increased repeatability terms;
--- Text format has been re-edited, an increase of quality assurance and control provisions.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is drafted. Xinjiang Institute of Nonferrous Metals, Hunan Nonferrous Metal Research Institute, Xinjiang Alashankou CIQ.
The main drafters of this section. Guan Yuzhen, Xu Jun, Wang Hongchuan, Pangwen Lin, Huang Ping, Lv Xiaohua, Simultaneously..
This part of the standard replaces the previous editions are.
--- GB/T 5870.6-1986, YS/T 254.6-1994.
Beryllium ore, beryl chemical analysis
Part 6. Determination of calcium oxide content
Flame Atomic Absorption Spectrometry
1 Scope
This section YS/T 254 provisions of the beryllium ore, beryl Determination of calcium oxide content.
This section applies to beryllium ore, beryl determination of calcium oxide. Measurement range of 0.05% to 2.00%.
2 Method summary
Sample with ammonium hydrogen - hydrofluoric acid decomposition, heightening smoke fluorine perchlorate in hydrochloric acid medium, lanthanum release agents, in AAS
Spectrum at a wavelength of 422.7nm, air - acetylene flame measured calcium oxide.
3 Reagents
3.1 ammonium hydrogen fluoride.
3.2 perchloric acid (ρ1.67g/mL).
3.3 Hydrofluoric acid (ρ1.13g/mL).
3.4 hydrochloric acid solution (11) pure class distinctions.
3.5 lanthanum solution. Weigh 29.3g of lanthanum oxide (of La2O3) (high purity grade), placed in 250mL beaker, a solution of hydrochloric acid was added slowly with stirring
(3.4) to dissolve lanthanum oxide, heated to boiling clear, cooled to room temperature, the solution is transferred 500mL volumetric flask, dilute to the mark with water,
Mix well.
Calcium oxide 3.6 standard stock solution. Weigh 1.7850g ignition advance 1.5h at 300 ℃ ~ 400 ℃ and placed in a desiccator and cooled to
Calcium carbonate at room temperature [w (CaCO3) ≥99.9%], placed in 250mL beaker. Was added 100mL of water, cover the dish table, from the cup mouth slowly add
Into 30mL hydrochloric acid solution (3.4), heated to dissolve all of the calcium carbonate, the carbon dioxide purge boil, cooled to room temperature, washed with water purge sheet pan, shift
Into 1000mL volumetric flask, dilute with water to volume, and mix. This solution corresponds to 1000μg 1mL calcium oxide.
3.7 calcium oxide standard solution. Pipette 100.00mL calcium oxide standard stock solution (3.6), placed 1000mL volumetric flask, dilute with water
Diluted to volume, and mix. This solution was equivalent to 100μg 1mL calcium oxide.
4 Instrument
Atomic absorption spectrometer, with a calcium hollow cathode lamp.
Under optimum conditions the instrument, those who can achieve the following indicators can be used.
--- Characteristic concentration. In line with the determination of the solution matrix solution, characterized in calcium concentration should not exceed 0.10μg/mL.
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance;
With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum
The average concentration of 0.5% absorbance.
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 254.6-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 254.6-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 254.6-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 254.6-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 254.6-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 254.6-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|