HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

YS/T 227.6-2010 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 227.6-2010: Methods for chemical analysis of tellurium. Part 6: Determination of copper content. Solid-liquid separate-flame atomic absorption spectrophotometry

YS/T 227.6: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 227.6-2010English209 Add to Cart 3 days [Need to translate] Methods for chemical analysis of tellurium. Part 6: Determination of copper content. Solid-liquid separate-flame atomic absorption spectrophotometry   YS/T 227.6-2010
YS/T 227.6-1994English199 Add to Cart 2 days [Need to translate] Determination of copper content in tellurium. Neocuproine Chloroform extraction photometric method Obsolete YS/T 227.6-1994

PDF similar to YS/T 227.6-2010


Standard similar to YS/T 227.6-2010

GB/T 3884.2   GB/T 3884.1   YS/T 252.1   YS/T 227.12   YS/T 227.1   YS/T 227.10   

Basic data

Standard ID YS/T 227.6-2010 (YS/T227.6-2010)
Description (Translated English) Methods for chemical analysis of tellurium. Part 6: Determination of copper content. Solid-liquid separate-flame atomic absorption spectrophotometry
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H13
Classification of International Standard 77.120.99
Word Count Estimation 6,677
Date of Issue 2010-11-22
Date of Implementation 2011-03-01
Older Standard (superseded by this standard) YS/T 227.6-1994
Regulation (derived from) MIIT (2010) No. 126
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the tellurium copper content determination. This standard applies to the determination of tellurium copper content. Measuring range: 0. 0004% to 0. 0060%

YS/T 227.6-2010: Methods for chemical analysis of tellurium. Part 6: Determination of copper content. Solid-liquid separate-flame atomic absorption spectrophotometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of tellurium.Part 6. Determination of copper content.Solid-liquid separate-flame atomic absorption spectrophotometry ICS 77.120.99 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 227.6-1994 Methods for chemical analysis of tellurium Part 6. Determination of copper content Solid-liquid separation - Flame Atomic Absorption Spectrometry Part 6. Determinationofcoppercontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 227 "tellurium chemical analysis methods," a total of 12 parts. --- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry; --- Part 3. Determination of lead content by flame atomic absorption spectrometry; --- Part 4. Determination of iron content - Phenanthroline spectrophotometric method; --- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry; --- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry; --- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry; --- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry; --- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method; --- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method; --- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry. Part is divided into 6 sections. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of YS/T 227.6-1994 "determination of tellurium in copper content (Neocuproine - chloroform extraction photometric method)." versus YS/T 227.6-1994 compared, this section has the following changes. --- Changed the measurement method, the use of solid-liquid separation - flame atomic absorption spectrometry; --- Complements the precision, quality assurance and control provisions; --- Complements the "test report" requirement. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd. Participated in the drafting of this section. Beijing Mining Research Institute, Sichuan Apollo Solar Energy Technology Co., Ltd. The main drafters of this section. Ye Shiyuan, Zong Pu, Yu Li, Yan Ge. This part of the standard replaces the previous editions are. --- YS/T 227.6-1994; --- GB/T 2142-1980. Methods for chemical analysis of tellurium Part 6. Determination of copper content Solid-liquid separation - Flame Atomic Absorption Spectrometry Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

This section YS/T 227 specifies the method for determination of tellurium copper content. This section applies to the determination of copper content in tellurium. Measurement range. 0.0004% to 0.0060%.

2 principle of the method

Sample dissolved in nitric acid, dilute nitric acid leaching of copper ions and most of the matrix isolation, air - atomic absorption spectrometer wave acetylene flame Long 324.8nm at measuring the absorbance of copper, the standard curve method to calculate the amount of copper.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. Nitrate 3.1 (ρ1.42g/mL). 3.2 nitric acid (11). 3.3 nitric acid (199). 3.4 copper standard stock solution. Weigh 1.0000g copper (≥99.95%), placed in 200mL beaker, add 15mL of nitric acid (3.2), low-temperature heating to dissolve completely removing nitrogen oxides boil, cooled and transferred to 1000mL volumetric flask, 20mL of nitric acid was added (3.2), dilute to the mark and mix. 1mL solution containing 1mg of copper. 3.5 Copper standard solution. Weigh 5.00mL copper standard stock solution (3.4) in 100mL flask, add 2mL nitric acid (3.2), with Dilute with water to volume, and mix. This solution 1mL containing 50μg copper.

4 Instrument

Atomic absorption spectrometer, with copper hollow cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. In line with the measurement of the sample solution matrix solution features copper concentration should be less than 0.025μg/mL; --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%; With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum 0.5% concentration of the standard average absorbance; --- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.8.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 227.6-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 227.6-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 227.6-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 227.6-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 227.6-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 227.6-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.