HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YS/T 227.10-2010 English PDF

US$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 227.10-2010: Methods for chemical analysis of tellurium. Part 10: Determination of arsenic content. Hedride generation-atomic fluorescence spectrometry
Status: Valid

YS/T 227.10: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 227.10-2010English159 Add to Cart 3 days [Need to translate] Methods for chemical analysis of tellurium. Part 10: Determination of arsenic content. Hedride generation-atomic fluorescence spectrometry Valid YS/T 227.10-2010
YS/T 227.10-1994English199 Add to Cart 2 days [Need to translate] Determination of arsenic content in tellurium-n-butyl alcohol extraction arsenic-molybdenum blue photometric method Obsolete YS/T 227.10-1994

PDF similar to YS/T 227.10-2010


Standard similar to YS/T 227.10-2010

GB/T 3884.2   GB/T 3884.1   YS/T 252.1   YS/T 227.12   YS/T 227.2   YS/T 227.1   

Basic data

Standard ID YS/T 227.10-2010 (YS/T227.10-2010)
Description (Translated English) Methods for chemical analysis of tellurium. Part 10: Determination of arsenic content. Hedride generation-atomic fluorescence spectrometry
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H13
Classification of International Standard 77.120.99
Word Count Estimation 6,643
Date of Issue 2010-11-22
Date of Implementation 2011-03-01
Older Standard (superseded by this standard) YS/T 227.10-1994
Regulation (derived from) MIIT (2010) No. 126
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the tellurium determination of arsenic. This standard applies to the determination of arsenic Tellurium. Measuring range: 0. 0002% to 0. 0010%

YS/T 227.10-2010: Methods for chemical analysis of tellurium. Part 10: Determination of arsenic content. Hedride generation-atomic fluorescence spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of tellurium.Part 10. Determination of arsenic content.Hedride generation-atomic fluorescence spectrometry ICS 77.120.99 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 227.10-1994 Methods for chemical analysis of tellurium Part 10. Determination of arsenic content Hydride Generation - Atomic Fluorescence Spectrometry Part 10. Determinationofarseniccontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 227 "tellurium chemical analysis methods," a total of 12 parts. --- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry; --- Part 3. Determination of lead content by flame atomic absorption spectrometry; --- Part 4. Determination of iron content - Phenanthroline spectrophotometric method; --- Part 5. determination of selenium content of 2,3-diaminonaphthalene absorptiometry; --- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry; --- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry; --- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry; --- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method; --- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method; --- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry. This section section 10. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of YS/T 227.10-1994 "determination of tellurium in the amount of arsenic (n-amyl alcohol extracted arsenic molybdenum blue photometric method)." versus YS/T 227.10-1994 compared, this section has the following changes. --- Changed the measurement method using hydride generation - atomic fluorescence spectrometry; --- Complements the precision, quality assurance and control provisions; --- Complements the "test report" requirement. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd. Participated in the drafting of this section. Beijing Mining Research Institute, Liaoning Entry Inspection and Quarantine Bureau. The main drafters of this section. Science Wang, Cai, Yuan Yuxia, Dian Chen Geng, Wanghao Ying, Li Yan, Dong Xiuwen. This part of the standard replaces the previous editions are. --- YS/T 227.10-1994; --- GB/T 2146-1980. Methods for chemical analysis of tellurium Part 10. Determination of arsenic content Hydride Generation - Atomic Fluorescence Spectrometry Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

YS/T 227 provisions of this part of the determination of tellurium arsenic content. This section applies to the determination of tellurium arsenic content. Measurement range. 0.0002% to 0.0010%.

2 principle of the method

Conditions of use at a pH of 5.5 to 6.5, hydrolysis tellurium precipitated remove the bulk of the matrix, in hydrochloric acid medium, using a hydride - Original Sub fluorescence spectrometer determination of arsenic content.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 high-purity tellurium (mass fraction ≥99.999%). 3.2 nitrate (ρ1.42g/mL), pure class distinctions. 3.3 hydrochloric acid (ρ1.19g/mL), pure class distinctions. 3.4 nitric acid (11). 3.5 hydrochloride (11). 3.6 hydrochloride (19). 3.7 hydrochloric acid (595). 3.8 potassium hydroxide solution (200g/L). Weigh 40g of potassium hydroxide dissolved in 200mL of water stored in a plastic bottle, using now. 3.9 solution of potassium borohydride (20g/L). Weigh 10g of potassium borohydride were dissolved in 500mL of potassium hydroxide solution (5g/L), and now with the existing. 3.10 thiourea - ascorbic acid solution. Weigh thiourea in 300mL beaker, each 25g of ascorbic acid dissolved in water, the volume to 500mL volumetric flask, using now. 3.11 Storage arsenic standard solution. Accurately weigh 0.1320g trioxide (≥99.95%, pre-drying in a sulfuric acid desiccator to 24h A) in the 300mL beaker, add 20mL of potassium hydroxide solution (3.8), completely dissolved by heating with hydrochloric acid (3.3) and to slightly cold However, moved into 1000mL volumetric flask, dilute to volume, and mix. This solution 1mL containing 0.1mg arsenic. 3.12 arsenic standard solution. Pipette 5.00mL accurately arsenic standard stock solution (3.11) in 500mL volumetric flask, was added 75mL of hydrochloric acid (3.3), dilute to the mark and mix. This solution 1mL containing 1μg of arsenic. 3.13 bromocresol purple - bromothymol blue mixed indicator. Weigh 0.01g bromocresol purple and bromothymol blue dissolved in 100mL Water.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 227.10-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 227.10-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 227.10-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 227.10-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 227.10-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 227.10-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.