US$169.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 226.5-2009: Methods for chemical analysis of selenium. Part 5: Determination of silicon content. Molybdenum blue spectrophotometry method Status: Valid YS/T 226.5: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 226.5-2009 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of selenium. Part 5: Determination of silicon content. Molybdenum blue spectrophotometry method
| Valid |
YS/T 226.5-2009
|
YS/T 226.5-1994 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Determination of mercury content in selenium
| Obsolete |
YS/T 226.5-1994
|
PDF similar to YS/T 226.5-2009
Basic data Standard ID | YS/T 226.5-2009 (YS/T226.5-2009) | Description (Translated English) | Methods for chemical analysis of selenium. Part 5: Determination of silicon content. Molybdenum blue spectrophotometry method | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H17 | Classification of International Standard | 77.120.99 | Word Count Estimation | 6,658 | Date of Issue | 2009-12-04 | Date of Implementation | 2010-06-01 | Older Standard (superseded by this standard) | YS/T 226.7-1994 | Regulation (derived from) | MIIT [2009] No. 66 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the amount of selenium in the determination of silicon. This standard applies to the determination of selenium in silicon content. Measuring range: 0. 0002% 0. 0020% or. |
YS/T 226.5-2009: Methods for chemical analysis of selenium. Part 5: Determination of silicon content. Molybdenum blue spectrophotometry method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of selenium.Part 5. Determination of silicon content.Molybdenum blue spectrophotometry method
ICS 77.120.99
H17
People's Republic of China Nonferrous Metals Industry Standard
Replacing YS/T 226.7-1994
Chemical analysis of selenium
Part 5. Determination of the amount of silicon silicon molybdenum blue spectrophotometry
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 226 "selenium chemical analysis method" is divided into 13 parts.
--- Part 1. Determination of bismuth content - Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 2. Determination of antimony content Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 3. Determination of aluminum content Chromazurol S- cetylpyridinium bromide spectrophotometric method
--- Part 4. Determination of mercury content of dithizone - CTC colorimetric titration
--- Part 5. Determination of the amount of silicon silicon molybdenum blue spectrophotometry
--- Part 6. Determination of sulfur content symmetrical diphenyl semicarbazide spectrophotometry
--- Part 7. Determination of magnesium content - Flame atomic absorption spectrometry
--- Part 8. Determination of copper content - Flame atomic absorption spectrometry
--- Part 9. Determination of iron content by flame atomic absorption spectrometry
--- Part 10. Determination of nickel content by flame atomic absorption spectrometry
--- Part 11. Determination of lead content by flame atomic absorption spectrometry
--- Part 12. Determination of the amount of selenium sodium thiosulfate volumetric method
--- Part 13. silver, aluminum, arsenic, boron, mercury, bismuth, copper, cadmium, iron, gallium, indium, magnesium, nickel, lead, silicon, antimony, tin, tellurium, titanium, zinc contents
Inductively Coupled Plasma Mass Spectrometry
This section YS/T Part 5 226.
The partial replacement of YS/T 226.7-1994 "selenium determination of silicon content of silicon molybdenum blue spectrophotometric method." And YS/T 226.7-1994
Compared to the main section has the following changes.
--- Supplementary terms of quality assurance and control;
--- Increase the repeatability limit, will be allowed to poor reproducibility limit.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This section is responsible for drafting unit. Jinchuan Group Limited.
This section is drafted. Beijing Nonferrous Metal Research Institute.
Participated in the drafting of this section. Jinchuan Group Co., Ltd., Guangzhou Nonferrous Metal Research Institute.
The main drafters of this section. Liu Ying, Liu Hong, Gao Yan, Dong Liping, high Cheung Chak, Dai Fengying, Sun Hongying.
This part of the standard replaces the previous editions are.
--- GB 2116-1980;
--- YS/T 226.7-1994.
Chemical analysis of selenium
Part 5. Determination of the amount of silicon silicon molybdenum blue spectrophotometry
1 Scope
This section YS/T 226 specifies the method for determination of selenium in silicon content.
This section applies to the determination of selenium in silicon content. Measurement range. 0.0002% to 0.0020%.
2 Method summary
The sample is dissolved in nitric acid, selenium selenium dioxide formed volatiles were removed insoluble silica is added to make it into hydrofluoric acid soluble. Silicon and molybdic acid
Ammonium pH1.1 ~ pH1.5 generate heteropolyoxomolybdate extracted with n-amyl alcohol, organic phase hydrazine sulfate, tin dichloride reduced to silicon molybdenum blue, to wave
Length at 720nm measured absorbance.
Excess fluoride and boric acid to form a stable boron tetrafluoride anions does not interfere with the determination of silicon.
The presence of tartaric acid, 40μg arsenic, phosphorus and selenium do not interfere with the rest of the determination of silicon.
3 Reagents
The standard water is deionized water, conductivity is not more than 6.67 × 10-2μS · cm
-1.
Nitrate 3.1 (ρ1.42g/mL).
3.2 sulfate (ρ1.84g/mL).
3.3 nitric acid (1 + 1).
3.4 sulfate (1 + 1).
3.5 Hydrofluoric acid. hydrofluoric acid (excellent pure) platinum by distillation was purified by distillation or polytetrafluoroethylene sub-boiling distillation purified by distillation.
3.6 boric acid solution, especially pure, saturated solution.
3.7 ammonium molybdate solution (100g/L), high purity.
3.8 tartaric acid solution (100g/L), pure class distinctions.
3.9 stannous chloride solution (100g/L), washed with hydrochloric acid (1 + 1) are prepared (freshly prepared).
3.10 hydrazine sulfate solution (2.5g/L), with 0.25mol/L sulfuric acid formulation.
3.11 n-amyl alcohol, AR.
Silicon 3.12 Standard stock solution. Weigh 0.2142g silica (silica mass fraction of ≥99.99%) placed in a platinum crucible, add
5g of sodium carbonate into the mix, capped at 900 ℃ muffle furnace melting 1h, remove the cooled and transferred to a polyethylene cup, add cold water to dissolve, moved
1000mL volumetric flask, dilute with water to volume, and mix immediately moved polyethylene bottle. This solution 1mL containing 100μg silicon.
3.13 Silicon standard solution. Pipette 50.0mL silicon standard stock solution (3.12) into 1000mL volumetric flask, dilute to the mark,
Mix immediately transferred to a polyethylene bottle. This solution 1mL containing 5μg silicon.
4 instruments and apparatus
4.1 Spectrophotometer.
4.2 The carrier gas sealed evaporator (Figure 1).
Step 5 Analysis
5.1 Sample
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 226.5-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 226.5-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 226.5-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 226.5-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 226.5-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 226.5-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|