YS/T 1033-2015_English: PDF (YST 1033-2015, YST1033-2015)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Related Standard | Status | PDF |
YS/T 1033-2015 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Determination of element contents in dry barrier - X-ray fluorescence spectrometric method
|
YS/T 1033-2015
| |
YS/T 1033-2015
|
Standard ID | YS/T 1033-2015 (YS/T1033-2015) | Description (Translated English) | Determination of element contents in dry barrier. X-ray fluorescence spectrometric method | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H30 | Classification of International Standard | 77.120.10 | Word Count Estimation | 8,862 | Date of Issue | 2015-04-30 | Date of Implementation | 2015-10-01 | Drafting Organization | Aluminum Research Institute of China, Zhengzhou Institute of Nonferrous Metals Technology and Economy Research Institute of China Aluminum Corporation | Administrative Organization | National Non-Ferrous Metals Standardization Technical Committee (SAC/TC 243) | Regulation (derived from) | Ministry of Industry and Information Technology Announcement (2015 No. 28) | Proposing organization | National Non-Ferrous Metals Standardization Technical Committee (SAC/TC 243) | Issuing agency(ies) | Ministry of Industry and Information Technology of the People's Republic of China | Summary | This Standard specifies the method for determination of aluminum electrolytic with a dry impermeable feed nutrient contents. This Standard applies to the dry compound for aluminum electrolysis aluminum, silicon, iron, titanium, potassium, sodium, calcium and magnesium determination seepage. |
YS/T 1033-2015
(Determination of dry impermeable material elements in the X-ray fluorescence spectrometry)
ICS 77.120.10
H30
People's Republic of China Nonferrous Metals Industry Standard
Determination of dry impermeable material element content
X-ray fluorescence spectrometry
Issued on. 2015-04-30
2015-10-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) and focal points.
This standard is drafted by. Aluminum Corporation of China Zhengzhou Research Institute, Technical and Economic Research Institute of Nonferrous Metals.
Participated in the drafting of this standard. Aluminum Corporation of China Shandong Branch, Henan Branch of Aluminum Corporation of China, within
Meng Guhuo coal Hongjunlvdian limited liability company.
The main drafters. Zhang Aifen, Mahui Xia, white skies, Liu Jing, Yun-Xia Wang, Cong Mei, Ai Zhen, Wang Xiaowen, Li Zhihui, including Fang Fang.
Determination of dry impermeable material element content
X-ray fluorescence spectrometry
1 Scope
This standard specifies the method for determination of aluminum electrolytic with a dry impermeable feed nutrient contents.
This standard applies to aluminum electrolysis dry impermeable compound of aluminum, silicon, iron, titanium, potassium, sodium, calcium and magnesium (oxides expressed as Al2O3, SiO2,
Fe2O3, TiO2, K2O, Na2O, CaO, MgO) measurement. Determination of the range in Table 1.
Table 1
Component content range /% range component content /%
Al2O3 10.00 ~ 50.00 SiO2 10.00 ~ 60.00
Fe2O3 0.010 ~ 10.00 TiO2 0.010 ~ 5.00
K2O 0.010 ~ 5.00 Na2O 0.010 ~ 5.00
CaO 0.010 ~ 5.00 MgO 0.010 ~ 5.00
2 principle of the method
Sample was mixed with molten flux anhydrous lithium tetraborate and lithium metaborate to eliminate mineralogical effects and particle effects, and cast for X-ray
Fluorescence spectrometer to measure the shape of the glass, glass measuring X-ray fluorescence intensity in the measured elements. According to the calibration curve or equation to points
Analysis, calibration equation established with reference materials and inter-element interference effect correction. Matrix effect theoretical α coefficient or fundamental parameter method
Absorption correction between elements - enhancing effect.
Note. Due to the versatility of molten glass technology allows the use of a variety of flux and calibration mode. But it should meet certain reproducibility, sensitivity, and accuracy. If the
A laboratory own method complies with the terms of, you can considered to meet this standard.
3 Reagents
3.1 anhydrous lithium tetraborate and lithium metaborate mixed flux [Li2B4O7 (12) LiBO2 (22)], the flux contains a certain amount of water, the following should be adopted
One of two methods to compensate.
a) burning 2h at 700 ℃, cooling backup in the dryer;
B) When the flux per kg sufficiently mixed Take two parts, a predetermined melting temperature of the molten 10min, another predetermined melt
Room melted, take the loss on ignition greater flux correction amount, according to equation (1) to calculate a correction factor. Flux should be sealed. Weekly or every
Determination of loss on ignition kg once.
F =
100-L
(1)
Where.
F --- the correction factor;
L --- Loss on ignition, expressed as a percentage.
3.2 the ammonium nitrate solution. 500g/L.
|