HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Aug 2025)

YS/T 1001-2014 English PDF

US$289.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 1001-2014: Method of ultrasonic inspection for sheet titanium and titanium alloy
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 1001-2014English289 Add to Cart 3 days [Need to translate] Method of ultrasonic inspection for sheet titanium and titanium alloy Valid YS/T 1001-2014

PDF similar to YS/T 1001-2014


Basic data

Standard ID YS/T 1001-2014 (YS/T1001-2014)
Description (Translated English) Method of ultrasonic inspection for sheet titanium and titanium alloy
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H64
Classification of International Standard 77.120.50
Word Count Estimation 11,182
Date of Issue 10/14/2014
Date of Implementation 4/1/2015
Quoted Standard JB/T 10061
Regulation (derived from) People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180)
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This Standard specifies the method for ultrasonic testing of titanium and titanium alloy sheet. Including the principle of the method, the general requirements, testing equipment, the test block, detection mode selection, testing, evaluation and inspectio

Standard similar to YS/T 1001-2014

GB/T 2524   GB/T 3620.1   YS/T 968   YS/T 1684   YS/T 1683   YS/T 1592   

YS/T 1001-2014: Method of ultrasonic inspection for sheet titanium and titanium alloy

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method of ultrasonic inspection for sheet titanium and titanium alloy ICS 77.120.50 H64 People's Republic of China Nonferrous Metals Industry Standard Titanium and titanium alloy sheets ultrasonic detection method Issued on. 2014-10-14 2015-04-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized. This standard was drafted. Baoji Titanium Group Limited, Western Metal Materials Co., Ltd., Baosteel Special Steel Co., Ltd., Baoji Titanium shares Limited copies. The main drafters of this standard. Ma Xiaohuai, Guo Yongqing, Fengjun Ning, Xintian Ning, Ma Zhongxian, Hu Zhijie, Zhang Yansheng, Lixian Jun, Yang Jun red, Zhang Jie frequency. Titanium and titanium alloy sheets ultrasonic detection method

1 Scope

This standard specifies the method for ultrasonic inspection of titanium and titanium alloy sheet. Including the principle of the method, general requirements, testing equipment, contrast Select the test block detection mode, the detection, evaluation and inspection records and reports. This standard applies to Lamb wave method using a thickness of 0.3mm ~ 6mm titanium and titanium alloy sheet of ultrasonic testing.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. JB/T 10061 A-mode pulse reflection type ultrasonic detector General technical conditions

3 PRINCIPLE OF THE METHOD

Lamb waves in the structure having two parallel surfaces of one by the shear and compression coupling from each other, and spread over the entire thickness Stress wave. Mainly used to detect titanium and titanium alloy sheet internal stratification, cracks and other defects, and other exposed or not exposed to the surface of the tissue Discontinuities.

4 General requirements

4.1 Operating personnel engaged in titanium and titanium alloy thin ultrasonic inspection should meet ministerial or equivalent level Ⅰ learn and above NDT Measuring the level of qualification, the issue of inspection reports and explanations should reach the ministerial or equivalent level and above grade Ⅱ learn NDT personnel Qualification levels. 4.2 ultrasonic examination should be carried out in titanium and titanium alloy sheet finished state. By all round the subject sheet metal shear surface should be neat uniform, flat surface, There should be no case affect the test results of oil droplets, pits, corrosion.

5 Testing Equipment

5.1 Detector Lamb wave testing instruments used should have a sufficiently high transmit power and a wide transmit pulse width. For the A-mode pulse reflection Ultrasonic detector should meet the JB/T 10061 requirements. 5.2 Probe 5.2.1 fixed angle or variable angle probe probe, wafer size 20mm × 30mm or 30mm × 40mm, the wafer may be used Area not less than 600mm2 other Lamb wave probe. Probe frequency should be within the range of 1.25MHz ~ 5MHz, frequency and its standard He said frequency shall not exceed the difference between the nominal frequency ± 10%. 5.2.2 The probe should be smaller frontier blind, blind test plate end face is generally not more than 50mm.
......
YS/T 1001-2014