HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

SN/T 4119-2015 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 4119-2015: Determination of boron content in glass and glass products. Inductively coupled plasma-atomic emission spectrometric method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 4119-2015English189 Add to Cart 3 days [Need to translate] Determination of boron content in glass and glass products. Inductively coupled plasma-atomic emission spectrometric method Valid SN/T 4119-2015

PDF similar to SN/T 4119-2015


Standard similar to SN/T 4119-2015

GB/T 40913   GB 4544   QB/T 3729   SN/T 4027   SN/T 4028   SN/T 4026   

Basic data

Standard ID SN/T 4119-2015 (SN/T4119-2015)
Description (Translated English) Determination of boron content in glass and glass products. Inductively coupled plasma-atomic emission spectrometric method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard Y22
Classification of International Standard 81.040.30
Word Count Estimation 8,819
Date of Issue 2015-02-09
Date of Implementation 2015-09-01
Quoted Standard GB/T 602; GB/T 1549; GB/T 6682
Regulation (derived from) State-Quality-Inspection-Accreditation [2015] 59
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the glass and glass products boron content by inductively coupled plasma atomic emission spectrometry (ICP-AES) Determination. This standard applies to the determination of glass and glass products of boron. Measurement range: 0.001% to 3.0%.

SN/T 4119-2015: Determination of boron content in glass and glass products. Inductively coupled plasma-atomic emission spectrometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Glass and glass products boron content - Inductively coupled plasma atomic emission spectrometry) People's Republic of China Entry-Exit Inspection and Quarantine Standards Inductively coupled glass of boron and its products Plasma Atomic Emission Spectrometry Issued on. 2015-02-09 2015-09-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Guangdong CIQ. The main drafters of this standard. Xiaoda Hui, Zhao Quan, Lee Jun, Tang Kun, Huang Jinyu, Lin Chunmei, ZHOU Ming-hui, Zheng Jianguo. Inductively coupled glass of boron and its products Plasma Atomic Emission Spectrometry

1 Scope

This standard specifies the glass and glass products boron content by inductively coupled plasma atomic emission spectrometry (ICP-AES) Determination. This standard applies to the determination of glass and glass products of boron. Measurement range. 0.001% to 3.0%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents GB/T 1549 Methods for chemical analysis of fiber glass Laboratory use specifications and test methods GB/T 6682 Analysis Principle 3 Glass and its products even after grinding, 40% sodium hydroxide solution, after dissolution in microwave digestion, acidification of the test solution, After constant volume, using ICP-AES test the content of boron.

4 Reagents and materials

Unless otherwise specified, use the gifted class pure reagents, test water should meet the two water GB/T 6682 regulations. 4.1 sodium hydroxide. 4.2 HCl. 36% ~ 38%. 4.3 boron standard stock solution at a concentration of 100μg/mL. 4.4 sodium hydroxide solution (40%) Weigh sodium hydroxide (4.1) 40.0g, was added 80mL of water to dissolve, set the volume at 100mL plastic flask. 4.5 filter. 0.45μm, nylon. 4.6 standard test sieve. aperture of 80μm.

5 instruments and equipment

5.1 blast oven. 5.2 Electronic balance. a sense of the amount of 0.1mg. 5.3 temperature-controlled heating plate. 5.4 microwave digestion. 5.5 Inductively coupled plasma atomic emission spectroscopy (ICP-AES).

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 4119-2015_English be delivered?

Answer: Upon your order, we will start to translate SN/T 4119-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 4119-2015_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 4119-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.