US$209.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 3343-2012: Determination of manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum, and titanium in Stainless steel. Inductively coupled plasma atomic emission spectrometry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 3343-2012 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Determination of manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum, and titanium in Stainless steel. Inductively coupled plasma atomic emission spectrometry
| Valid |
SN/T 3343-2012
|
Standard similar to SN/T 3343-2012 SN/T 5268
Basic data | Standard ID | SN/T 3343-2012 (SN/T3343-2012) | | Description (Translated English) | Determination of manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum, and titanium in Stainless steel. Inductively coupled plasma atomic emission spectrometry | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Word Count Estimation | 8,831 | | Quoted Standard | GB/T 602; GB/T 6682; GB/T 20066 | | Regulation (derived from) | National Quality Inspection (2012) 777; industry standard filing Notice 2013 No. 4 (No. 160 overall) | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the stainless steel manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum and titanium elements by inductively coupled plasma atomic emission spectrometry method. This standard applies to the carbon content of not mo |
SN/T 3343-2012: Determination of manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum, and titanium in Stainless steel. Inductively coupled plasma atomic emission spectrometry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum, and titanium in Stainless steel.Inductively coupled plasma atomic emission spectrometry
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Stainless steel, manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum and titanium
Inductively coupled plasma atomic content
Emission Spectrometry
Determinationofmanganese, phosphorus, silicon, chromium, nickel,
copper, molybdenum, andtitaniuminStainlesssteel-
Issued on. 2012-12-12
2013-07-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Jiangsu Entry-Exit Inspection and Quarantine Bureau.
The main drafters of this standard. a new kingdom, Xu Yuyu, Wang Hui, Liu Feng, Wu Guangyu, Zhu Jiayu.
Stainless steel, manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum and titanium
Inductively coupled plasma atomic content
Emission Spectrometry
1 Scope
This standard specifies the inductively coupled plasma atomic stainless steel manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum and titanium emission spectrometer
method.
This standard applies to the determination of carbon content of not more than 0.20% of the stainless steel manganese, phosphorus, silicon, chromium, nickel, copper, molybdenum and titanium content. Measurement
Table 1 given range.
The silicon standard assay for soluble silicon.
Table 1 Determination of elements content range
element
Content range (mass fraction)
element
Content range (mass fraction)
Mn 0.01 ~ 10
P 0.003 ~ 0.25
Si 0.01 ~ 2
Cr 0.02 ~ 30
Ni 0.01 ~ 30
Cu 0.01 ~ 5
Mo 0.01 ~ 5
Ti 0.01 ~ 1
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents
GB/T 6682 analytical laboratory use specifications and test methods
GB/T 20066 Steel and iron - Sampling and determination of the chemical composition of the sample with a sample preparation method
3 Method summary
Samples with hydrochloric acid - nitric acid mixture dissolved, yttrium internal standard element After cooling, diluted to determine the volume of the sample solution is introduced into the plasma
Atomic emission spectrometer to measure the wavelength corresponding elements in its emission intensity, measured by elemental analysis to calculate emission intensity line and the internal standard line emission intensity
The ratio of the degree, according to the standard curve to determine the amount of analyte.
4 Reagents and materials
Unless otherwise indicated in the analysis using only recognized as analytical reagents and GB/T 6682 provisions of secondary water.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 3343-2012_English be delivered?Answer: Upon your order, we will start to translate SN/T 3343-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 3343-2012_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3343-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|