SN/T 2199-2008: Food contact materials. Plastics. Test methods for overall migration into aqueous food simulants. By article filling
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2199-2008English174 Add to Cart 3 days [Need to translate] Food contact materials. Plastics. Test methods for overall migration into aqueous food simulants. By article filling Valid SN/T 2199-2008

PDF similar to SN/T 2199-2008


Standard similar to SN/T 2199-2008

QB/T 5077   QB/T 5076   QB/T 2358   SN/T 4132   SN/T 2198   

Basic data

Standard ID SN/T 2199-2008 (SN/T2199-2008)
Description (Translated English) Food contact materials. Plastics. Test methods for overall migration into aqueous food simulants. By article filling
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard Y28
Word Count Estimation 9,947
Date of Issue 2008-11-18
Date of Implementation 2009-06-01
Quoted Standard GB/T 12808; EN 1186-1-2002
Adopted Standard BS EN 1186-9-2002, IDT
Regulation (derived from) National Quality Inspection [2008] No. 577
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the test in the limited time and temperature through the plastic container filled with the selected aqueous food simulants, measured plastic container in direct contact with aqueous food simulants surface migration capacity. This standard applies to be filled plastic products.

SN/T 2199-2008: Food contact materials. Plastics. Test methods for overall migration into aqueous food simulants. By article filling


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Food contact materials.Plastics.Test methods for overall migration into aqueous food simulants.By article filling Exit inspection and quarantine industry standard book People's Republic of China Plastic food contact materials Watery overall migration food simulants Test Method Filling method Posted 2008-11-18 2009-06-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard is equivalent to using BSEN1186-9.2002 "overall migration and food contact materials and articles plastic water food simulants Amount of test methods for filling Law ", the technical requirements of this standard is exactly the same BSEN1186-9.2002 standards. This standard is in accordance with GB/T 1.1-2000. Requirements "Standardization Guide Part 1 standard structure and write rules," the root According BSEN1186-9.2002 redrafted written. The main modifications are. --- Because regardless of the technical content of this standard, the preamble of the original text deleted; --- Chapter 2, according to GB/T 1.1-2000 requirements to prepare normative references; --- 5.6 evaporating dish to remove metals, ceramics and other glass evaporating dish to retain only evaporating dish. Appendix A of this standard is an informative annex. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted by the People's Republic of China Liaoning Entry Inspection and Quarantine Bureau. The main drafters of this standard. Zhaoxue Rong, Xu Wei, in a vast, Chen Wei. This standard is the first release of the entry-exit inspection and quarantine industry standards. Plastic food contact materials Watery overall migration food simulants Test Method Filling method

1 Scope

This standard specifies under defined test time and temperature, through the plastic container filled with the selected aqueous food simulants, Measurement and Plastic containers aqueous food simulants in direct contact with the surface of the total migration. This standard applies to be filled plastics.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. Where dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard. After the increase, if any change, then, only those marked increase rewritten into Prospective new version applies to this standard, for no dated references, should be using the latest version. GB/T 12808 standard laboratory glassware single line pipette (GB/T 12808-1991, eqv648. 1977) EN1186-1.2002 plastic food contact materials Part I. Selection Guide for total migration test conditions and methods Principle 3 3.1 plastic sample overall migration refers to the non-volatile substance is filled into a sample food simulant is evaporated by the remaining non-volatile residue Quality slag. Select 3.2 Test conditions and food simulant see EN1186-1.2002 in Chapter 4 to Chapter 6. 3.3 Under the conditions of no more than 70 ℃, water food simulants filled into the sample, and maintain a certain period of time. Until a predetermined time, Poured from the sample food simulants, each sample was evaporated in food simulants, measured non-volatile residue quality, and in milligrams per square Decimeter sample surface area in contact with food simulation was to indicate that the mg/dm2 representation. NOTE. In some cases the test temperature can exceed 70 ℃.

4 Reagents and materials

Reagent preparation and purity see EN1186-1.2002 in Chapter 5. 4.1 simulant A. distilled water or water homogeneity. 4.2 mimetic B. an aqueous solution of acetic acid 30g/L. 4.3 mimetic C. aqueous ethanol (9 + 1). 4.4 Alcohol mimetic. alcohol content more than 10% (volume fraction) of liquid or beverage. Note. For alcohol exceeds 10% (volume fraction) of liquid and drink direct contact with the plastic material, tests shall be quite alcohol concentration of the aqueous solution get on. 5. Apparatus 5.1 Analytical balance. accuracy 0.1mg. 5.2 lint-free cloth or soft brush. 5.3 beaker, 2L. 5.4 glass beads, diameter 2mm ~ 3mm.