HOME   Cart(1)   Quotation   About-Us Tax PDFs Standard-List
Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 189759 (17 Sep 2023)

SN/T 1902-2007 (SNT1902-2007)

SN/T 1902-2007_English: PDF (SNT 1902-2007, SNT1902-2007)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Related StandardStatusPDF
SN/T 1902-2007English419 Add to Cart 3 days [Need to translate] Determination of imidacloprid and acetamiprid residues in fruits and vegetables. HPLC SN/T 1902-2007 Valid SN/T 1902-2007

BASIC DATA
Standard ID SN/T 1902-2007 (SN/T1902-2007)
Description (Translated English) Determination of imidacloprid and acetamiprid residues in fruits and vegetables. HPLC
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard C53
Classification of International Standard 07.100.30
Word Count Estimation 13,187
Date of Issue 2007-05-23
Date of Implementation 2007-12-01
Drafting Organization Jiangsu Entry-Exit Inspection and Quarantine of the PRC
Administrative Organization National Certification and Accreditation Administration Committee
Regulation (derived from) National-accreditation-Science [2011] 63
Summary This standard specifies the fruits and vegetables imidacloprid, Acetamiprid residues HPLC method. This standard applies to tomatoes, cucumbers, citrus imidacloprid, Acetamiprid residue test.

SN/T 1902-2007
Determination of imidacloprid and acetamiprid residues in fruits and vegetables.HPLC
Exit inspection and quarantine industry standard book People's Republic of China
Determination of imidacloprid, Acetamiprid Residues in Fruits and Vegetables
High Performance Liquid Chromatography
Posted 2007-05-23
2007-12-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
Appendix A of this standard is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard by the People's Republic of China Jiangsu CIQ is responsible for drafting.
The main drafters of this standard. He Songtao, Yu Ye, B Xiaojuan, Zhang Aidong, Liu Yijun, Sun Jiangang.
This is the first issue of inspection and quarantine industry standards.
Determination of imidacloprid, Acetamiprid Residues in Fruits and Vegetables
High Performance Liquid Chromatography
1 Scope
This standard specifies the fruits and vegetables of Imidacloprid, high performance liquid chromatographic method acetamiprid residues.
This standard applies to tomatoes, cucumbers, citrus imidacloprid, acetamiprid residues test.
2 Determination
2.1 Sample Preparation
Samples will be taken from the original shrink separated 1kg, take the edible parts, crushed by the organization are divided into two, loaded into a clean container, as a sample,
Sealed and marked with tags.
2.2 Sample preservation
The sample was stored frozen at -18 ℃ below.
NOTE. In the sample preparation process, should prevent sample contamination or the occurrence of the change of residue content.
2.3 Method summary
Sample residual imidacloprid, acetamiprid extracted with acetonitrile extract was Florey silica column purification, concentrated, constant volume, use with UV detection
High performance liquid chromatograph detector or diode array detector.
2.4 Reagents and materials
Unless otherwise specified, the reagents were of analytical grade, water is distilled or deionized water.
2.4.1 acetonitrile. HPLC grade.
2.4.2 n-hexane.
2.4.3 acetone.
2.4.4 Sodium chloride. 140 ℃ baking 4h.
2.4.5 imidacloprid Standard. 96% or greater purity.
2.4.6 acetamiprid Standard. 96% or greater purity.
2.4.7 imidacloprid, acetamiprid standard solution. Accurately weigh an adequate amount of imidacloprid, acetamiprid standard, with acetonitrile formulated to 100μg/mL of
Single stock standard solution, and then acetonitrile + water (30 + 70) diluted to a suitable concentration mixed standard working solution as needed.
2.4.8 SPE, Florey silicon column (Florisil), volume 3mL cartridges, filling 500mg.
2.5 Equipment
2.5.1 High performance liquid chromatograph. equipped with an ultraviolet detector or diode array detector.
2.5.2 oscillator.
2.5.3 Nitrogen blowing instrument.
2.5.4 rotary evaporator.
2.5.5 vortex mixer.
2.5.6 micro syringe. 100μL.
2.6 Determination of step
2.6.1 Extraction
Weigh 25g sample (accurate to 0.01g), placed in 250mL conical flask with stopper, accurate added 50.0mL of acetonitrile, placed 2h, vibration
After extraction 30min swing filtered through filter paper. The filtrate was collected containing 5g ~ 7g sodium chloride in 100mL stoppered measuring cylinder, stoppered, drama