US$289.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 0811-2012: Rules for the entry-exit inspeciton of power transformers, power supplies, reactors and similar products. General requirements Status: Valid SN/T 0811: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
SN/T 0811-2012 | English | 289 |
Add to Cart
|
3 days [Need to translate]
|
Rules for the entry-exit inspeciton of power transformers, power supplies, reactors and similar products. General requirements
| Valid |
SN/T 0811-2012
|
SN/T 0811.1-2005 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Inspection procedures for import and export of power transformers, power supply units and similar devices - Part 1: General requirements
| Obsolete |
SN/T 0811.1-2005
|
SN/T 0811-1999 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Rules for the inspection of household and similar purposes transformer for export
| Obsolete |
SN/T 0811-1999
|
SN/T 0811-1991 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Inspection of export of household and similar purposes transformer)
| Obsolete |
SN/T 0811-1991
|
PDF similar to SN/T 0811-2012
Standard similar to SN/T 0811-2012 GB 1094.1 GB 1094.11 SN/T 3248.2
Basic data Standard ID | SN/T 0811-2012 (SN/T0811-2012) | Description (Translated English) | Rules for the entry-exit inspeciton of power transformers, power supplies, reactors and similar products. General requirements | Sector / Industry | Commodity Inspection Standard (Recommended) | Classification of Chinese Standard | K41 | Word Count Estimation | 11,137 | Older Standard (superseded by this standard) | SN/T 0811.1-2005 | Quoted Standard | GB/T 2828.1; GB 17625.1; GB 17625.2; GB 19212.1-2008; SN/T 0002; SN/T 2838.2 | Regulation (derived from) | National Quality Inspection (2012) 643; industry standard filing Notice 2013 No. 1 (No. 157 overall) | Issuing agency(ies) | General Administration of Customs | Summary | This standard specifies the import and export of power transformers, power supplies, reactors and similar products. This standard specifies the following types of dry-type transformers, power (including switch-mode power supply) and reactors, and its wind |
SN/T 0811-2012: Rules for the entry-exit inspeciton of power transformers, power supplies, reactors and similar products. General requirements ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules for the entry-exit inspeciton of power transformers, power supplies, reactors and similar products.General requirements
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Instead of the SN/T 0811.1-2005
Import and export of power transformers, power supplies, reactors and similar
General requirements for product testing procedures
Rulesfortheentry-exitinspectionofpowertransformers, powersupplies,
Issued on. 2012-10-23
2013-05-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Instead of the standard SN/T 0811.1-2005 "the inspection of import and export power transformers, power supply units and similar devices - Part 1.
General requirements. "
This standard compared with SN/T 0811.1-2005, the main technical changes are as follows.
--- Standard name changed to "import and export of power transformers, power supplies, reactors and similar products inspection regulations General requirements";
--- Standard structure, chapter choreography, performed a number of changes;
It was modified --- standard range;
--- Increased SN/T 2838.2 description of the terms and definitions;
--- For inspection and supervision model test method and its contents has been modified;
--- Requirements for different test methods and test items corresponding test method was modified.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China, Shenzhen CIQ, Shenzhen Inspection and Quarantine Science Research Institute.
The main drafters of this standard. Li Jun, Liu Zehua, Yin Jie, Chen Lijun, Chen, Liu Min.
This standard replaces the standards previously issued as follows.
--- SN/T 0811.1-2005.
Introduction
"Import and export of power transformers, power supplies, reactors and similar products - General requirements for the inspection," the import and export of power transformers, power supplies,
Reactors and similar products based on the work of inspection, import and export of power transformers, power supplies, reactors and similar products play a guiding and regulating inspection
effect.
With China's accession to the World Trade Organization (WTO) and the "People's Republic of China Import and Export Commodity Inspection Law" and its implementing regulations amended
Import and Export Commodity Inspection, great changes occurred in work mode. In order to meet changes in the form, the state inspection and quarantine departments in charge of the establishment of a
Inspection and quarantine standards.
This standard belongs to the inspection and quarantine standards on the third floor --- categories of common standards, provides for import and export of power transformers, power supplies, reactors
And similar general requirements for product testing.
Import and export of power transformers, power supplies, reactors and similar
General requirements for product testing procedures
1 Scope
This standard specifies the import and export of power transformers, power supplies, reactors and similar products sampling, testing and judgment.
This standard covers the following types of dry-type transformers, power supply (including switch mode power supplies) and reactors, which may be encapsulated or non-winding
Encapsulation type.
Note 1. The difference between the transformers, power supply and switching power supply as follows.
--- Transformer without changing the frequency. However, the transformer (eg. constant voltage transformers) can have no more than 30kHz internal resonance frequency;
--- Power supply, internal operating frequency and the frequency and waveform waveform with different power supply and the internal operating frequency not exceeding 500Hz;
--- Of switched mode power supply, internal operating frequency and the frequency and waveform waveform with different power supply and the internal operating frequency exceeding 500Hz rather than
100MHz.
a) Stationary or portable, single-phase or multi-phase, air-cooled (self-cooled or air-cooled), with or supporting the use of independent, does not constitute a distribution network
Parts and security isolation transformer, which has the following characteristics.
1) rated supply voltage not exceeding AC 1000V;
2) does not exceed the rated frequency 500Hz;
And, except as otherwise provided in other parts of this standard, the meet the following requirements.
1) isolation transformers.
--- Single-phase transformer rated output not exceeding 25kVA, multi-phase transformers not exceeding 40kVA;
--- Load output voltage and rated output voltage exceeds 50V AC rather than AC 500V, or according to national wiring regulations
Or provisions for a special purpose, not more than AC 1000V.
2) safety isolating transformer.
--- Single-phase transformer rated output not exceeding 10kVA, multi-phase transformers not exceeding 16kVA;
--- Between the conductor and quality control or any of a protective earth conductor, no-load output voltage and rated output voltage does not exceed AC
50V.
Note 2. When the installation procedures or appliances (such as. electric toys, bells, portable power tools, portable lamps) specification requirements for the double or reinforced insulation between circuits
Insulation, to use an isolation transformer or a safety isolating transformer.
b) Stationary or portable, single-phase or multi-phase, air-cooled (self-cooled or air-cooled), with or supporting the use of independent, does not constitute a distribution network
Part of separating transformers, auto-transformers, voltage regulators and small reactors, which have the following features.
1) rated supply voltage not exceeding AC 1000V;
2) rated supply frequency not exceeding 500Hz;
And, except as otherwise provided in other parts of this standard, the values in line with the following provisions.
1) for both independent use and are supporting the use of transformers, no-load output voltage and rated output voltage not exceeding 15kV, for independent use
Transformers, AC rated output voltage is not less than 50V.
2) rated output does not exceed the following values.
--- Single-phase transformer, 1kVA;
--- Single-phase reactor, 2kVA;
--- Multiphase transformer, 5kVA;
--- Multiphase reactors, 10kVA.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 0811-2012_English be delivered?Answer: Upon your order, we will start to translate SN/T 0811-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 0811-2012_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 0811-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version SN/T 0811-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0811-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|