HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 0184.3-2008 English PDF

US$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 0184.3-2008: Determination of Listeria monocytogenes in food for import and export. Part 3: Immuno-magnetic beads assay
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 0184.3-2008English349 Add to Cart 3 days [Need to translate] Determination of Listeria monocytogenes in food for import and export. Part 3: Immuno-magnetic beads assay   SN/T 0184.3-2008

PDF similar to SN/T 0184.3-2008


Standard similar to SN/T 0184.3-2008

GB 1886.48   GB 2711   SN/T 1888.4   SN/T 0500   SN/T 0184.4   SN/T 0176   

Basic data

Standard ID SN/T 0184.3-2008 (SN/T0184.3-2008)
Description (Translated English) Determination of Listeria monocytogenes in food for import and export. Part 3: Immuno-magnetic beads assay
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard C53
Classification of International Standard 07.100.30
Word Count Estimation 10,171
Date of Issue 2008-09-04
Date of Implementation 2009-03-16
Quoted Standard GB 19489; SN/T 0184.1
Regulation (derived from) Industry standard filing Notice No. 11 of 2008
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the import and export food Listeria monocytogenes bacteria sampling, sample preparation and immunomagnetic detection methods. This standard applies to import and export food Listeria monocytogenes bacteria test.

SN/T 0184.3-2008: Determination of Listeria monocytogenes in food for import and export. Part 3: Immuno-magnetic beads assay


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of Listeria monocytogenes in food for import and export Part 3. Immuno-magnetic beads assay Exit inspection and quarantine industry standard book People's Republic of China Importers monocytogenes in foods Listeria detection methods Part 3. Immunization beads Posted 2008-09-04 2009-03-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This section of the Appendix A, Appendix B are normative appendix. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Liaoning Province Exit Inspection and Quarantine. The main drafters of this section. Wu Bin, Li Zhenrong, Huzhuan Wei, Wang Yuping, JIANG flag. The first part of the Department of Inspection and Quarantine issued by industry standards. Importers monocytogenes in foods Listeria detection methods Part 3. Immunization beads

1 Scope

SN/T 0184 provisions of this part of the import and export food monocytogenes Listeria sampling, sample preparation and IMB examination method. This section applies to imported and exported food monocytogenes Listeria test.

2 Normative references

The following documents contain provisions which, through reference SN/T 0184 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB 19489 General requirements for laboratory biosafety SN/T 0184.1 import and export food monocytogenes Listeria testing methods

3 Methods Summary

The diameter of 0.05μm ~ 4μm magnetic microbeads Surface Chemical, and combined with the Listeria specific antibody, prepared MACS, it can and Listeria in food antigen binding, so the detection of Listeria in food. The sample was 24h ~ 48h by After the bacteria were taken 1mL enrichment broth is added and 20μL MACS lidded plastic tube, mixing in magnetic plate background, if you have listeria Bacterial antigen is present, MACS will be captured, and the use of magnetic beads gather immune, chromogenic medium and inoculated into any after cleaning Choose one medium (OXA or PALCAM agar) for the selective separation plates typical Listeria colonies for confirmation, final Determine whether there monocytogenes Listeria through a series of tests.

4 equipment and appliances

4.1 Incubator. 37 ℃ ± 1 ℃; 41.5 ℃ ± 1 ℃. 4.2 Water bath. 45 ℃ ± 1 ℃. 4.3 Micropipettes. 20μL ~ 200μL, 10μL, 1mL. 4.4 Graduated pipettes. 5mL, 10mL. 4.5 Sterilization of glassware. cylinders, Erlenmeyer flasks, Petri dishes (diameter 90mm), test tubes. 4.6 sterile tube (Eppendorf tube). 1.5mL. 4.7 anti-Listeria immunity Beads. The beads can be obtained from commercial sources. It should be exactly in accordance with the manufacturer's instructions operating. 4.8 vortex mixer. 4.9 with a magnetic carrier in a magnetic separator.

5 medium and reagents

Unless otherwise specified, the reagents were of analytical grade, water is distilled water. 5.1 pancreatic casein soy broth (TSB-YE). See Section A. Chapter 1.