HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 0192-2017 English PDF

US$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 0192-2017: Determination of bromopropylate residue in fruits for export
Status: Valid

SN/T 0192: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 0192-2017English439 Add to Cart 4 days [Need to translate] Determination of bromopropylate residue in fruits for export Valid SN/T 0192-2017
SN 0192-1993English179 Add to Cart 2 days [Need to translate] Method for determination of bromopropylate residues in fruits for export Obsolete SN 0192-1993

PDF similar to SN/T 0192-2017


Standard similar to SN/T 0192-2017

NY/T 3252.1   NY/T 3082   SN/T 0803.6   SN/T 0652   SN/T 0151   SN/T 0190   

Basic data

Standard ID SN/T 0192-2017 (SN/T0192-2017)
Description (Translated English) Determination of bromopropylate residue in fruits for export
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard B31
Classification of International Standard 67.080
Word Count Estimation 19,159
Date of Issue 2017-05-12
Date of Implementation 2017-12-01
Older Standard (superseded by this standard) SN 0192-1993
Quoted Standard GB/T 6682
Regulation (derived from) State-Quality-Inspection-Accreditation (2017) 228
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the detection and confirmation methods for bromine ester residues in fruits. This standard applies to the detection and confirmation of bromo oxime residues in apple, cherry, lemon, grass carp, pineapple, grape and watermelon.

SN/T 0192-2017: Determination of bromopropylate residue in fruits for export

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of bromopropylate residue in fruits for export People's Republic of China entry and exit inspection and quarantine industry standards Replacing SN 0192-1993 Method for detecting residual bromo oxime ester in exported fruits Released on.2017-05-12 2017-12-01 implementation People's Republic The General Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces SN 0192-1993 "Test method for bromine ester residues in exported fruits". Compared with SN 0192-1993, in addition to editorial changes, the main technical changes are as follows. --- Increased sample matrix; --- Modified the sample extraction step; --- Modified the sample purification step; --- Change the sample determination packed column to a capillary column; --- Added gas chromatography mass spectrometry confirmation method; --- Sampling steps were omitted. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard is proposed and managed by the National Certification and Accreditation Administration. This standard was drafted. Shanghai Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Shi Yizhen, Yang Huiqin, Cheng Jia, Fan Yanli, Zhou Yao, Yi Xionghai, Deng Xiaojun, Zhu Jian. The previous versions of the standards replaced by this standard are. ---SN 0192-1993. Method for detecting residual bromo oxime ester in exported fruits

1 Scope

This standard specifies the detection and confirmation methods for bromine ester residues in fruits. This standard applies to the detection and confirmation of bromo oxime residues in apples, cherries, lemons, strawberries, pineapples, grapes and watermelons.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 6682 Analytical laboratory water specifications and test methods

3 method summary

The residual bromo oxime ester in the sample is extracted with acetonitrile, and after centrifugation and centrifugation, the supernatant is purified by a solid phase extraction column with electron capture detection. Gas chromatographic determination of the detector, external standard method quantification, if necessary, confirmed by gas chromatography-mass spectrometry.

4 reagent materials

The reagents used were of analytical grade unless otherwise stated. 4.1 Acetonitrile. Chromatographically pure. 4.2 Toluene. chromatographically pure. 4.3 n-hexane. chromatographically pure. 4.4 Sodium chloride. 4.5 anhydrous sodium sulfate. burned at 650 ° C for 4 h before use, cooled and stored in a desiccator. 4.6 Acetonitrile-toluene solution (3 1, volume ratio). Take.200 mL of toluene, add 600 mL of acetonitrile, shake and set aside. 4.7 Bromopropylate (C17H16Br2O3, CAS No. 8181-80-1) Standard. Purity greater than or equal to 98%. 4.8 Bromine oxime standard stock solution. Accurately weigh 0.01g (accurate to 0.0001g) bromo oxime standard in 10mL volumetric flask, use The n-hexane was dissolved to prepare a standard stock solution having a concentration of 1.0 mg/mL, and stored at 4 ° C for a shelf life of 3 months. 4.9 bromodecyl ester standard intermediate solution. accurately transfer 1mL standard stock solution to a 10mL volumetric flask, dilute to the scale with n-hexane A standard solution with a concentration of 100 μg/mL is now available. 4.10 Matrix standard working solution. Add a certain volume of bromohydrazide standard solution to the appropriate amount of sample blank matrix extract and mix. Formulated as a matrix standard working solution. The matrix standard working solution should be ready for use. 4.11 Graphitized carbon-amino solid phase extraction column. Graphitized carbon and aminopropyl filler each 0.5g, 6mL, or equivalent. 4.12 anhydrous sodium sulfate column. 7.5 cm × 1.5 cm (id) glass column, containing 5 cm high anhydrous sodium sulfate. 4.13 Organic phase filter. 0.45 μm.

5 Instruments and equipment

5.1 Gas Chromatograph. equipped with an electron capture (ECD) detector.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 0192-2017_English be delivered?

Answer: Upon your order, we will start to translate SN/T 0192-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 0192-2017_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 0192-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 0192-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0192-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.