BASIC DATA
Standard ID JJG 98-2019 (JJG98-2019)
Description (Translated English) (Verification Regulation of Mechanical Balance)
Sector / Industry Metrology & Measurement Industry Standard
Older Standard (superseded by this standard) JJG 98-2006
Regulation (derived from) State Administration of Market Supervision and Administration Announcement No. 40 of 2019

JJG 98-2019
(Verification Regulation of Mechanical Balance)
National Measurement Verification Regulations of the People's Republic of China
Mechanical balance
2019-09-27 release
2020-03-27 Implementation
Issued by the State Administration of Market Supervision and Administration
Verification Regulation of Mechanical Balance
Replace JJG 98-2006
Focal point. National Technical Committee for Mass Density Measurement
Main drafting unit. Guizhou Metrology and Testing Institute
Zhejiang Academy of Metrology
Shanghai Tianmei Tianping Instrument Co., Ltd.
Participated in the drafting unit. Tianjin Academy of Metrology Supervision and Inspection Science
Shaanxi Provincial Institute of Metrology
Jilin Institute of Metrology
The National Technical Commission for Mass Density Measurement is entrusted to explain this regulation
The main drafters of this regulation.
Gu Xi (Guizhou Metrology and Testing Institute)
Ge Rui (Zhejiang Institute of Metrology)
Dong Li (Shanghai Tianmei Balance Instrument Co., Ltd.)
Participating drafters.
Mo Yihua (Guizhou Metrology and Testing Institute)
Huang Aijun (Tianjin Metrology Supervision and Inspection Science Research Institute)
Guo Xinyu (Shaanxi Provincial Institute of Metrology)
Fuxin (Jilin Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (2)
4 Overview (2)
5 Measurement performance requirements (2)
5.1 Accuracy class (2)
5.2 Balance measurement performance (3)
6 General technical requirements (5)
6.1 Appearance requirements (5)
6.2 Structural requirements (5)
7 Control of measuring instruments (6)
7.1 Verification conditions (6)
7.2 Verification items (7)
7.3 Verification method (8)
7.4 Processing of verification results (16)
7.5 Verification period (16)
Appendix A Calibration record format for double-disc balances (17)
Appendix B Calibration record format for single-disk balances (18)
Appendix C Recording Format of the Error Verification of Hanging Weight Combination (19)
Appendix D. Internal page format of the verification certificate (differential scale or digital scale balance) (22)
Appendix E. Internal page format of verification certificate (ordinary scale balance) (23)
Appendix F. Internal page format of the verification certificate (single-plate balance) (24)
introduction
The accuracy level and terminology of this regulation are referred to the international recommendations of the International Organization for Legal Metrology (OIML)
R76-1 "Non-automatic Weighing Instruments" (Non-automaticWeighingInstruments)
Content. This regulation replaces JJG 98-2006.Compared with JJG 98-2006, the main technical changes except for editorial changes
as follows.
--- Added an introduction;
--- Added reference file;
--- Added terms and units of measurement;
--- Removed working environment conditions;
--- Increasing the applicability requirements in the general technical requirements;
--- Added the calculation formula of "Damping Reduction Coefficient";
--- Added "Inner Page Format of Certification Certificate (Single Plate Balance)";
--- Change "Verification scale division value" to "Verification division value" and "Verification scale division number" to "Verification
Number of divisions";
--- Change "average scale value of left and right plates of empty scale" to "scale scale value of balance of empty scale", "average score of left and right plates of full scale
"Degree value" changed to "full scale balance scale value";
--- Deleted content related to type evaluation;
--- Removed "When mAj≤
5mP
, Y is ignored; when mAj≥
5mP
Time, its impact should be considered";
--- Change "standard weight correction value K*Bj" to "standard weight correction value mccBj", "repair of hanging weight combination
The positive value K*Aj" is changed to "the correction value mccAj of the combination of hanging weights".
The previous releases of this regulation are.
---JJG 98-2006;
---JJG 98-1972.
Verification Regulation of Mechanical Balance
1 Scope
This regulation applies to the first verification, follow-up verification and in-use inspection of lever-type mechanical balances.
2 Reference documents
This regulation refers to the following documents.
JJG 99 weight
JJF1001 General Measurement Terms and Definitions
JJF1229 Terms and Definitions of Mass Density Measurement Terms
GB/T 25107 mechanical balance
OIMLR76 Non-automatic Weighting Instruments
For dated references, only the dated versions are applicable to this Regulation; for those without dates
The latest version (including all amendments) is applicable to this regulation.
3 Terms and units of measurement
3.1 Terminology
The terminology used in this procedure is consistent with the terminology of JJF1229.
The following terms.
3.1.1 Double pan balance
Balance with two weighing pans.
3.1.2 Single pan balance singlepanbalance
Mechanical balance with only one weighing pan.
3.1.3 Hanging weight dialweight
Installed inside the mechanical balance and act on the fixed lever arm, increase or decrease from the outside with the help of the weight dial system
Weights.
3.1.4 Rider
A movable weight mounted on the balance beam or on a graduated scale connected to the beam.
3.1.5 chaincode chainweight
The weight of the mass value is reproduced in the form of a metal chain.
3.1.6 Differential scale subdivisionscaledivision
In electro-optical analysis balances, the indicator scale that indicates and accurately resolves the position through the optical system.
3.1.7 Subdivision reading device
The auxiliary reading device of the differential scale is used to improve the resolution of the balance display value.
3.1.8 turningpoint
In an ordinary scale balance, the position where the swing direction of the balance pointer changes during weighing.