HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 834-2006 English PDF

US$449.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 834-2006: Verification Regulation of Dynamical Signal Analyzer
Status: Valid

JJG 834: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 834-2006English449 Add to Cart 3 days [Need to translate] Verification Regulation of Dynamical Signal Analyzer Valid JJG 834-2006
JJG 834-1993English559 Add to Cart 4 days [Need to translate] Verification Regulation of Dynamic Signal Analyzer Obsolete JJG 834-1993

PDF similar to JJG 834-2006


Standard similar to JJG 834-2006

GB/T 36126   JJG 797   GB/T 1885   JJG 159   JJG 126   JJG 831   

Basic data

Standard ID JJG 834-2006 (JJG834-2006)
Description (Translated English) Verification Regulation of Dynamical Signal Analyzer
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 17,127
Date of Issue 2006-09-06
Date of Implementation 2007-03-06
Older Standard (superseded by this standard) JJG 834-1993
Quoted Standard GB/T 2298-1991
Regulation (derived from) China Measurement 2006. 11
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the following analysis of the frequency range of 200kHz FFT Dynamic Signal Analyzer initial verification, testing and use of follow-up inspection.

JJG 834-2006: Verification Regulation of Dynamical Signal Analyzer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Dynamical Signal Analyzer National Metrology Verification Regulations of the People's Republic Dynamic signal analyzer Released on.2006-09-06 2007-03-06 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Dynamic signal analyzer verification procedure SignalAnaly Replace JJG 834-1993 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 6,.2006, and since.2007. It will take effect on March 6th. Focal Point. National Vibration Shock Velocity Measurement Technical Committee Main drafting unit. 704 Institute of China Aviation Industry First Group Corporation Participated in the drafting unit. China Institute of Metrology Beijing Aerospace University This regulation entrusts the National Vibration Shock Velocity Measurement Technical Committee to explain The main drafters of this procedure. Zeng Wu (The 704 Institute of China Aviation Industry First Group Corporation) Hong Baolin (The 704 Institute of China Aviation Industry First Group Corporation) Participate in the drafters. Xu Yin (China Institute of Metrology) Li Chuanri (Beijing University of Aeronautics and Astronautics)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Metrology performance requirements (1) 4.1 Frequency indication and frequency resolution error (1) 4.2 Spectrum amplitude indication error (1) 4.3 Dynamic Range (1) 4.4 Channel Consistency (2) 4.5 Power spectral density indication error (2) 4.6 Autocorrelation function amplitude indication (2) 4.7 Amplitude linearity (2) 4.8 window function (2) 4.9 Probability density curve or probability distribution curve (3) 4.10 Transient Capture (3) 5 General technical requirements (3) 5.1 Appearance (3) 5.2 Technical indicators to be given by the manufacturer (3) 6 measuring instrument control (3) 6.1 Verification conditions (3) 6.2 Verification project (3) 6.3 Verification method (4) 6.4 Processing of verification results (10) 6.5 Verification cycle (10) Appendix A Calibration Certificate Page Format (11) Appendix B Sinusoidal Waveform Probability Density, Probability Distribution Curve (12) Dynamic signal analyzer verification procedure

1 Scope

This procedure is applicable to the first verification and follow-up of FFT dynamic signal analyzers with an analysis frequency range below.200 kHz. Verification and in-use inspection.

2 Citations

GB/T 2298-1991 Mechanical Vibration and Shock---Glossary When using this procedure, care should be taken to use the current valid version of the above cited documents.

3 Overview

The FFT dynamic signal analyzer (hereinafter referred to as the analyzer) is composed of hardware and analysis software, and can be represented from An instrument that analyzes its characteristic parameters in a physical quantity of electrical signals, which can analyze the measured signal from the time domain, the frequency domain, and the amplitude domain. It is widely used in features such as full function, fast analysis speed, many measurement parameters, high frequency resolution and high amplitude accuracy. Measurement and analysis of mechanical quantities such as vibration and shock.

4 Metrological performance requirements

4.1 Frequency indication and frequency resolution error In the operating frequency range of the analyzer, the frequency indication and frequency resolution error shall comply with the requirements of Table 1. Table 1 Frequency indication and frequency resolution error Frequency indication and frequency resolution error Class A B ±0.01% ±0.1% 4.2 Spectrum amplitude indication error In the operating frequency range of the analyzer, the spectral amplitude indication error shall comply with the requirements of Table 2. Table 2 Spectrum amplitude indication error Spectral amplitude indication error Class A B ±2% ±5% 4.3 Dynamic range The analyzer dynamic range (FFT) should be in accordance with Table 3.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 834-2006_English be delivered?

Answer: Upon your order, we will start to translate JJG 834-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 834-2006_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 834-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 834-2006?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 834-2006 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.