Chinese Standards Shop Partner of Google-Books Database: 169760 (Oct 19, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

JJG 815-2018

Search Result of Chinese Standard: 'JJG 815-2018'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
JJG 815-2018English319 Add to Cart Days<=4 Taking Blood Electronic Scales Valid JJG 815-2018
JJG 815-2018Chinese19 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]  

   
Detail Information of JJG 815-2018; JJG815-2018
Description (Translated English): Taking Blood Electronic Scales
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A53
Classification of International Standard: 17.100
Word Count Estimation: 18,131
Date of Issue: 2018-06-25
Date of Implementation: 2018-12-25
Older Standard (superseded by this standard): JJG 815-1993
Quoted Standard: JJG 99; JJF 1181
Drafting Organization: Shandong Institute of Metrology
Administrative Organization: National Weighing Instrumentation Technical Committee
Regulation (derived from): State Administration of Markets, Announcement No. 13 of 2018
Issuing agency(ies): State market supervision and administration
Summary: This standard applies to the first verification, subsequent verification and in-use inspection of blood collection electronic scales (hereinafter referred to as scales).


JJG 815-2018
Taking Blood Electronic Scales
National Metrology Verification Regulations of the People's Republic
Blood collection electronic scale
Published on.2018-06-25
2018-12-25 implementation
State Administration of Markets issued
Blood collection electronic scale verification procedures
VerificationRegulationof
􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣
􀥣
􀥣
􀥣
􀥣
􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣
􀥣
􀥣
􀥣
􀥣
􀧣 􀧣
􀧣􀧣
Replace JJG 815-1993
Focal Point. National Weighing Instrumentation Technical Committee
Main drafting unit. Shandong Institute of Metrology
Baotou City Product Quality Measurement and Inspection Institute
Zhejiang Institute of Metrology
Participated in the drafting unit. Suzhou Metrology and Testing Institute
Suzhou Medical Instrument Factory
Ankang Quality and Technical Inspection and Testing Center
This regulation entrusts the National Weighing Instrumentation Technical Committee to explain
The main drafters of this procedure.
Liu Ping (Shandong Institute of Metrology)
Feng Xianghui (Baotou City Product Quality Measurement and Inspection Institute)
Shang Xianping (Zhejiang Institute of Metrology)
Participate in the drafters.
Yang Pusheng (Baotou City Product Quality Measurement and Inspection Institute)
Dong Chenguang (Suzhou Metrology and Testing Institute)
Yang Duan Duan (Suzhou Medical Instrument Factory)
Wang Bin (Ankang Quality and Technical Inspection and Testing Center)
table of Contents
Introduction (II)
1 range (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (1)
4 Overview (1)
5 Metrological performance requirements (1)
5.1 Classification of Accuracy Levels (1)
5.2 Verification of the division value (2)
5.3 Maximum allowable error (2)
5.4 Repeatability (2)
5.5 eccentric load (2)
5.6 Identification threshold (2)
5.7 Zero accuracy and peeling accuracy (if applicable) (2)
6 General technical requirements (3)
6.1 Identification of measuring instruments (3)
6.2 Swing frequency (3)
6.3 Alarm function (3)
7 Measuring instrument control (3)
7.1 Standard equipment for verification (3)
7.2 Verification conditions (3)
7.3 Verification project (3)
7.4 Inspection of general technical requirements (4)
7.5 Metrological Performance Verification (4)
7.6 Processing of verification results (8)
7.7 verification period (8)
Appendix A Verification Record Format (Recommended) (9)
Appendix B Verification certificate page format (recommended) (12)
Appendix C Format of the end of the verification result notice (recommended) (13)
introduction
This regulation is a revision of the JJG 815-1993 "Electronic Blood Collection Scale" verification procedures.
This procedure refers to the measurement performance requirements and general technical requirements of JJG 539-2016, and is executed on the format.
JJF1002-2010 "Rules for the preparation of national metrological verification procedures". Compared with JJG 815-1993, except for editorial repair
In addition, there are mainly the following differences.
--- Added terms related to metrological verification (see 3.1.1);
--- specifies the legal unit of measurement that must be used for blood collection scales (see 3.2);
---Modified the relationship between the accuracy level of the scale and the verification division value, the verification division number and the minimum weighing amount (see
5.1);
---Modified the maximum allowable error of the blood collection electronic scale (see 5.3);
--- Modified the swing frequency of the scale (see 6.2);
--- Added a list of verification items (see 7.3);
--- Modified the verification load and verification method of weighing (see 7.5.7);
--- Increased the accuracy of the peeling (if applicable) and the weighing test after peeling (if applicable) (see 7.5.8,
7.5.9);
--- Increased the swing frequency check (see 7.4.2);
--- Dynamic verification is modified to set the alarm value verification (see 7.5.13);
--- Provides the format of the verification record and the verification certificate, and the format of the verification result page (see Appendix A, B,
C).
The previous versions of this procedure were released as follows.
---JJG 815-1993 "Electronic blood collection scale".
Blood collection electronic scale
1 Scope
This procedure is applicable to the first verification, subsequent verification and in-use inspection of blood collection electronic scales (hereinafter referred to as scales).
2 reference files
JJG 99 weight
JJF1181 Weighing Terms and Definitions
For dated references, only the dated version applies to this Code; any undated quotation
The latest version (including all amendments) applies to this procedure.
3 terms and units of measure
3.1 Terminology
The terms defined by JJF1181 and the following terms apply to this procedure.
3.1.1 Maximum allowable setting error maximumpermissiblepresetvalueerror
The maximum allowable difference between the blood collection preset value and the scale value at the time of the alarm.
3.2 Unit of measurement
The unit of measurement used by the scale shall be the legal unit of measurement, gram (g).
4 Overview
The scale is a special non-automatic scale for blood collection and weighing.
Principle. the object is placed on the carrier, and the electrical signal generated by the load cell is converted by the data processing device.
Calculate, the weighing device displays the weighing result, and then converts the weighing result into milliliters through the density conversion function.
The volume value of the bit is displayed.
Structure. The load cell is used as the basic component, with tray, swing mechanism, control circuit, alarm, etc.
Piece of composition.
Uses. Mainly used in blood collection weighing measurement, widely used in blood stations, hospitals and other medical places.
5 Metrological performance requirements
5.1 Division of accuracy levels
The relationship between the accuracy level of the scale and the verification index value, the verification index number and the minimum weighing amount is shown in Table 1.
Related standard:   JJG 808-2014  JJG 993-2018
   
 