US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 813-2013: Verification Regulation of Optical Fiber Power Meter Status: Valid JJG 813: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 813-2013 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Optical Fiber Power Meter
| Valid |
JJG 813-2013
|
JJG 813-1993 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Optical Fiber Power Meter
| Obsolete |
JJG 813-1993
|
PDF similar to JJG 813-2013
Basic data Standard ID | JJG 813-2013 (JJG813-2013) | Description (Translated English) | Verification Regulation of Optical Fiber Power Meter | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A60 | Classification of International Standard | 17.180 | Word Count Estimation | 19,187 | Older Standard (superseded by this standard) | JJG 813-1993 | Quoted Standard | JJG 249-2004; JJG 965-2001 | Regulation (derived from) | ?State AQSIQ Announcement 2013 No. 7 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the first fiber optic power meter test, follow-up test and use checks. |
JJG 813-2013: Verification Regulation of Optical Fiber Power Meter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Optical Fiber Power Meter
State verification procedures People's Republic of China
Fiber Optical Power Meter
Issued on. 2013-01-06
2013-07-06 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Fiber Optical Power Meter Verification Regulation
PowerMeters
Replacing JJG 813-1993
Focal point. the National Technical Committee on Optical metrology
The main drafting units. China Institute of Metrology
Shanghai Measurement and Testing Technology Research Institute
Participated in the drafting. Zhejiang Provincial Institute of Metrology
This procedure committee commissioned by the National Optical measurement technology is responsible for interpreting
The main drafters of this procedure.
Zhang Zhixin (China Institute of Metrology)
Li Jian (China Institute of Metrology)
Xia Ming (Shanghai Institute of Measurement and Testing)
Drafters participate.
Zhou Wen Qing (Zhejiang Institute of Metrology)
Xu Nan (China Institute of Metrology)
Ye Junan (Shanghai Institute of Measurement and Testing)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 units of measurement (1)
4 Overview (1)
5 metering performance requirements (1)
5.1 correction value or correction factor (1)
5.2 Repeatability (2)
5.3 nonlinear (2)
6 General Requirements (2)
6.1 Appearance (2)
6.2 The optical system (2)
7 control of measuring instruments (2)
7.1 verification Conditions (2)
7.2 test items and test methods (3)
7.3 Verification Results Processing (7)
7.4 test cycle (7)
Appendix A Fiber Optical Power Meter Verification original records (8)
Appendix B fiber optic power meter calibration certificate (within the page) format (10)
Appendix C test results Uncertainty Evaluation (12)
Introduction
This procedure based on JJF1002-2010 "national verification procedures to write the rules," while referring to JJG 965-
2001 "communication power meter", JJG 249-2004 "0.1 mW ~ 200 W laser power" and
IEC 61315.2005 "Fiber Power Meter Calibration" (Calibrationoffibre-opticpowermeters), and root
According to the optical fiber power meter related applications in communications, medical, machinery processing, sensing, energy transmission, etc., to
JJG 813-1993 "fiber optic power meter" comprehensive revision. Since JJG 813-1993 "fiber optic power meter"
With the current test procedures to write rules is completely different, and the use of measuring instruments, test content and test method is not a
kind. Therefore, the procedure for JJG 813-1993 "fiber optic power meter" all entries made to replace or increase or decrease.
Fiber Optical Power Meter Verification Regulation
1 Scope
The order applies to optical fiber power meter initial verification, subsequent verification and the use of checks.
2. References
This procedure references the following documents.
JJG 249-2004 0.1mW ~ 200W laser power meter
JJG 965-2001 communicate with power meter
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
Unit 3
Optical power is usually exported manufactured in watts (W) series characterized by international units, engineering general milli dB
(DBm) represents the magnitude of the power. These two units by the formula (1) in terms of.
PdBm = 10lg (PmW/1mW) (1)
Where.
PdBm --- optical power, dBm;
PmW --- optical power, mW.
4 Overview
Fiber optic power meter is used to measure various fiber end face of the output light power instruments. All kinds of fiber optical power is through
One of the main parameters of the optical fiber transmission source and related measuring instruments and optical communication instruments, devices and other products quality evaluation
the amount. PM fiber typically consists of detectors, a signal processing system and a display of three parts. Due to the use of different
Detectors, optical power meter can be divided into the amount of hot type and photoelectric type. Fiber Optic Power Meter calorimeter having a working wavelength range
Wide, flat spectral response, can withstand higher power and other characteristics; but the higher requirements for environmental conditions, and the measurement range compared
Narrow, low sensitivity. Optical Fiber Optic Power Meter has environmental conditions adaptability, wide measuring range, high sensitivity,
Working narrow wavelength range, wavelength selectivity. Both types of fiber optic power meter can be calculated via the display or
Reads optical power.
5 metering performance requirements
5.1 correction value or correction factor
In reference power point, depending on the magnitude of the power light units [value unit conversion by the formula (1). The same below], to
A correction value or correction factor. among them,
Correction value uncertainty. not more than 0.21dB (k = 2), the optical power value in units of dBm;
Correction factor uncertainty. not more than 5% (k = 2), the optical power value in units of W series.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 813-2013_English be delivered?Answer: Upon your order, we will start to translate JJG 813-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 813-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJG 813-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 813-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 813-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|